Setting the MAX Hold Feature
Procedure
Press
SHIFT+CURRENT
(MAX HOLD) to turn the MAX hold feature on and off.
Pressing SHIFT+CURRENT (MAX HOLD) turns the MAX hold feature on and off.
Illuminated
Off
Explanation
MAX Hold
The maximum value that has occurred while the MAX hold feature has been enabled is held. If a value
larger than the currently held value is measured, the larger value is held.
You can hold the following maximum values. The default setting is oFF.
U (voltage), I (current), P (active power), S (apparent power), Q (reactive power), U+pk and U-pk (peak
voltage), I+pk and I-pk (peak current), and P+pk and P-pk (peak power)
• on: The MAX HOLD indicator illuminates, and the MAX hold feature is enabled.
• oFF: The MAX HOLD indicator turns off, and the MAX hold feature is disabled.
Note
The D/A output, communication output, and other values reflect the held maximum values.