7. LIST OF PARAMETERS
Parameter Display Item
MODEL
Model
TAG NO
Tag no.
SELF CHK
Self-check result
A
DISPLAY1
Display 1
*2
A01
INPUT1
Input value 1
A09
OUTPUT1
Output value 1
A10
OUTPUT2
Output value 2
A15
ALM1 STATUS
Alarm-1 status
A16
ALM2 STATUS
Alarm-2 status
A54
STATUS
Status
*1
A56
REV NO
Rev. no.
A58
MENU REV
MENU REV
A60
SELF CHK
Self-check result
B
DISPLAY2
Display 2
*2
B01
INPUT1
Input value 1
B09
OUTPUT1
Output value 1
B10
OUTPUT2
Output value 2
B15
ALM1 STATUS
Alarm-1 status
B16
ALM2 STATUS
Alarm-2 status
B60
SELF CHK
Self-check result
D
SET (I/O)
Setting (I/O)
*2
D01
TAG NO.1
Tag no. 1
D02
TAG NO.2
Tag no. 2
D03
COMMENT1
Comment 1
D04
COMMENT2
Comment 2
D32
OUT1 L_RNG
Output-1 low range
*3
D33
OUT1 H_RNG
Output-1 high range
*3
D34
OUT2 L_RNG
Output-2 low range
*3
D35
OUT2 H_RNG
Output-2 high range
*3
D41
LINEARIZE
Linearize
D42
LOW CUT
Low cut
D50
OUT1 DR
Direction of output-1 action
D51
OUT2 DR
Direction of output-1 action
D57
S/W FILTER
Software filter
D59
NMRR
Frequency setting
*3
D60
SELF CHK
Self-check result
E
SET(ALM)
Setting (alarm output)
*2
E03
SET POINT1
Alarm-1 setting (%)
E04
SET POINT2
Alarm-2 setting (%)
E05
ALM1 ACTION
Direction of alarm-1 action
E06
ALM2 ACTION
Direction of alarm-2 action
E09
HYSTERESIS1
Alarm-1 hysteresis (%)
E10
HYSTERESIS2
Alarm-2 hysteresis (%)
E11
ON DELAY1
Alarm-1 ON delay setting
E12
ON DELAY2
Alarm-2 ON delay setting
E13
OFF DELAY1
Alarm-1 OFF delay setting
E14
OFF DELAY2
Alarm-2 OFF delay setting
E15
RL1 ACTION
Direction of alarm-1 relay action
E16
RL2 ACTION
Direction of alarm-1 relay action
E60
SELF CHK
Self-check result
F
SET(COM)
Setting (communication)
*2
F01
PROTOCOL
Communication protocol
F02
ADDRESS
Address
F03
BAUD RATE
Baud rate
F04
PARITY
Parity
F05
DATA LEN
Data Length
F06
STOP BIT
Stop bit
F07
INPUT DEC PT
Decimal point position of input
F60
SELF CHK
Self-check result
M
X TABLE
Input breakpoint table
*2
M01
X TABLE
Input breakpoints data
M02
X TABLE
Input breakpoints data
⁞
⁞
⁞
M31
X TABLE
Input breakpoints data
M32
X TABLE
Input breakpoints data
M33 MAX POINT
Number of breakpoints
M60 SELF CHK
Self-check result
N
Y TABLE
Output breakpoint table
*2
N01
Y TABLE
Output breakpoints data
N02
Y TABLE
Output breakpoints data
⁞
⁞
⁞
N31
Y TABLE
Output breakpoints data
N32
Y TABLE
Output breakpoints data
N60
SELF CHK
Self-check result
P
ADJUST
Adjustment
*2
P04
IN1 ZERO ADJ
Zero adjustment of input-1
P05
IN1 SPAN ADJ
Span adjustment of input-1
P30
OUT1ZERO ADJ
Zero adjustment of output-1
P31
OUT1SPAN ADJ
Span adjustment of output-1
P32
OUT2ZERO ADJ
Zero adjustment of output-2
P33
OUT2SPAN ADJ
Span adjustment of output-2
P60
SELF CHK
Self-check result
Q
TEST
Test
*2
Q04 OUT1 TEST
Forced output (output 1)
Q05 OUT2 TEST
Forced output (output 2)
Q10 ALM1 TEST
Forced output (alarm 1)
Q11
ALM2 TEST
Forced output (alarm 2)
Q60 SELF CHK
Self-check result
*1
The Status is displayed for service personnel to see history
records.
*2
There are items not displayed depending on what output-2
is specified.
X TABLE/Y TABLE is displayed when D41:LINEARIZE=ON.
*3
The parameters are the items to be set at the factory.
8. MAINTENANCE
The product starts running immediately when the power is turned
on; however, it needs 10 to 15 minutes of warm-up before it
meets the specified performance.
For cleaning the instrument, use a soft and dry cloth.
8.1 Calibration Apparatus
•
A voltage and current generator (YOKOGAWA GS200 or the
equivalent)
•
A voltmeter (YOKOGAWA 7561 or the equivalent)
•
A precision resistor of 250 Ω ± 0.01%, 1 W (for current output)
•
Setting tool for adjustment (Refer to "4.2 Connector for
Communication" in this manual.)
8.2 Calibration Procedure
1.
Connect the instruments as shown in figure below. First adjust
the output-1 signal and then the output-2 signal.
Power Supply
Output-1 signal
R: For current output using 250
Ω
precision resistor
Voltage and
current
generator
Voltage and
current
generator
Output-2 signal
10
11
3 2 1
4
5
6
7
8
9
11
10
8
L
+
N
–
GND
3
4
+
–
Without SINK current
Input signal
DMM
DMM
DMM
DMM
2
5
R
+
–
1
3
+
–
With SINK current
2
5
Alarm-1 output
Alarm-2 output
ALM1
(NO)
COM
+
–
6
5
ALM2
(NO)
COM
+
–
7
9
R
+
–
2.
Produce input signals equivalent to 0, 25, 50, 75, and 100% of
the input span (or those equivalent to 0, 6.25, 25, 56.25, and
100% of the input span if square root extraction is set) from
the voltage and current generator to the distributor.
3.
Then, check that the distributor’s output signal shows voltages
corresponding to 0, 25, 50, 75, and 100% of the input span
within the rated accuracy range.
For alarm output, check the relay action by the alarm indicator
lamp or resistance of output terminals.
•
When adjusting the output signal, use the VJ77 parameter
setting tool.
For adjustment using a setting tool, refer to the User’s Manual for
setting tool and “7. LIST OF PARAMETERS” in this manual.
User’s Manual for VJ77 [Document No.: IM 77J01J77-01E]
5
IM 77J01A07-01E
5th Edition