9-4
IM 253421-01E
• Setting Preset Integration Time
1.
SHIFT
RESET
INTEG SET
ENTER
3.
Select preset integration time
(Display C)
2.
ENTER
6.
4.
5.
SHIFT
ENTER
9.
7.
8.
ENTER
12.
10.
11.
(Display A)
Hour
Set value
Move across digits
Minute
(Display B)
Second
(Display C)
End
Same as steps 4 and 5
Same as steps 4 and 5
Explanation
D/A Output
Voltage, current, active power, apparent power, reactive power, power factor, phase angle,
harmonic analysis data and integrated data values will be output as a 5V FS analog voltage.
Default Setting of the Output Format
The default items which will be output can be selected as follows.
• dFLt-n (normal measurement values are set as default)
Select this when you want to output normal measurement values. Which items are output
to which channel is described below.
ch1
ch2
ch3
ch4
V
A
W
Hz
Output Channel Output Item
*
*
If either one of the display functions, V Hz or A Hz, is turned on, the frequency of the
corresponding function is output. If both functions are turned OFF, the frequency of the function
that was lighted last will be output.
• dFLt-i (integration measurement values are set as default)
Select this when you want to output integration measurement values. Which items are
output to which channel is described below.
ch1 W
ch2 Wh
ch3 Ah
ch4 Hz
Output Channel Output Item
*
*
If either one of the display functions, V Hz or A Hz, is turned on, the frequency of the
corresponding function is output. If both functions are turned OFF, the frequency of the function
that was lighted last will be output.
Selecting the Desired Item of the Output Format
The items to be output are set per each output channel.
• Setting the output channel
The number of channels is 4. You can select the channel that will output each item.
• Setting the output item (corresponds to column A in the procedure)
The output item can be set to any of the following.
V (voltage), A (current), P (active power), VAr (reactive power), VA (apparent power), PF
(power factor), VFrq (voltage frequency)
*1
, AFrq (current frequency)
*1
, Ph (total Watt-hour
Wh), Ah (total Ampere-hour), dEG (phase angle), VP(peak value of voltage), AP(peak
value of current), MATH(computation), Ph+ (positive watt hour value Wh+), Ph– (negative
watt hour value Wh–), Ah+ (positive ampere hour value
*2
), Ah– (negative ampere hour
value
*2
),
– – – – (D/A output 0 V; no further elements can be set)
*1 If either one of the display functions, V Hz or A Hz, is turned on, the frequency of the
corresponding function is output. If both functions are turned OFF, the frequency of the function
that was lighted last will be output.
*2 For details concerning the positive value of the ampere hour, see page 6-3.
9.3 D/A Output (optional)