n

  Wiring the contact signals

  Contact outputs

The ZR802G unit’s four contacts (switches) that can be wired and configured to suit user 

requirements. Contact S4 is programmed as a fail-safe contact. Refer to the User’s Manual IM 

11M12G01-02EN for contact outputs setup.

Use a cable with the rated voltage of 300 V AC or higher and with the electric current capacity 

according to the load connected to contact output.

  Contact inputs

For details, refer to the User’s Manual IM 11M12G01-02EN.

n

  Wiring the mA-input/ output signals

  mA-input signals

The mA-inputs receive current signals of 4-20 mA. Should be used the cable beyond 30 V AC. 

It is necessary to use screening/shielding on the input signal cables. 

For details, refer to the User’s Manual IM 11M12G01-02EN.

  mA-output signals

The output signals consist of current signals of 4-20 mA. The maximum load can be 550 ohms on 

each. Should be used the cable beyond 30 V AC. It is necessary to use screening/shielding on 

the output signal cables. For details, refer to the User’s Manual IM 11M12G01-02EN.

n

  Wiring the sensor

For details, refer to the User’s Manual IM 11M12G01-02EN.

n

  Wiring the communication

The ZR802G can equip Ethernet (Modbus TCP/IP) communication, RS-485 (Modbus RTU) 

communication.

It is necessary to use screening/shielding on the communication cable.

For details, refer to the User’s Manual IM 11M12G01-02EN

1.3 Operation

When all wiring is completed, turn on the power to the instrument. Make sure that the LCD 

screen turns on, and then wait for the Home display appears. If configurations are not proper, an 

error indicator may be displayed, or the measurement values displayed may be incorrect. Check 

the initial settings and change them to suit your purpose.

For details, refer to the following User’s Manual.

Contents

Document number

ZR22G and ZR802G

Separate type Zirconia Oxygen/Humidity Analyzer

IM 11M12G01-02EN

ZR802G and ZR802S

Zirconia Oxygen/Humidity Analyzer, Converter 

HART Communication 

TI 11M12G01-61EN

ZR802G and ZR802S

Zirconia Oxygen/Humidity Analyzer, Converter 

MODBUS Communication

TI 11M12G01-62EN

  Change language

To select a different language, refer to the User’s Manual IM 11M12G01-02EN.

Содержание ZR802G

Страница 1: ...変換器 スタートアップマニュアル IM 11M12G01 01Z1 IM 11M12G01 01Z1 1st Edition This Start up Manual explains mainly the installation and wiring of the ZR802G For detailed information and other information the User s Manual of the ZR802G should be referred to 本書では 主にZR802Gの設置と配線について説明しています 詳細は ZR802Gの取扱説明書を参照ください 本書の日本語説明は 2 1ページ以降をご覧ください ...

Страница 2: ...Wiring and Installation 1 8 1 2 1 Installation site 1 8 1 2 2 Wiring 1 9 1 3 Operation 1 11 1 4 Maintenance 1 12 2 ZR802Gジルコニア式酸素濃度計 高温湿度計 変換器 スタートアップ 安全マニュアル 2 1 はじめに 2 1 安全に使用するための注意事項 2 3 2 1 機器のチェ ッ ク 2 6 2 2 設置 配線 2 7 2 2 1 設置 2 7 2 2 2 配線 2 8 2 3 操作 2 11 2 4 保守 2 11 Revision Information i 1st Edition Mar 08 2021 00 ZR802G Zirconia Oxygen Humidity Analyzer Converter Start up and Safety Precau...

Страница 3: ...Blank Page ...

Страница 4: ...t number is the language code An exclusive User s Manual might be attached to the products whose suffix codes or option codes contain the code Z made to customers specifications Please read it along with this manual Technical Information Contents Document number Note ZR802G and ZR802S Zirconia Oxygen Humidity Analyzer Converter HART Communication TI 11M12G01 61EN Online manual ZR802G and ZR802S Zi...

Страница 5: ...eproduced without prior written consent from YOKOGAWA YOKOGAWA reserves the right to make improvements in the user s manuals and product at any time without notice or obligation If you have any questions or you find mistakes or omissions in the user s manuals please contact our sales representative or your local distributor n Trademark Notices All other company and product names mentioned in this ...

Страница 6: ...nation about the EU Battery Directive This directive is only valid in the EU Batteries are included in this product Batteries incorporated into this product cannot be removed by yourself Dispose them together with this product Battery type Manganese dioxide lithium battery Notice The symbol see above means they shall be sorted out and collected as ordained in the EU Battery Directive n Information...

Страница 7: ...ll instruments in the hazardous area Do not use an abrasive or organic solvent in cleaning the instrument Electrostatic discharge The ZR802G contains devices that can be damaged by electrostatic discharge When servicing this equipment please observe proper procedures to prevent such damage Replacement components should be shipped in conductive packaging Repair work should be done at grounded works...

Страница 8: ...g safety symbols are used on the product as well as in this manual WARNING This symbol indicates that an operator must follow the instructions laid out in this manual in order to avoid the risks for the human body of injury electric shock or fatalities The manual describes what special care the operator must take to avoid such risks CAUTION This symbol indicates that the operator must refer to the...

Страница 9: ... 030 UL UL61010 1 3rd Edition AMD1 UL61010 2 030 1st Edition CSA CAN CSA C22 2 No 61010 1 Amd1 CAN CSA C22 2 No 61010 2 030 GB GB30439 Part 1 EMC CE EN 61326 1 Class ATable 2 EN 61326 2 3 EN 61000 3 2 RCM EN 55011 Class A Group 1 KC KN11 Class A Group1 KN61000 6 2 Note This instrument is a Class A product and it is designed for use in the industrial environment Please use this instrument in the in...

Страница 10: ...tional accessories are sold separately if necessary Make sure the accessories in Table 1 or Table 2 are included Table 1 Standard accessories Iten Q ty Parts No Description Fuse 1 A1113EF Mounting bracket standard 1 F9800AP Bolt for mounting bracket 4 M6x10 mm Washer for mounting bracket 4 for M6 Bolt for pipe mounting 4 M6x70 mm Screws for pipe mounting 2 M6x100 mm Tag label standard 1 Note Note ...

Страница 11: ...e ZR802G is weatherproof and can be installed both inside and outside Construction Equivalent to NEMA 4X IP66 It should however be installed as close as possible to the sensor to avoid long cable runs between the instrument and sensor Select an installation site where the ambient temperature humidity and power voltage are within the limits of the instrument specifications as below If the instrumen...

Страница 12: ... finished wires in the size range of 0 13 to 2 5 sq mm 26 to 14 AWG The cable glands supplied will form a tight seal on cables with an outside diameter of 6 to 12 mm 0 24 to 0 47 inches Unused cable entry holes must be sealed with cable glands including the close up plugs supplied For details refer to the User s Manual IM 11M12G01 02EN n Wiring the power supply CAUTION Make sure the power supply i...

Страница 13: ...d the shield cover Guide the power cables through the gland The terminals will accept wires of 2 5 mm2 14 AWG Always use cable finishings For details refer to the User s Manual IM 11M12G01 02EN l Power supply terminals Connect power supply to the power supply terminals For details refer to the User s Manual IM 11M12G01 02EN AC power terminals l Grounding the converter For the safety of the user an...

Страница 14: ...e screening shielding on the output signal cables For details refer to the User s Manual IM 11M12G01 02EN n Wiring the sensor For details refer to the User s Manual IM 11M12G01 02EN n Wiring the communication The ZR802G can equip Ethernet Modbus TCP IP communication RS 485 Modbus RTU communication It is necessary to use screening shielding on the communication cable For details refer to the User s...

Страница 15: ...correctly fitted when the unit is re assembled in order to maintain the housing s weatherproof integrity against water and water vapor CAUTION Never use harsh chemicals or solvents In the event that the window does become heavily stained or scratched refer to the parts list for replacement part numbers l Battery The ZR802G contains a lithium cell battery to support the clock function when the powe...

Страница 16: ...conia Oxygen Humidity Analyzer Converter Start up and Safety Precautions IM 11M12G01 01Z1 製品添付 紙マニュアル 本書 ZR22G ZR802G ジルコニア式酸素濃度計 高温湿度計 IM 11M12G01 02JA 電子マニュアル ドキュメント番号の Z1 は日本語と英語を併記した言語コードです 形名の基本コードまたは付加コードに Z 特殊仕様 が含まれている製品には 専用の 取扱説明書が付く場合があります その場合 本書に加えて専用の取扱説明書も必ずお 読みください 技術資料 ドキュメント名 ドキュメント番号 備考 ZR802G ZE802S ジルコニア式酸素濃度計 高温湿度計 変換器 HART 通信 TI 12A01F01 61JA 電子マニュアル ZR802G ZR802S ジルコニア式酸素濃度...

Страница 17: ...内容の一部または全部を 無断で転載 複製することは固くお断りいたし ます 説明書の内容については 将来予告なしに変更することがあります 説明書の内容について もしご不審な点や誤り 記載もれなどお気付きのことがあ りましたら 当社の説明書作成部署 当社の営業 またはお買い求め先代理店まで ご連絡ください 図の表記について 説明書に記載されている図では 説明の都合により 強調や簡略化 または一部を省略 していることがあります 説明書中の画面は 機能理解や操作監視に支障を与えない範囲で 実際の表示と表示位 置や文字 大 小文字など が異なる場合があります また 表示されている内容が 表 示例 の場合があります 商標 本文中に使われている会社名 商品名は 各社の登録商標または商標です また本文中の各社の登録商標または商標には TM マークは表示しておりません 製品の廃棄 機器は 地域および国の法律...

Страница 18: ...用しています 警告 製品への表示は 取扱者および機器を重大な事故から保護するために 取扱説明書 を必ず参照する必要がある場所に貼付しています また 取扱説明書への記載の場合 感電事故など 取扱者の生命や身体に危険が及 ぶ恐れがある場合 同時に機器を損傷することもあります その危険を回避する ための注意事項を記述してあります 注意 製品への表示は 取扱者および機器を事故から保護するために 取扱説明書を必ず 参照する必要がある場所に貼付しています また 取扱説明書への記載の場合 取扱者に対し 軽傷事故が発生する恐れがある 場合 または機器を損傷する恐れがある場合に その危険を回避するための注意事 項を記述してあります 以下のシグナルワードやシンボルマークは 取扱説明書にのみ使用しています 注意 ソフトウェアやハードウェアを損傷したり システムトラブルになる恐れがある場 合に 注意すべきことがら...

Страница 19: ...行っていただくか 画面のタッ チパネルで操作を行うようにしてください 対応規格 安全 EMC RoHS その他適合規格 IEC61010 に基づく設置高度 標高 2000 m 以下 IEC61010 に基づくカテゴリー II 注 IEC61010 に基づく汚染度 2 注 注 設置カテゴリーとは 過電圧カテゴリーとも呼ばれ インパルス耐電圧を表します 汚染度とは絶縁耐圧の低下を引き起こす可能性のある固体 液体 気体状物質の存在の程度を示します 安全適合規格 CE EN 61010 1 A1 EN 61010 2 030 UL UL61010 1 3rd Edition AMD1 UL61010 2 030 1st Edition CSA CAN CSA C22 2 No 61010 1 Amd1 CAN CSA C22 2 No 61010 2 030 GB GB30439 Part 1 E...

Страница 20: ...ます 電子マニュアルについては その内容を改ざんできないように PDF のセキュリティを設 定しています プリンタへの出力は可能です 電子マニュアルをプリンタで出力してご使用になる場合は 本製品を利用するためだけ にご使用ください 電子マニュアルをプリンタで出力したものを使う場合 最新版との 不一致が起こらないようご注意ください 電子マニュアルをコピーしたり 第三者に譲渡 販売 頒布 パソコン通信のネットワー クを通じて通信により提供することを含みます することを禁止します また 無断で ビデオテープその他に登録 録画することも禁止します ...

Страница 21: ... 形名コード表は表 3 を参照してください 付属品の確認 表 1 の付属品があることをご確認ください 表1 標準付属品 名称 個数 部品番号 備考 ヒューズ 1 A1113EF 取付けブラケット 標準 1 F9800AP 取付けブラケット用ボルト 4 M6x10 mm 取付けブラケット用ワッシャ 4 M6 用 パイプ取付用ボルト 4 M6x70 mm パネル取付用ねじ 2 M6x100 mm タグラベル 標準 1 注 注 付加コード SCT 指定時以外に付属されます TAGNO 未指定時はブランクのラベルとなります 付加仕様により取付けブランケットは次の表に示すように変わります 表2 付加仕様による取付けブラケット 名称 個数 部品番号 備考 リプレースースブラケット 1 F9800ZA 付加コード BR の場合 リプレースブラケット 重塗装 1 F9800ZC 付加コード BR RC の...

Страница 22: ...ット 分離型で自動校正が必要で 計装用空気が供給されている場合に使用します 電磁弁を標準装備しています 詳細は 取扱説明書 IM 11M12G01 02JA を参照してくだ さい 2 2 設置 配線 前面扉を開き シールドカバーを取り外した状態でケーブルグランドを取り付けてくだ さい 配線が済んだ後は確実にシールドカバーを取り付けてください 詳細は 取扱説明書IM 11M12G01 02JAを参照してください 2 2 1 設置 ZR802G は防雨構造で 屋内外に設置できます 構造 NEMA4X IP66 相当 また で きるだけ検出器の近くに設置して 検出器との間のケーブルが長くならないようにして ください 設置場所の周囲温度および湿度が 必ず以下の範囲内にある場所を選択してください また 屋外設置で直射日光が当たる場合 日除けフードを使用してください 周囲温度 20 55 保管温度 3...

