YPPA1004 & YPPA1044 Expansion Modules

 

Instruction Manual

 

6

 

INSTALLATION 

There is no need to remove the expansion module from its case 
to complete the installation, wiring, or setup of the unit. 

 

WARNING! 

Do not connect or disconnect the expansion module 
with the power on! 

External Relays & Digital I/O Connections 

The relay and the digital I/O expansion modules YPPA1004 & YPPA1044 
are connected to the meter using a CAT5e cable provided with each 
 module (see Figure 1). 

 

Figure 1:  M-Link Connector Location on the Meter 

 

WARNING!

 

Do not connect any equipment other than Yokogawa’s 
expansion modules, cables, or meters to the RJ45 
M-LINK connector. Otherwise damage will 
occur to the equipment and the meter. 

The two RJ45 connectors on the expansion modules are identical and 
interchangeable; they are used to connect additional modules to the  
system.

 

Note: The jumper located between the RJ45 connectors of the YPPA 

1044 (see Figure 2) must be removed on the second digital  
I/O module in order for the system to recognize it as module #2. 

 

Figure 2:  Jumper Location 

Содержание YPPA1004

Страница 1: ...2 Dart Road Newnan Georgia 30265 770 253 7000 800 888 6400 Fax 770 251 2088 www yokogawa usa com YPPA1004 YPPA1044 Relay I O Expansion Modules Instruction Manual...

Страница 2: ...rs or user settings WARNING Hazardous voltages exist within enclosure Installation and service should be performed only by trained service personnel WARNING Do not connect or disconnect the expansion...

Страница 3: ...s of four 3 amp Form A SPST relays The I O module has four digital inputs and four digital outputs per module External digital inputs can function similarly to the front panel function keys They can b...

Страница 4: ...y supplied cables CONNECTORS RJ45 identical and interchangeable Removable screw terminal blocks that accept 12 to 22 AWG wire TIGHTENING TORQUE Screw terminal connectors 5 lb in 0 56 Nm ENCLOSURE ABS...

Страница 5: ...ond module in order for the system to recognize it as module 2 DIGITAL INPUT LOGIC HIGH 3 to 5 VDC DIGITAL INPUT LOGIC LOW 0 to 1 25 VDC DIGITAL OUTPUT LOGIC HIGH 3 1 to 3 3 VDC DIGITAL OUTPUT LOGIC L...

Страница 6: ...provided with each module see Figure 1 Figure 1 M Link Connector Location on the Meter WARNING Do not connect any equipment other than Yokogawa s expansion modules cables or meters to the RJ45 M LINK...

Страница 7: ...all line voltage connections Observe all safety regulations Electrical wiring should be performed in accordance with all applicable national state and local codes to prevent damage to the meter and en...

Страница 8: ...PDA1004 PDA1044 Expansion Modules Instruction Manual LIM1044YK_A 11 11...

Отзывы: