41
IM 701450-61E
TRENd
:
MEASure
<Space>
UPTopeak
UPPeak
UNPeak
UDC
URMS
UA C
UMN
URMN
S
P
Z
Q
LAMBda
WH
WHP
WHN
IPTopeak
IPPeak
INPeak
IDC
IRMS
IAC
IMN
IRMN
AHP
AHN
AH
I2T
?
EXECute
?
?
;
<Standard waveform parameter>
:MATH<x>:HARMonics?
Function
Queries all settings related to the waveform
computation of harmonics.
Syntax
:MATH<x>:HARMonics?
<x> = 1 to 2
Example
:MATH1:HARMONICS? ->
:MATH1:HARMONICS:SPOINT -5.0000000;
VOLTAGE 230;MAXCURRENT 1.000 ;
CLASS C;OPOWER 1;POWER 1.00;
LAMBDA 80.0;DMODE LINEAR
:MATH<x>:HARMonics:CLASs
Function
Sets the applicable class of the equipment
under test or queries the current setting.
Syntax
:MATH<x>:HARMonics:CLASs {A|B|C|D}
:MATH<x>:HARMonics:CLASs?
<x> = 1 to 2
Example
:MATH1:HARMONICS:CLASS C
:MATH1:HARMONICS:CLASS? ->
:MATH1:HARMONICS:CLASS C
:MATH<x>:HARMonics:DMODe
Function
Sets the vertical axis scale mode of the bar
graph or queries the current setting.
Syntax
:MATH<x>:HARMonics:DMODe {LINear|
LOG}
:MATH<x>:HARMonics:DMODe?
<x> = 1 to 2
Example
:MATH1:HARMONICS:DMODE LINEAR
:MATH1:HARMONICS:DMODE? ->
:MATH1:HARMONICS:DMODE LINEAR
12 Communication Commands