IM 01C25C01-01E
9-11
9. GENERAL SPECIFICATIONS
T0912.EPS
Code
Description
Item
P
Amplifier cover only
Painting
PR
Amplifier cover and terminal cover, Munsell 7.5 R4/14
Color change
X2
Anti-corrosion coating
*
1
Coating change
K1
Degrease cleansing treatment
Oil-prohibited use
AL
Transistor output (open drain: sink type)
Contact rating: 10.5 to 30 V DC, 120 mA DC (max) Low level: 0 to 2 V DC
Status output
*
13
D1
P calibration (psi unit)
Calibration units
*
3
D3
bar calibration (bar unit)
(See table for Span and
Range Limits.)
D4
M calibration (kgf/cm
2
unit)
TF1
Diaphragm protection from sticky process fluid by FEP Teflon film attached with fluorinated oil.
Operation range: 20 to 150
°
C, 0 to 2 MPa (Not applicable for vacuum service).
Teflon film
*
2
*
12
C1
Failure alarm down-scale : Output status at CPU failure and hardware error is
5%,
3.2 mA DC or less.
Output limits
and failure operation
*
4
C2
Failure alarm down-scale : Output status at CPU
failure and hardware error is
5%, 3.2 mA DC or less.
C3
Failure alarm up-scale : Output status at CPU
failure and hardware error is 110%, 21.6 mA or more.
NAMUR NE43 Compliant
Output signal limits : 3.8 mA to
20.5 mA
A1
Inside of isolating diaphragms (fill fluid side) are gold plated, effective for hydrogen permeation.
Gold-plate
*
5
N4
304SST tag plate wired onto transmitter
Stainless steel tag plate
CA
Data configuration for HART communication type
Data configuration at
factory
*
6
CB
Data configuration for BRAIN communication type
Material
certificate
For Flush
type
M0W
High Pressure side: Process flange, Block
*
7
Low Pressure side: Cover flange
M1W
High Pressure side: Process flange, Block
*
8
Low Pressure side: Cover flange, Process connector
M3W
High Pressure side: Process flange, Block, Ring
*
7
*
9
Low Pressure side: Cover flange
M4W
High Pressure side: Process flange, Block, Ring
*
8
*
9
Low Pressure side: Cover flange, Process connector
M0E
High Pressure side: Process flange, Block, Pipe, Base
*
7
Low Pressure side: Cover flange
M1E
High Pressure side: Process flange, Block, Pipe, Base
*
8
Low Pressure side: Cover flange, Process connector
For Extended
type
(Flange rating)
(Test pressure)
Pressure test/Leak test
Certificate
*
14
T51
JIS 10K
2 MPa (290psi)
T54
JIS 20K
5 MPa (720 psi)
T52
ANSI/JPI Class 150
3 MPa (430 psi)
T56
ANSI/JPI Class 300
8 MPa (1160 psi)
*
2
T55
ANSI/JPI Class 300
7 MPa (1000 psi)
*
10
Nitrogen (N
2
) Gas
*
11
Retention time: 10 minutes
K2
Degrease cleansing treatment and with fluorinated oil filled capsule.
Operating temperature
20 to 80
C
K5
Degrease cleansing treatment and dehydrating treatment
Oil-prohibited use
with dehydrating treatment
K6
Degrease cleansing treatment and dehydrating treatment with fluorinated oil filled capsule.
Operating temperature
20 to 80
C
A
Transmitter power supply voltage: 10.5 to 32 V DC ( 10.5 to 30 V DC for intrinsically safe type.)
Allowable current: Max. 6000 A ( 1
40
s ), Repeating 1000 A ( 1
40
s ) 100 times
Applicable Standards: IEC 61000-4-4, IEC 61000-4-5
Lightning protector
Software damping, Descriptor, Message
Software damping
*
1:
Not applicable with color change option.
*
2:
Applicable for flush type (process connection style code
W
.)
*
3:
The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option code
D1
,
D3
, and
D4
.
*
4:
Applicable for output signal code D and E. The hardware error indicates faulty amplifier or capsule.
*
5:
Applicable for wetted parts material code
SW
,
SE
,
WW
,
WE
, and
HW
.
Consult Yokogawa in case gold-plated diaphragm is required for low pressure side.
*
6:
Also see ‘Ordering Information.’
*
7:
Applicable for Low Pressure Side Process connection code
0
and
5
.
*
8:
Applicable for Low Pressure Side Process connection code
1
,
2
,
3
, and
4
.
*
9:
Applicable for flushing connection ring code
A
,
B
,
C
, and
D
.
*
10: Applicable for extended type (process connection style code
E
.)
*
11: Pure nitrogen gas is used for oil-prohibited use (option code
K1
,
2K
,
K5
, and
K6
.)
*
12: Applicable for flushing connection ring code
0
.
*
13: Check terminals cannot be used when this option is specified. Not applicable for output signal code
F and amplifier housing code 2
.
*
14: The unit on the certificate is always MPa regardless of selection of option code
D1
,
D3
, or
D4
.