2-22
IM 701240-01E
• T < T1, T2 < T
A trigger is activated when condition B is met the second time, if the time (T) when
condition B is met the second time is outside a specified time range (T1 to T2).
When condition B: CH1=H, Time1=6
µ
s, and Time2=10
µ
s
B is true
CH1
8
µ
s
8
µ
s
B is true
B is true
12
µ
s
B is true
Trigger
activated
here
CH1
B is true
8
µ
s
8
µ
s
B is true
B is true
4
µ
s
B is true
Trigger
activated
here
Window Trigger
A certain voltage range (window) is set and a trigger is activated when the trigger
source level enters this voltage range (IN) or exits from this voltage range (OUT).
Width
Trigger is activated
OUT
Trigger is activated
IN
Window
Window
Trigger is activated
Center
Width
Center
IN:
Enters the window
OUT: Exits from the window
- :
Don’t care
CH1 to CH16
:
Don’t care
Falling edge
:
Rising edge
Edge trigger is used for the logic input.
LogicA/LogicB
Disable: Do not use logic input
Enable: Use logic input
2.3 Setting the Trigger