5-73
IM 701730-17E
Commands
5
5.17 MEASure Group
:MEASure:{CHANnel<x>|MATH<x>}:
DPRoximal?
Function
Queries all settings related to distal, mesial, and
proximal values of the automated measurement
of waveform parameters.
Syntax
MEASure:{CHANnel<x>|MATH<x>}:
DPRoximal?
<x> of CHANnel <x>=1 to 4 (1 to 2 on the
DL1720E)
<x> of MATH <x>=1 or 2 (1 on the DL1720E)
Example
:MEASURE:CHANNEL1:DPROXIMAL? ->
:MEASURE:CHANNEL1:DPROXIMAL:
MODE PERCENT;
PERCENT 10.0,50.0,90.0;
UNIT -2.000E+00,0.0E+00,2.000E+00
:MEASure:{CHANnel<x>|MATH<x>}:
DPRoximal:MODE
Function
Sets the unit of the distal, mesial, and proximal
values of the automated measurement of
waveform parameters or queries the current
setting.
Syntax
:MEASure:{CHANnel<x>|MATH<x>}:
DPRoximal:MODE {PERCent|UNIT}
:MEASure:{CHANnel<x>|MATH<x>}:
DPRoximal:MODE?
<x> of CHANnel <x>=1 to 4 (1 to 2 on the
DL1720E)
<x> of MATH <x>=1 or 2 (1 on the DL1720E)
Example
:MEASURE:CHANNEL1:DPROXIMAL:
MODE PERCENT
:MEASURE:CHANNEL1:DPROXIMAL:MODE?
-> :MEASURE:CHANNEL1:DPROXIMAL:
MODE PERCENT
:MEASure:{CHANnel<x>|MATH<x>}:
DPRoximal:PERCent
Function
Sets the distal, mesial, and proximal values of
the automated measurement of waveform
parameters in terms of a percentage or queries
the current setting.
Syntax
:MEASure:{CHANnel<x>|MATH<x>}:
DPRoximal:PERCent {<NRf>,<NRf>,
<NRf>}
:MEASure:{CHANnel<x>|MATH<x>}:
DPRoximal:PERCent?
<x> of CHANnel <x>=1 to 4 (1 to 2 on the
DL1720E)
<x> of MATH <x>=1 or 2 (1 on the DL1720E)
<NRf>=0 to 100 (%, 1% steps)
Example
:MEASURE:CHANNEL1:DPROXIMAL:
PERCENT 80,60,40
:MEASURE:CHANNEL1:DPROXIMAL:
PERCENT? -> :MEASURE:CHANNEL1:
DPROXIMAL:PERCENT 80,60,40
:MEASure:{CHANnel<x>|MATH<x>}:
DPRoximal:UNIT
Function
Sets the distal, mesial, and proximal values of
the automated measurement of waveform
parameters in terms of a voltage or current or
queries the current setting.
Syntax
:MEASure:{CHANnel<x>|MATH<x>}:
DPRoximal:UNIT {<voltage>,
<voltage>,<voltage>|<NRf>,<NRf>,
<NRf>}
:MEASure:{CHANnel<x>|MATH<x>}:
DPRoximal:UNIT?
<x> of CHANnel <x>=1 to 4 (1 to 2 on the
DL1720E)
<x> of MATH <x>=1 or 2 (1 on the DL1720E)
<voltage>=8 div on the screen (0.01 div steps)
<NRf>=–4 to 4 div (0.01 div steps)
Example
:MEASURE:CHANNEL1:DPROXIMAL:
UNIT 50V,0V,-50V
:MEASURE:CHANNEL1:DPROXIMAL:UNIT?
-> :MEASURE:CHANNEL1:DPROXIMAL:
UNIT 50.0E+00,0.0E+00,-50.0E+00
Description
When set to the current probe, sets the
<Current> value or queries the current setting.
:MEASure:{CHANnel<x>|MATH<x>}:METHod
Function
Sets the high and low levels of the automated
measurement of waveform parameters or
queries the current setting.
Syntax
:MEASure:{CHANnel<x>|MATH<x>}:
METHod {AUTO|MAXMin}
:MEASure:{CHANnel<x>|MATH<x>}:
METHod?
<x> of CHANnel <x>=1 to 4 (1 to 2 on the
DL1720E)
<x> of MATH <x>=1 or 2 (1 on the DL1720E)
Example
:MEASURE:CHANNEL1:METHOD AUTO
:MEASURE:CHANNEL1:METHOD? ->
:MEASURE:CHANNEL1:METHOD AUTO
:MEASure:{CHANnel<x>|MATH<x>}:
<Parameter> ?
Function
Queries the settings related to the waveform
parameter of the waveform.
Syntax
:MEASure:{CHANnel<x>|MATH<x>}:
<Parameter>?
<x> of CHANnel <x>=1 to 4 (1 to 2 on the
DL1720E)
<x> of MATH <x>=1 or 2 (1 on the DL1720E)
<Parameter>=
{AVERage|AVGFreq|
AVGPeriod|BWIDth1|BWIDth2|DUTYcycle|
FALL|FREQuency|HIGH|LOW|MAXimum|
MINimum|NOVershoot|NWIDth|PERiod|
PNUMber|POVershoot|PTOPeak|
PWIDth|RISE|RMS|SDEViation|TY1Integ|
TY2Integ|XY1Integ|XY2Integ}
Example
(The following is an example for the average
value of CH1.)
:MEASURE:CHANNEL1:AVERAGE? ->
:MEASURE:CHANNEL1:AVERAGE:STATE 1