Страница 23: ...源コネクタとヒーター電源への配線を行い 次にその他の 配線を順番に行います 詳細は 取扱説明書 IM 11M12G01 02JA を参照してください 本書では ZR802G を当社製品の検出器と併用する方法について説明しています 配線す る前に お読みください また 本器をご使用になる前に 本書とご使用の検出器に関 する説明書をお読みください 警告 配線には 耐熱性 80 以上のケーブルを使用してください IP66 以上に適合するように配線してください 電源ケーブルは UL2556VW 1 またはそれと同等の規格に適合したケーブルを使用 してください 危険防止のため かつ干渉を避けるため ZR802G の電源端子の上には 必ず端子カ バーを取り付けてください 端子カバー ケーブルグランド 配線口にケーブルグランドを取り付けます 適合ケーブル芯のサイズは 0 13 2 5 mm2 AWG 2...

Страница 24: ...ルや接点出力ケーブル等の電源ラインは ケーブルラック コンジット管 ナイロンバンド等を使用して壁や建造物にしっかりと固定してください ケーブル が引っ張られて端子から外れると感電の恐れがあります 機器を使用する地域の安全規制によっては 外部回路ブレーカの設置が必要なところが あります 地域の規制に従い 必要に応じて設置してください ZR802G は 内部回路の過電流保護のためヒューズによって保護されています ヒューズの定格電流および定格電圧は 電源システムによって異なります IEC60127 に 準拠した 250 VAC timedelay ヒューズを使用してください 警告 ヒューズの交換は 資格を持ったサービス担当者のみが行ってください 2 4 保守 ヒューズを参照してください 端子およびケーブル引き込み口への接続 電源端子はシールドカバーの下にあります 電源ケーブルを ケーブルグランド...

Страница 25: ...ーブルを使用してください 接点信号の配線 接点出力 ZR802G 変換器には接点出力が 4 点あり 使用する環境に合わせて配線 設定することが できます 接点 S4 はフェイルセーフ接点です 定格電圧 300 V AC 以上 接点出力に接続された負荷に応じた電流容量のケーブルを使用 してください 詳細は取扱説明書 IM 11M12G01 02JA を参照してください 接点入力 リモート洗浄サイクル開始またはリモートレンジ開始用の接点流力信号です シールド ケーブルを使用してください 詳細は取扱説明書 IM 11M12G01 02JA を参照してください 電流入力 電流出力の配線 電流入力 入力信号は 4 20 mA の電流信号です 定格電圧 30 V AC 以上のシールドケーブルを使 用してください 詳細は取扱説明書 IM 11M12G01 02JA を参照してください 電流出力 出力信号...

Страница 26: ...ZR802G ZE802S ジルコニア式酸素濃度計 高温湿度計 変換器 HART 通信 TI 11M12G01 61JA ZR802G ZR802S ジルコニア式酸素濃度計 高温湿度計 変換器 MODBUS 通信 TI 11M12G01 62JA 言語の変更 言語を選択する場合は 取扱説明書 IM 11M12G01 02JA を参照してください 2 4 保守 定期保守 ZR802G では 窓の清掃以外は定期保守がほとんど必要ありません 前面窓は清浄に保ち 画面がはっきりと見えるように またタッチパネルの操作が適切にできるようにしてく ださい 汚れた場合は 柔らかい湿った布または柔らかいティッシュで拭いてきれいに してください 頑固な汚れの場合は 中性洗剤を使用してください 前面扉を開けたりケーブルグランドを外して元に戻す際は シール部を清潔にして正し くはめ込み 水や水蒸気に対するケースの...

Страница 27: ...Blank Page ...

Страница 28: ... Converter Start up and Safety Precautions ZR802G ジルコニア式酸素濃度計 高温湿度計 変換器 スタートアップマニュアル Manual No IM 11M12G01 01Z1 Mar 2021 1st Edition Newly published 新版発行 Yokogawa Electric Corporation 2 9 32 Nakacho Musashino shi Tokyo 180 8750 JAPAN http www yokogawa com 横河電機株式会社 180 8750 東京都武蔵野市中町 2 9 32 http www yokogawa co jp ...

Страница 29: ...Blank Page ...

Отзывы: