background image

User's

Manual

USB Compliance 

Test Fixture

Safety Precautions

To ensure safe and correct operation of the fixture, you must take the safety precautions given below. 

The fixture’s protective functions may not work if used in a manner not described in this manual. The 

test fixture is a dedicated instrument for the DL9240/DL9240L. Yokogawa bears no responsibility for, 

nor implies any warranty against damages occurring as a result of failure to take these precautions.

The following safety symbols and wording are used on the test fixture.

  Warning: handle with care. Refer to the user’s manual or service manual. This symbol 

appears on dangerous locations on the instrument which require special instructions for 

proper handling or use. The same symbol appears in the corresponding place in the manual 

to identify those instructions.

  Hot surface

Make sure to comply with the following safety precautions in order to prevent accidents 

such as an electric shock which impose serious health risks to the user and damage to the 

instrument.

 

WARNING

•  To prevent shock or fires, only use the AC adapter and power cable supplied by 

Yokogawa specifically for the test fixture. Also, connect a power supply that meets the 

specifications of the AC adapter.

  Insert the power cable securely into the plug inlet on the AC adapter, and connect the 

output cable securely to the test fixture’s power connector.

 

 

 

 

AC adapter

Test fixture

Output cable

Power connector

Input terminal

Power cable

  Never use an AC adapter or power cable other than the dedicated ones supplied by 

Yokogawa. Using the wrong adapter or cable can result in damage or injury.

  Also, never use the AC adapter that came with the test fixture for any other device.

•  Do not allow any electrically conductive objects to come into contact with the bottom 

surface of the test fixture.

•  Beware of exposed circuits

  Due to the structure of the test fixture, certain components may be exposed. To prevent 

injury, remove all jewelry such as rings and wristwatches. Also, make sure not to touch 

any exposed connectors or components.

•  Never insert your fingers between the metal plates in the center of the test fixture and the 

solder-side of the PCB.

 

CAUTION

•  Do not inadvertently twist or pull the USB cable. The wires inside the cable can break, 

causing malfunction.

•  When shipping or handling, support the test fixture by the center metal plates and avoid 

vibration and shock. Take extra care not to drop the test fixture. Also, never carry the test 

fixture by the USB cable.

•  Due to the structure of the test fixture, certain components may be exposed. Take 

precautions against static electricity when handling.

 

 

 

 

[ INRUSH TEST 

]

[ INIT ]

LED2

CN35

[ DEVICE SQ TEST 

]

DEVICE REC

EIVER

SENSITIVI

TY TEST

CN14 VBUS

GND

GND

VBUS

CN19

CN20

[ TRIGGER 

]

VBUS

CN32

(OFF

)

(50

0 mA

)

SW4

(50

0 mA

)

SW3

BACKDRIV

E

VOL TA

GE TE

ST

[ HOST SQ TEST

 ]

(10

0mA

)

CN11

CN28

CN30

CN29

CN34

CN25

G

D-

D+

G

GND

CN31

LED1

F1

CN100

G

D-

D+

G

CN4

CN2

AVERAGE

CURRENT

DRAW  TESTTP4

TP3

VBUS

VBUS

VBUS

D-

D+

G

CN5

DROOP

TEST

LOAD

TEST

(3)

CN9

(OFF

)

SW1

LOAD

TEST

(1)

CN7

LOAD

TEST

(4)

CN10

(10

0mA

)

SW2

LOAD

TEST

(2)

CN8

G

D-

D+

G

G

D+

D-

G

D-

G

CN16

Metal plate

Hold at the locations 

of the arrows.

Operating environment limitations

See below for operating environment limitations.

 

CAUTION

This product is a Class A (for industrial environments) product. Operation of this product in 

a residential area may cause radio interference in which case the user will be required to 

correct the interference.

Waste Electrical and Electronic Equipment

 

Waste Electrical and Electronic Equipment (WEEE), Directive 2002/96/EC

 

(This directive is only valid in the EU.)

 

This product complies with the WEEE Directive (2002/96/EC) marking requirement. 

This marking indicates that you must not discard this electrical/electronic product in 

domestic household waste.

 

Product Category

 

With reference to the equipment types in the WEEE directive Annex 1, this product is 

classified as a “Monitoring and Control instrumentation” product.

 

Do not dispose in domestic household waste. When disposing products in the EU, 

contact your local Yokogawa Europe B. V. office.

The Following Symbols are Used in this Manual.

 

Improper handling or use can lead to injury to the user or damage to the instrument. 

This symbol appears on the instrument to indicate that the user must refer to the  

user’s manual for special instructions. The same symbol appears in the corresponding 

place in the user’s manual to identify those instructions. In the manual, the symbol is 

used in conjunction with the word “WARNING” or “CAUTION.”

 WARNING 

Calls attention to actions or conditions that could cause serious or fatal injury to the 

user, and precautions that can be taken to prevent such occurrences.

 CAUTION 

Calls attentions to actions or conditions that could cause light injury to the user or 

damage to the instrument or the user’s data, and precautions that can be taken to 

prevent such occurrences.

Note 

Calls attention to information that is important for proper operation of the instrument.

This user’s manual describes handling of the test fixture used for USB compliance tests. For USB 

compliance test procedures, software operating instructions, and other information, please refer to the 

following manuals.

Manual Name

Manual No.

USB Compliance Test Software (busXplorer-USB) User’s Manual

IM701985-61E

Universal Serial Bus 2.0  Device Compliance Test Procedure (CD-ROM) IM701985-62E
Universal Serial Bus 2.0  Host Compliance Test Procedure (CD-ROM)

IM701985-63E

Universal Serial Bus 2.0  Hub Compliance Test Procedure (CD-ROM)

IM701985-64E

For inquiries, please see PIM112-01E (attached).

IM 701985-01E

3rd Edition

1. Checking the Product

  A name plate with the model name is located on the bottom surface (back side) of the test fixture. 

Confirm that the model on the name plate matches that of your order.

MODEL

Model

Suffix Code

Specification

701985

USB Compliance test fixture

Power cord -D

UL/CSA Standard power cord (Part No.:A1068WD)

-F

VDE Standard power cord (Part No.:A1071WD) 

-Q

BS Standard power cord (Part No.:A1069WD)

-R

AS Standard power cord (Part No.:A1070WD) 

Options

/F30

USB compliance software 

/MN1*

Mini B connector type test fixture

*  When the /MN1 option is selected, cable CN25 of the DEVICE RECEIVER SENSITIVITY TEST 

block and cable CN31 of the DEVICE SQ TEST BLOCK will have mini b type connectors.

NO. (Instrument Number)

  Please have this number ready when contacting your Yokogawa representative.

Note

For PC system requirements and other specifications, see “USB Compliance Test Software User’s 

Manual” (IM701985-61E).

2. Product Overview

  The test fixture is used together with the USB compliance test software to perform tests conforming 

to the USB 2.0 compliance test procedures. The fixture consists of separate test blocks for the 

following nine tests: DEVICE SQ TEST, HOST SQ TEST, DEVICE RECEIVER SENSITIVITY TEST, 

TRIGGER, INRUSH TEST, LOAD TEST, DROOP TEST, BACKDRIVE VOLTAGE TEST, AVERAGE 

CURRENT DRAW TEST. The test block used differs depending on the test.

  Waveforms can be observed by probing the measurement pins and waveform measurement 

connectors on the test fixture.

3. Names of Parts

 

CAUTION

•  Take care when handling USB cables and the current measurement loop attached to the 

test fixture. Pulling strongly on cables can cause them to become detached from the test 

fixture.

•  Do not forcefully press the measurement pins and waveform measurement connectors 

on the test fixture.

