5-74
IM DLM4038-17EN
:ANALysis:PANalyze<x>:SWLoss:VCE
Function
Sets or queries the collector-emitter saturation
voltage value for total loss
Syntax
:ANALysis:PANalyze<x>:SWLoss:V
CE {<NRf>|<Voltage>}
:ANALysis:PANalyze<x>:SWLoss:VCE?
<x> = 1 to 2
<NRf>, <Voltage> = 0 to 50 V (in 100-mV steps)
Example
:ANALYSIS:PANALYZE1:SWLOSS:VCE 1V
:ANALYSIS:PANALYZE1:SWLOSS:VCE?
-> :ANALYSIS:PANALYZE1:SWLOSS:VCE 1.
000
:ANALysis:PANalyze<x>:TYPE
Function
Sets or queries the type of power supply analysis.
Syntax
:ANALysis:PANalyze<x>:TYPE {HARMonic
s|I2T|OFF|SOA|SWLoss}
:ANALysis:PANalyze<x>:TYPE?
<x> = 1 to 2
Example
:ANALYSIS:PANALYZE1:TYPE HARMONICS
:ANALYSIS:PANALYZE1:TYPE?
-> :ANALYSIS:PANALYZE1:TYPE HARMONIC
S
:ANALysis:PMEAsure<x>?
Function
Queries all power measurement settings.
Syntax
:ANALysis:PMEAsure<x>?
<x> = 1 to 4
Example
:ANALYSIS:PMEASURE1?
-> :ANALYSIS:PMEASURE1
:ANALysis:PMEAsure<x>:IDPRoximal?
Function
Queries all distal, mesial, and proximal settings.
Syntax
:ANALysis:PMEAsure<x>:IDPRoximal?
<x> = 1 to 4
Example
:ANALYSIS:PMEASURE1:IDPROXIMAL?
:ANALysis:PMEAsure<x>:IDPRoximal:MO
DE
Function
Sets or queries the distal, mesial, and proximal
point mode setting.
Syntax
:ANALysis:PMEAsure<x>:IDPRoximal:MO
DE {PERCent|UNIT}
:ANALysis:PMEAsure<x>:IDPRoximal:MO
DE?
<x> = 1 to 4
Example
:ANALYSIS:PMEASURE1:IDPROXIMAL:MO
DE PERCENT
:ANALYSIS:PMEASURE1:IDPROXIMAL:MODE?
-> :ANALYSIS:PMEASURE1:IDPROXIMAL:MO
DE PERCENT
:ANALysis:PMEAsure<x>:IDPRoximal:PER
Cent
Function
Sets or queries the distal, mesial, and proximal
points as percentages.
Syntax
:ANALysis:PMEAsure<x>:IDPRoximal:PER
Cent {<NRf>,<NRf>,<NRf>}
:ANALysis:PMEAsure<x>:IDPRoximal:PER
Cent?
<x> = 1 to 4
<NRf>, <NRf>, <NRf> = 0 to 100 (%, in steps of 1)
Example
:ANALYSIS:PMEASURE1:IDPROXIMAL:PERCE
NT 10,50,90
:ANALYSIS:PMEASURE1:IDPROXIMAL:PERCE
NT?
-> :ANALYSIS:PMEASURE1:IDPROXIMAL:PE
RCENT 10,50,90
:ANALysis:PMEAsure<x>:IDPRoximal:UN
IT
Function
Sets or queries the distal, mesial, and proximal
points as voltages.
Syntax
:ANALysis:PMEAsure<x>:IDPRoximal:UN
IT {<NRf>,<NRf>,<NRf>}
:ANALysis:PMEAsure<x>:IDPRoximal:UN
IT?
<x> = 1 to 4
<NRf>, <NRf>, <NRf> = See the DLM4000
Features Guide for this information.
Example
:ANALYSIS:PMEASURE1:IDPROXIMAL:
UNIT −1,0,1
:ANALYSIS:PMEASURE1:IDPROXIMAL:UNIT?
-> :ANALYSIS:PMEASURE1:IDPROXIMAL:UN
IT −1.000,0.000,
1.000
:ANALysis:PMEAsure<x>:IMEThod
Function
Sets or queries the high and low points.
Syntax
:ANALysis:PMEAsure<x>:IMEThod {AUTO|
MAXimum|HISTogram}
:ANALysis:PMEAsure<x>:IMEThod?
<x> = 1 to 4
Example
:ANALYSIS:PMEASURE1:IMETHOD AUTO
:ANALYSIS:PMEASURE1:IMETHOD?
-> :ANALYSIS:PMEASURE1:IMETHOD AUTO
:ANALysis:PMEAsure<x>:INDicator
Function
Sets or queries the measurement location
indicator.
Syntax
:ANALysis:PMEAsure<x>:INDicator {IAC
|IAVGfreq|…|Z}
:ANALysis:PMEAsure<x>:INDicator?
<x> = 1 to 4
Example
:ANALYSIS:PMEASURE1:INDICATOR IAC
:ANALYSIS:PMEASURE1:INDICATOR?
-> :ANALYSIS:PMEASURE1:INDICATOR IAC
5.3 ANALysis Group