4-8
<Toc> <Ind>
<4. Module Access >
IM 34M6H54-01E
•
Output selection
This selects the output type for the comparison results of the counter value with either
preset value 1 or 2, or outputs the counter operating status.
Bit number
Output selection and type
TC040103_03.EPS
9
0
0
0
0
0
0
0
0
0
0
1
8
0
0
0
0
0
0
0
0
0
1
*
7
0
0
0
0
0
0
0
0
1
*
*
6
0
0
0
0
0
0
0
1
*
*
*
5
0
0
0
0
0
0
1
*
*
*
*
4
0
0
0
0
0
1
*
*
*
*
*
3
0
0
0
0
1
*
*
*
*
*
*
2
0
0
0
1
*
*
*
*
*
*
*
1
0
0
1
*
*
*
*
*
*
*
*
0
0
1
*
*
*
*
*
*
*
*
*
Counter value = preset value 1, latched type
Counter value < preset value 1, state type
Counter value
≥
preset value 1, state type
Counter value = preset value 2, latched type
Counter value < preset value 2, state type
Counter value
≥
preset value 2, State type
Preset value 1
≤
counter value < preset value 2, state type
Counter value returns to 0, latched type
Counter operating status (on when stopped), state type
Normally off
Normally on
* Indicates bit position which can be either 0 or 1.
•
Interconnections between output-input channels
For each output channel, this sets the corresponding input channel whose compari-
son result is to be output.
Bit number
Connections to input channel
TC040103_04.EPS
Output
channel
1
2
3
4
14
0
0
0
1
13
0
0
1
*
12
0
1
*
*
Comparison results, etc. of input channel 1
Comparison results, etc. of input channel 2
Comparison results, etc. of input channel 3
Comparison results, etc. of input channel 4
* Indicates position which can be either 0 or 1.
Example setting for the output and output-input channel interconnections
Output-input channel interconnections
Output selection
Setting example
TC040103_05.EPS
Counter value of channel 1 = preset value 1,
latched type output
Counter value of channel 1 < preset value 1, state
type output
Counter value of channel 2 returns to 0, latched
type output
Preset value 1
≤
counter value of channel 3 <
preset value 2, state type
Output channel 1
See Example 1 on the next
page.
Output channel 2
See Example 2 on the next
page.
Output channel 3
See Example 3 on the next
page.
Output channel 4
See Example 4 on the next
page.
Example of the previous settings using a ladder program