CN2

CN4

CN11

CN25

CN31

LOAD 

TEST(4)

LOAD 

TEST(3)

TRIGGER

INRUSH 

TEST

LOAD 

TEST(2)

LOAD 

TEST(1)

HOST SQ 

TEST

BACKDRIVE

VOLTAGE TEST

AVERAGE

CURRENT

DRAW TEST

DROOP

TEST

DEVICE SQ TEST

DEVICE 

RECEIVER

SENSITIVITY 

TEST

SW8

LED2

LED3

SW3

SW4

SW5

CN16

SW2

SW1

POWER

LED3

LED1

F1

[ POWER ]

CN100

G D- D+ G

CN4

CN1

CN2

[ HOST SQ TEST ]

AVERAGE

CURRENT

DRAW  TEST

TP4

TP3

VBUS

VBUS

VBUS

D- D+ G

BACKDRIVE

VOLTAGE TEST

CN13

CN20

TP2 TP1

SW5

[DISCHARGE]

[OFF]

[TEST  ON]

G

D-

D+

G

CN17

CN19

VBUS

GND

[INRUSH  TEST]

GN16

G

D-

D+

G

[TRIGGER]

CN11

CN12

CN14

VBUS

GND

CN26

G

D- D+ G

CN15

1

CN28

CN30

D-

CN29

D+

RL1

1

1

1

CN34

RL2

SW8

[TEST]

DEVICE RECEIVER

SENSITIVITY   TEST

CN25

G

D- D+ G

[ I N I T ]

CN32 LED2

CN35

GND

VBUS

[DEVICE  SQ  TEST]

CN31

Receptacle A

Receptacle B

Cable A

Cable B

Power LED

Current measurement loop

4. Usage Precautions

Safety Precautions

•  Do not remove the case

  Do not remove the cover from the top of the test fixture or the case on the bottom. Load resistors 

inside the cover and adjacent components become dangerously hot.

•  In case of abnormalities

  If there are any symptoms of trouble such as strange smells or smoke coming from the test 

fixture or AC adapter, remove the power cord from the outlet immediately.

  If abnormalities occur, please contact your nearest Yokogawa dealer or representative.

•  AC adapter and power cord

  Nothing should be placed on top of the AC adapter or power cord. The AC adapter and power 

cord should also be kept away from heat sources. When removing the power cord plug from the 

outlet, always pull by the plug, never pull by the cord. When removing the AC adapter output 

cable from the test fixture, hold by the plug and pull straight out. Do not pull by the cord. If the 

cord is damaged, contact your dealer for replacement.

General Handling Precautions

•  Do not place anything on top of the test fixture

  Never place other instruments or objects containing water on top of the test fixture.

  Doing so can lead to malfunction.

•  Do not apply shock to the test fixture

  Never apply physical shocks to the connectors, switches, or other components.

  Take proper care when carrying

  Do not hold by the USB cable. Also, hold the test fixture firmly by the center metal plates, and do 

not drop the fixture.

•  Extended periods of non-use

  Remove the power cord from the outlet.

•  Cleaning

  When cleaning, remove the power cord from the outlet, then wipe gently with a soft, dry cloth. 

Also, never immerse the test fixture in liquid, nor use any detergents or abrasives. Do not use 

any volatile solvents such as benzine.

Installation Conditions

  Install the fixture so that the following conditions are met.

•  Flat horizontal location

•  Well ventilated location

•  Place the test fixture on a stable, horizontal surface. Also, always orient the fixture with the 

component side up.

•  Maintain a gap of 10 cm or more on all sides of the test fixture.

 

 

VBUS

VBUS

10 cm or more

10 cm or more

10 cm 

or 

more

10 cm 

or 

more

Do Not Install the Fixture in the Following Places

•  In direct sunlight or near heat sources

•  Where an excessive amount of soot, steam, dust, or corrosive gas is present

•  Near strong magnetic field sources

•  Near high voltages or power lines

•  Location where mechanical vibration is high

•  In an unstable place

•  On an unleveled surface

3rd Edition : December 2008 (YK)
All Rights Reserved, Copyright © 2006, Yokogawa Electric Corporation

IM 701985-01E  3rd Edition  1/2

Отзывы: