<8. EXPLOSION-PROTECTED TYPE INSTRUMENTS>
8-3
IM 01R01B30-00E-E 6th edition October 01, 2014 -00
All Rights Reserved. Copyright © 2003, Rota Yokogawa
8.2 Intrinsically safe ATEX certified RAKD (/KS1)
8.2.1 Technical data
EC-Type Examination Certificate Nr.: KEMA 00ATEX1037X
Used standards:
EN60079-0: 2012
EN60079-11: 2012
The RAKD with electronic transmitter and limit switches is an intrinsically safe device. This device is certified for
hazardous areas of zone 1 (category 2) and zone 2 (category 3). It is not homologated for zone 0 (category 1).
The classifications in brackets are given according to EC- Directive 94/9/EG (ATEX).
Identification in accordance with regulation 94/9/EG (ATEX) :
II 2 G
Data of electronic transmitter type -E :
Type of protection : Intrinsically safe Ex ia IIC T6-T4 Gb
Ambient temperature: -25°C ... +65°C
Safety relevant maximum values:
Supply (current output):
Maximum voltage:
U
i
= 30 V
Maximum current:
I
i
= 100 mA
Maximum power:
P
i
= 750 mW
Inner inductance:
L
i
= 0.73 mH
Inner capacity:
C
i
= 2.4 nF
Pulse output:
Maximum voltage:
U
i
= 16 V
Maximum current:
I
i
= 20 mA
Maximum power:
P
i
= 64 mW
Inner inductance:
L
i
= 0 mH
Inner capacity:
C
i
= 0 nF
Data of limit switches :
Type of protection : Intrinsically safe Ex ia IIC T6 Gb
Safety relevant maximum values:
SC2-NO (/K1.../K3)
SJ2-S.N (/K6.../K10)
Type 2
Type 3
Type 2
Type 3
Maximum voltage:
U
i
= 16 V
16 V
U
i
= 16 V
16 V
Maximum current:
I
i
= 25 mA
52 mA
I
i
= 25 mA 52 mA
Maximum power:
P
i
= 64 mW
169 mW
P
i
= 64 mW 169 mW
Inner inductance
:
L
i
= 0.15 mH
0.15 mH
L
i
= 0.1 mH 0.1 mH
Inner capacity
:
C
i
= 150nF
150nF
C
i
= 30nF
30nF