14-10
IM 253421-01E
14.3 Commands
14.3.1 Command List
Command
Description
Page
AOUTput Group
:AOUTput?
Queries all settings related to D/A output.
14-14
:AOUTput:CHANnel<x>
Sets/queries the D/A output item.
14-14
:AOUTput:IRTime
Sets/queries the preset integration time for D/A output of integrated values. 14-14
:AOUTput:PRESet
Sets the default value as D/A output items.
14-14
COMMunicateG roup
:COMMunicate?
Queries all settings related to communication.
14-15
:COMMunicate:HEADer
Sets/queries whether a header is to be added.
14-15
:COMMunicate:LOCKout
Sets/cancels local lockout.
14-15
:COMMunicate:REMote
Sets remote/local condition.
14-15
:COMMunicate:STATus?
Queries the status of a specified circuit.
14-15
:COMMunicate:VERBose
Sets/queries the response to be in full or abbreviated form.
14-16
:COMMunicate:WAIT
Waits until one of the specified extended event occurs.
14-16
:COMMunicate:WAIT?
Generates a response when on of the specified extended events occurs.
14-16
CONFigure Group
:CONFigure?
Queries all settings related to the measurement conditions.
14-18
[:CONFigure]:AVERaging?
Queries all settings related to the averaging function.
14-18
[:CONFigure]:AVERaging[:STATe]
Sets/queries averaging ON/OFF.
14-18
[:CONFigure]:AVERaging:TYPE
Sets/queries averaging type and constant.
14-18
[:CONFigure]:CURRent?
Queries all settings related to the current range.
14-18
[:CONFigure]:CURRent:AUTO
Sets/queries the current auto range ON/OFF.
14-18
[:CONFigure]:CURRent:ESCaling?
Queries all settings related to the external sensor.
14-18
[:CONFigure]:CURRent:ESCaling:ELEMent<x>
Sets/queries the scaling constants for the external sensor.
14-18
[:CONFigure]:CURRent:RANGe
Sets/queries the current range.
14-19
[:CONFigure]:FILTer
Sets/queries the filter ON/OFF.
14-19
[:CONFigure]:MHold[:STATe]
Sets/queries the MAX hold function.
14-19
[:CONFigure]:MODE
Sets/queries the measurement mode.
14-19
[:CONFigure]:SCALing?
Queries all settings related to the scaling function.
14-19
[:CONFigure]:SCALing:{PT|CT|SFACtor}?
Queries all settings related to scaling constant for {voltage|current|power}. 14-19
[:CONFigure]:SCALing:{PT|CT|SFACtor}:ELEMent<x>
Sets the scaling constants of {voltage|current|power}.
14-19
[:CONFigure]:SCALing[:STATe]
Sets/queries the scaling function ON/OFF.
14-19
[:CONFigure]:SYNChronize
Sets/queries the measurement synchronization source.
14-19
[:CONFigure]:VOLTage?
Queries all settings related to the voltage range.
14-19
[:CONFigure]:VOLTage:AUTO
Sets/queries the voltage auto range ON/OFF.
14-19
[:CONFigure]:VOLTage:RANGe
Sets/queries the voltage range.
14-20
[:CONFigure]:WIRing
Sets/queries the wiring method.
14-20
DISPlay Group
:DISPlay<x>?
Queries all the display settings.
14-21
:DISPlay<x>:ELEMent
Sets/queries the element to be displayed.
14-21
:DISPlay<x>:FUNCtion
Sets/queries the function to be displayed.
14-21
:DISPlay<x>:MODE
Sets/queries the contents of the display.
14-21
:DISPlay<x>:RESolution
Sets/queries the number of displayed digits.
14-21