![YOKOGAWA vigilantplant YTA Series Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/yokogawa/vigilantplant-yta-series/vigilantplant-yta-series_user-manual_3837085038.webp)
<
7. General Specifications
>
7-2
IM 01C50B01-01E
5 Year Stability
RTD:
±
0.2% of reading or
±
0.2°C,
whichever is greater at 23
±
2°C.
T/C:
±
0.4% of reading or
±
0.4°C,
whichever is greater at 23
±
2°C.
Ambient humidity:
5 to 100%RH at 40°C (104°F)
Effect of supply voltage fluctuation:
±0.005%/V
Insulation:
Input/output insulated at 500 V DC
Mounting:
Mounted on 2B pipes and wall
Degrees of Protection:
IP66/IP67, NEMA 4X
Electrical connection:
Refer to “Model and Specification Codes”.
Case and cover:
Aluminum alloy casting
Painting:
Polyurethane resin baked finish
Deep sea moss green (equivalent of Munsell
0.6GY3.1/2.0)
Integral indicator (option):
LCD digital indicator (5-digit display)
Output bar graph; 0 to 100% display
Damping constant:
0 to 99 seconds (integer range that can be set)
Sensor burnout (Output Signal Code D&E) :
High (110%, 21.6 mA DC) or Low (–2.5%, 3.6
mA DC)
Weight:
1.2 kg; without built-in indicator (without
mounting bracket)
1.4 kg; with Integral indicator (without mounting
bracket)
EMC comformity standard:
EN 61326-1 Class A, Table2 (For use in
industrial locations)
EN 61326-2-3
EN 61326-2-5 (for Fieldbus)
Immunity influence during the test:
Output shift is specified within ±1% of full span.
Material Cross Reference Table
SUS304
AISI 304
SUS316
AISI 316