background image

2

IM 04L4B0-8E

Symbols Used in This Manual

●  Units

•  k: Denotes 1000. Examples: 5 kg, 100 kHz
•  K: Denotes 1024. Example: 640 Kbytes

●  Cautionary notes

In this User's Manual, cautionary notes are distinguished by the following symbols:

   

 

 

Refer to corresponding location on the instrument. This symbol 
appears on dangerous locations on the instrument which require 
special instructions for proper handling or use. The same symbol 
appears in the corresponding place in the manual to identify those 
instructions.

   

 

 

WARNING

Calls attention to actions or conditions that could cause serious 
injury or death to the user, and precautions that can be taken to 
prevent such occurrences.

   

 

 

CAUTION

Calls attentions to actions or conditions that could cause light 
injury to the user or damage to the instrument or user’s data, and 
precautions that can be taken to prevent such occurrences.

Note

 

Calls attention to information that is important for proper operation of 

the instrument.

●  Bold characters

  Denotes key or character string that appear on the DX screen.
  The symbol   indicates the key operation and menu selection procedure on the DX.

 

Содержание Daqstation DX1000

Страница 1: ...User s Manual Y okogawa Electric Corporation DX1000 DX1000N DX2000 EtherNet IP Communication Interface IM 04L41B01 18E 2nd Edition...

Страница 2: ...TCP IP software documents of this product based on BSD Networking Software Release 1 licensed from the University of California Trademarks vigilantplant DAQSTATION Daqstation and DXAdvanced are our r...

Страница 3: ...he manual to identify those instructions WARNING Calls attention to actions or conditions that could cause serious injury or death to the user and precautions that can be taken to prevent such occurre...

Страница 4: ...ley brand The basic items for this configuration are explained For the operation procedures of Rockwell Automation products see the user s manuals of these products This manual is intended for those w...

Страница 5: ...Configuration 8 Explicit Message 9 System Configuration on PLC 9 Data on the DX 12 I O Messages 13 System Configuration on PLC 13 Data on the DX 13 Communication Considerations 14 About Communication...

Страница 6: ...onents Scanner Client A device that launches a request on EtherNet IP This is either a PLC or PC For the DX PLCs such as Allen Bradley PLC 2 PLC 5 SLC 500 MicroLogix CompactLogix and ControlLogix repr...

Страница 7: ...ady to use after the following settings have been made IP address and other settings required to connect to Ethernet Enabling of EtherNet IP server function Access to the DX The DX is a passive device...

Страница 8: ...cation Interface User s Manual IM04L41B01 17E EtherNet IP Server Settings Press MENU to switch to setting mode hold down FUNC for 3 s to switch to basic setting mode and select the Menu tab Communicat...

Страница 9: ...ion tool see the user s manual of the configuration tool EtherNet IP DX Scanner Client Adapter Server PLC Configuration tool Read Write message Ethernet EDS file How to Obtain the EDS File Obtain the...

Страница 10: ...Command name PLC 2 PLC2 Unprotected Read Write PLC 5 PLC5 Word Range Read Write PLC5 Typed Read Write SLC SLC Typed Read Write Specification of data to be accessed Specify which of the data in the DX...

Страница 11: ...F20 59 Communication input data C01 N30 00 L30 00 F30 00 C02 N30 01 L30 01 F30 01 C59 N30 58 L30 58 F30 58 C60 N30 59 L30 59 F30 59 External input channel for writing 201 N40 00 L40 00 F40 00 202 N40...

Страница 12: ...real 1001 47 int 1046 dint 1046 real 1046 48 int 1047 dint 1047 real 1047 Computation channel 101 int 2000 dint 2000 real 2000 102 int 2001 dint 2001 real 2001 159 int 2058 dint 2058 real 2058 160 in...

Страница 13: ...annel Count Number Count Number Count Number Count Number DX1002 2 001 002 12 101 112 24 C01 C24 DX1004 4 001 004 DX1006 6 001 006 24 101 124 DX1012 12 001 012 DX2004 4 001 004 12 101 112 60 C01 C60 D...

Страница 14: ...160 Producer 125 240 4 x 60 FLOAT Communication input data C01 C60 Producer Consumer 130 240 4 x 60 INT32 C01 C60 Producer Consumer 135 240 4 x 60 FLOAT External input channel 201 300 Producer Consume...

Страница 15: ...X Data type to be specified in a command Type Data type INT16 INT32 FLOAT Measurement channel INT16 The data is read without change The data is converted into INT32 including special data The data is...

Страница 16: ...range can be set is from 200 00 to 200 00 A FLOAT value up to two decimal places is rounded to an integer See the example in the following table Input value FLOAT DX value INT16 fixed point 12 34 123...

Страница 17: ...PCCC Data Table 5 Authentication File No 10591 Sep 4 2007 1 A session a framework of connection management in the encapsulation protocol layer of EtherNet IP provides similar functions as a TCP conne...

Страница 18: ...e Ladder Element toolbar to select MSG The MSG block is inserted as ladder output Tag MSG1 is assigned to the MSG block MSG MSG1 EN Message Control Message DN ER Make the MSG block settings Click the...

Страница 19: ...he connection path in the Communication tab is not replaced either I O Configuration Ethernet ETHERNET MODULE DXADV Message Launch Logic Lastly configure the message launch logic In the example shown...

Страница 20: ...ows an example of reading data in measurement channels 001 to 010 and writing the data to communication input data C01 to C20 Data can be accessed using the INT32 type In the Name field enter DXADV or...

Страница 21: ...IP server 7 Ethernet port 7 Explicit message 9 Explicit message example 17 external input channel 9 10 11 H host information 7 I I O message 13 i o message 13 Implicit message 13 installation 8 insta...

Отзывы: