YOKOGAWA ADMAG AXG4A Скачать руководство пользователя страница 5

IM 01E21A21-02EN

 

 

<1.  INTRODUCTION>

3

The following symbols are used in the product and the manual to indicate the accompanying safety 

precautions:

Protective grounding terminal

Functional grounding terminal (This terminal should not be used as a protective grounding terminal.)

Alternating current
Direct current
Caution

This symbol indicates that the operator must refer to an explanation in the user’s manual in order to avoid the risk of injury or 

death of personnel or damage to the product.

•  For the protection and safe use of the product and the system in which this product is incorporated, be 

sure to follow the instructions and precautions on safety that is stated in user's manual as listed in Table 

1.1 whenever you handle the product. Take special note that if you handle the product in a manner that 

violated these instructions, the protection functionality of the product may be damaged or impaired. In such 

cases, YOKOGAWA does not guarantee the quality, performance, function, and safety of product.

•  Do not modify this product.

•  The product should be disposed of in accordance with local and national legislation/regulations.

 Regarding This User’s Manual

•  This manual should be provided to the end user.

•  The contents of this manual are subject to change without prior notice.

•  All rights reserved. No part of this manual may be reproduced in any form without YOKOGAWA’s written 

permission.

•  YOKOGAWA makes no warranty of any kind with regard to this manual, including, but not limited to, 

implied warranty of merchantability and fitness for a particular purpose.

•  If any question arises or errors are found, or if any information is missing from this manual, inform the 

nearest YOKOGAWA sales office.

•  The specifications covered by this manual are limited to those for the standard type under the specified 

model number break-down and do not cover custom-made products.

•  Note that changes in the specifications, construction, or component parts of the product may not 

immediately be reflected in this manual at the time of change, provided that postponement of revisions will 

not cause difficulty to the user from a functional or performance standpoint.

•  To ensure correct use, read this manual and the applicable user’s manuals as listed in Table 1.1 thoroughly 

before starting operation. Read the general specifications as listed in Table 1.1 for its specification.

 Trademark

•  All the brands or names of Yokogawa Electric’s products used in this manual are either trademarks or 

registered trademarks of Yokogawa Electric Corporation.

•  All other company and product names mentioned in this manual are trade names, trademarks or 

registered trademarks of their respective companies.

•  In this manual, trademarks or registered trademarks are not marked with ™ or 

®

.

 For Safe Use of Product

For the protection and safe use of the product and the system in which this product is incorporated, be sure 

to follow the instructions and precautions on safety that is stated in user's manual as listed in Table 1.1 

whenever you handle the product. Take special note that if you handle the product in a manner that violated 

these instructions, the protection functionality of the product may be damaged or impaired. In such cases, 

YOKOGAWA shall not be liable for any indirect or consequential loss incurred by either using or not being able 

to use the product.

Содержание ADMAG AXG4A

Страница 1: ...ADMAG TI Series AXG AXW Magnetic Flowmeter Safety Manual IM 01E21A21 02EN 2nd Edition IM 01E21A21 02EN AXG AXW Magnetic Flowmeter User s Manual ...

Страница 2: ...e 4 2 2 Using this product for an SIS Application 4 2 2 1 Safety Function 4 2 2 2 Safety Accuracy 4 2 2 3 Diagnostic Response Time 4 2 2 4 Setup 5 2 2 5 Required Parameter Setting 5 2 2 6 Proof Test 6 2 2 7 Repair and Replacement 8 2 2 8 Startup Time 8 2 2 9 Firmware Update 8 2 2 10 Reliability Data 8 2 2 11 Lifetime Limits 8 2 2 12 Environmental Limits 8 2 2 13 Application Limits 8 2 3 Definition...

Страница 3: ...First Optional Code EC IM 01E21A11 01EN ADMAG TI Series AXG AXW Magnetic Flowmeter Read Me First IM 01E21A21 01Z1 ADMAG TI Series AXG AXW Magnetic Flowmeter Safely Manual IM 01E21A21 02EN this manual ADMAG TI Series AXG AXW Magnetic Flowmeter BRAIN Communication Type IM 01E21A02 01EN ADMAG TI Series AXG AXW Magnetic Flowmeter HART Communication Type IM 01E21A02 02EN AXG AXG4A AX01C ADMAG TI Series...

Страница 4: ...0 400 For AXW 025 032 040 050 065 080 100 125 150 200 250 300 350 400 For AXW G or AXW W 500 600 700 800 900 10L Precautions Related to the Protection Safety and Alteration of the Product The following safety symbol marks are used in this manual and product WARNING A WARNING sign denotes a hazard It calls attention to procedure practice condition or the like which if not correctly performed or adh...

Страница 5: ... any question arises or errors are found or if any information is missing from this manual inform the nearest YOKOGAWA sales office The specifications covered by this manual are limited to those for the standard type under the specified model number break down and do not cover custom made products Note that changes in the specifications construction or component parts of the product may not immedi...

Страница 6: ...ety Function This product is used as a Type B of Low demand mode in the SIS application F Safety PLC Measuring Device Actuator F0201 ai This product converts Flow velocity Volume flow Mass flow and Flow noise for AXG only to current And it outputs Analog Output 1 at I O 1 terminal as its safety functions Other functions display etc are out of its scope Use this Analog Output 1 to connect the safet...

Страница 7: ...t fail when this product is detected its alarm BRAIN H30 DENSITY SEL HART Menu Path Device root menu Detailed setup Process variables Density Density value select Set this parameter as Fixed value when the Analog Output 1 is used for mass flow measurement BRAIN P22 NEW PASSWORD HART Menu Path Device root menu Detailed setup Protection New password Set a password of 8 characters no lowercase letter...

Страница 8: ...rm and verify that the current value is above 21 6 mA 4 After setting the AO1 alarm out to 2 4 mA via BRAIN or HART communication actually generate an alarm and verify that the current value is less than 2 4 mA 5 Clear the all alarm 6 Return the setting of AO1 Alarm out to the value you noted in Step 2 7 Remove the bypass and otherwise restore normal operation For BRAIN BRAIN configuration tool Fo...

Страница 9: ...Menu Path Device root menu Detailed setup Process variables PV flow select Select Mass above menu An alarm which was set at Analog Output 1 is generated and appeared at the result of above work 2 Set parameters through BRAIN or HART communication protocol in order to generate an alarm at Analog Output 1 by making a condition of scale out at its low limit side of current value BRAIN G04 AO1 ALM OUT...

Страница 10: ...PFDavg calculation of the entire safety instrumentation function according to the SIL to be applied is required When using the transmitter of this flowmeter in a redundant configuration the use of a common cause factor β factor of 5 is suggested If the owner operator of the plant would institute common cause failure training and more detailed maintenance procedures for avoiding common cause failur...

Страница 11: ...onstration for each phase of the life cycle that the output deliverables of the phase meet the objectives and requirements specified by the inputs to the phase The verification is usually executed by analysis and or testing Validation The demonstration that the safety related system s or the combination of safety related system s and external risk reduction facilities meet in all respects the Safe...

Страница 12: ...ual No IM 01E21A21 02EN Edition Date Page Revised Item 1st June 2017 New publication 2nd Feb 2022 1 2 5 6 8 Revise Table 1 1 Document title and No Add IMPORTANT 2 2 5 Add and Revise the explanation 2 2 6 Add and Revise the explanation 2 2 7 2 2 10 and 2 2 11 Add and Revise the explanation Delete SIL declaration and FMEDA report ...

Отзывы: