6-18
IM80B80T10E
21th Edition : Jul.1,2007-00
< 6.INSTALLATION >
6.7
Switching of Voltage Output Range
Before switching of voltage output range, it is necessary to set the digital switch No.4. (Vide 6.3.3)
The operation procedure is illustrated in the figure below.
At
-5-A4
, press the
F 1
key to select the volt-
age output range setting, the display then changes
to that marked
a
.
The value selected at
a
is '0V to 5V' to change it to
' 1V to 5V', press the
F 2
key. The display then
changes to that marked
b
.
If the
F 1
key is pressed at
b
, the display re-
turns to
a
where '0V to 5V' is selected.
Setting of
Master indicator
-5-A41 a.
Setting of digital SW4
0
1
F1
5V
+Full
0
kt
Output voltage
Ship’s speed
5V
+Full
- Full
kt
0
Output voltage
Ship’s speed
F2
5V
0
1V
+Full
- Full
kt
Output voltage
Ship’s speed
5V
1V
0
+Full
- Full
kt
Output voltage
Ship’s speed
NOTE
Current output is selected automatically as follows.
When selecting 0V to 5V output, current output is set 0 mA to 20 mA.
When selection 1V to 5V output, current output is set 4 mA to 20 mA.
F 1
F 2
DISPL
PREV MODE
F 1
F 2
DISPL
PREV MODE
MAINT
MAINT
F 1
F 2
DISPL
PREV MODE
MAINT
a.
-5-A4
-5-A5
-5-A41
b.
F 1
F 2
DISPL
PREV MODE
F 1
F 2
DISPL
PREV MODE
MAINT
MAINT
F 1
F 2
DISPL
PREV MODE
MAINT
a.
-5-A4
-5-A5
-5-A41
b.