IM 01C50B01-01E
7-6
7. GENERAL SPECIFICATIONS
[For Explosion Protected Types]
For FOUNDATION Fieldbus explosion protected type, see IM 01C50T02-01E.
CENELEC ATEX (KEMA) Intrinsically safe, Flameproof approval and Type n combination
[Intrinsically safe approval]
Applicable standard: EN 50014, EN 50020, EN 50284 Certificate: KEMA 02ATEX1026X
II 1G EEx ia IIC T4,T5 Ambient Temerature: -40 to 70
°
C for T4, -40 to 50
°
C for T5
Supply/Output circuit: Ui=30V, Ii=165mA, Pi=900mW, Ci=20nF, Li=660
H
Input circuit: Uo=8.6V, Io=30mA, Po=70mW, Co=3
F, Lo=20mH
Electrical Connection: 1/2 NPT female and M20 female*
1
[Flameproof and Dust Ignition Proof Approval]
Applicable Standard: EN 60079-0, IEC 60079-1, EN 61241-0, EN 61241-1
Certificate: KEMA 07ATEX0130
II 2G Ex d IIC T6/T5, II 2D Ex tD A21 IP67 T70
°
C, T90
°
C
Ambient Temperature for Gas Atmospheres: -40 to 75
°
C for T6, -40 to 80
°
C for T5
Ambient Temperature for Dust Atmospheres: -40 to 65
°
C for T70
°
C, -40 to 80
°
C for T90
°
C
Enclosure: IP67
Electrical Connection: 1/2 NPT female and M20 female*
1
[Type n approval]
Applicable standard: EN60079-15
Referential standard: IEC60079-0, IEC60079-11, EN60529:1991
II 3G Ex nL llC T4, T5 Ambient Temperature: -40 to 70
⬚
C for T4, -40 to 50
⬚
C for T5
Supply/Output circuit: Ui=30V, Ci=20nF, Li=660
H
Input circuit: Uo=8.6V, Io=30mA, Po=70mW, Co=3
F, Lo=20mH
Electrical Connection: 1/2 NPT female and M20 female*
1
CENELEC ATEX
(KEMA)
Factory Mutual (FM)
Item
Descriptions
Code
KU2
FM Explosionproof approval
Applicable standard: FM 3600, FM 3615, FM 3810, NEMA250
Explosionproof Class I, Division 1, Groups A, B, C and D;
Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G.
“FACTORY SEALED, CONDUIT SEAL NOT REQUIRED.” Enclosure Rating: NEMA 4X
Temperature Class: T6 Ambient Temperature: -40 to 60
⬚
C (-40 to 140
⬚
F)
Electrical Connection: 1/2 NPT female*
2
FM Intrinsically safe, non-incendive and Explosionproof approval combination*
3
[Intrinsically safe/non-incendive approval]
Applicable standard: FM 3600, FM 3610, FM 3611, FM 3810
Intrinsically safe for Class I, II, III Division 1 Groups A, B, C, D, E, F and G.
Non-incendive for Class I, II, Division 2 Groups A, B, C, D, E, F and G Class III, Division 1.
Enclosure Type: 4X Temperature Class: T4 Ambient Temperature: -40 to 60
⬚
C (-40 to 140
⬚
F)
Supply: Vmax=30V, Imax=165mA, Pmax=0.9W, Ci=18nF, Li=730
H
Sensor: Voc=9V, Isc=40mA, Po=90Mw, Ca=1
F, La=10mH
[Explosionproof approval]
Applicable standard: FM 3600, FM 3615, FM 3810, NEMA250
Class I, Division 1, Groups A, B, C and D.;
Dust-ignitionproof for Class II/III, Division 1, Groups E, F and G.
"FACTORY SEALD, CONDUIT SEAL NOT REQUIRED." Enclosure Ratings: NEMA4X
Temperature Class: T6 Ambient Temperature: -40 to 60
⬚
C (-40 to 140
⬚
F)
Electrical Connection: 1/2NPT female*
2
FF1
FU1
*1 : Applicable for Electrical Connection Code 2 and 4.
*2 : Applicable for Electrical Connection Code 2.
*3 : Not applicable for Output Signal Code F.
T0706-1.EPS
CSA Intrinsically safe, non-incendive and Explosionproof approval combination*
3
[Intrinsically safe/non-incendive approval]
Applicable standard: C22.2 No0, C22.2 No0.4, C22.2 No25, C22.2 No94, C22.2 No142,
C22.2 No157, C22.2 No213 Certificate: 172608-0001053837
Intrinsically safe for Class I, Division 1, Groups A, B, C and D; Class II, Division 1, Groups
E, F and G; Class III, Division 1:
Non-incendive for Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups E,
F and G; Class III, Division 1:
Enclosure Type 4X Temperature Class: T4, Ambient Temperature: -40 to 60
⬚
C,
Supply: Vmax=30V, Imax=165mA, Pmax=0.9W, Ci=18nF, Li=730
H
Sensor input: Voc=9V, Isc=40mA, Po=0.09W, Ca=1
F, La=10mH
Electrical Connection: 1/2 NPT female*
1
[Explosionproof approval]
Applicable standard: C22.2 No0, C22.2 No0.4, C22.2 No25, C22.2 No30, C22.2 No94,
C22.2 No142, C22.2 No157, C22.2 No213, C22.2 No1010.1 Certificate: 1089576
Explosionproof Class I, Div.1, Groups B, C and D, Class II, Groups E, F and G, Class III. For
Class I, Div.2 Locations “FACTORY SEALED, CONDUIT SEAL NOT REQUIRED”
Enclosure Type 4X Temperature Class: T4 Ambient Temperature: -40 to 60
⬚
C
Electrical Connection: 1/2 NPT female*
1
Canadian Standards
Association (CSA)
CU1