IM 12B7J1-01E
< 1. Specification >
1-3
1.2
Model and Suffix codes
l
pH Sensor
Model
Suffix Code
Option
Code
Description
PH8EFP
......................................... ...................
KCl Filling Type pH Sensor
Cable Length
and KCl Tube
Length
-03
-05
-07
-10
-15
-20
-V3
-V5
-V7
-VA
-VB
-VC
...................
...................
...................
...................
...................
...................
...................
...................
...................
...................
...................
...................
3 m
5 m
7 m
10 m
15 m
20 m
For Variopin connector 3m (*11)
For Variopin connector 5m (*11)
For Variopin connector 7m (*11)
For Variopin connector 10m (*11)
For Variopin connector 15m (*11)
For Variopin connector 20m (*11)
Solution
Ground Tip
-TN
-HC
...................
...................
Titanium
Hastelloy C
KCl Reserve Tank
(*1)
-TT1
-TT2
-TT3
-TN1
-TN2
...................
...................
...................
...................
...................
For general purpose (250mL solution inlet)
For medium pressure (*2)
Big volume tank (With 500 mL tank)
For maintenance (for TT1, TT3)
For maintenance (for TT2)
-
-N
...................
Always -N
pH Measuring System
-T
-E
-F
-B
-G
-V
...................
...................
...................
...................
...................
...................
For PH200/PH400 (*3)
For PH202/FLXA202/FLXA21 (*4)
For FLXA202/FLXA21 (*10)
For PH100 (*5)
For FLXA402, PH450G,PH202/TB (*9)
Variopin connector (*12)
Style
*A ...................
Style A
Option
O-ring
Special glass electrode
Special junction
/PF
/HA
/TF
Perfluoroelastomer (FFKM) (*6)
Glass electrode for high alkali (*7)
PTFE junction (*8)
*1:
2-inch pipe mounting bracket is supplied with TT1, TT2 and TT3.
Only a supply tube, but no KCl solution, is supplied with TN1 and TN2.
Since a KCl solution is not supplied with TT2, arrange it from among accessories or auxiliary parts.
*2:
Prepare an air pressure regulator as shown in the diagram below when the medium-pressure reserve tank is used.
To pH sensor, Regulator, (to be prepared separately)
Air Supply
To pH sensor
Regulator
(to be prepared separately)
*3:
Mark band is shown by alphanumeric and fork terminals are used.
*4:
Mark band is shown by numeral and pin terminals are used. When terminal box is used, select WTB10-PH1.
*5:
The tag which indicated the color, the sign, and the number is attached to the cable of a sensor.
*6:
Choose Perfluoroelastomer (FFKM) when this is used in organic solvent, high temperature alkaline solution.
*7: Choose when using in high alkali or high temperature alkaline solution.
*8: Choose when using in the heavily contaminated application.
*9: Mark band is shown by numeral and M3 ring terminals are used. When terminal box is used, select WTB10-PH3.
*10: Mark band is shown by numeral and M4 ring terminals are used.
When terminal box is used, select WTB10-PH5.
*11: Select -V for a measuring system.
*12: Option /K (with measurement low certificate) cannot be specified. Do not allow the part above the sensor flange to contact with
the solution.
12th Edition : Dec.14,2018-00