User's
Manual
USB Compliance
Test Fixture
Safety Precautions
To ensure safe and correct operation of the fixture, you must take the safety precautions given below.
The fixture’s protective functions may not work if used in a manner not described in this manual. The
test fixture is a dedicated instrument for the DL9240/DL9240L. Yokogawa bears no responsibility for,
nor implies any warranty against damages occurring as a result of failure to take these precautions.
The following safety symbols and wording are used on the test fixture.
Warning: handle with care. Refer to the user’s manual or service manual. This symbol
appears on dangerous locations on the instrument which require special instructions for
proper handling or use. The same symbol appears in the corresponding place in the manual
to identify those instructions.
Hot surface
Make sure to comply with the following safety precautions in order to prevent accidents
such as an electric shock which impose serious health risks to the user and damage to the
instrument.
WARNING
• To prevent shock or fires, only use the AC adapter and power cable supplied by
Yokogawa specifically for the test fixture. Also, connect a power supply that meets the
specifications of the AC adapter.
Insert the power cable securely into the plug inlet on the AC adapter, and connect the
output cable securely to the test fixture’s power connector.
AC adapter
Test fixture
Output cable
Power connector
Input terminal
Power cable
Never use an AC adapter or power cable other than the dedicated ones supplied by
Yokogawa. Using the wrong adapter or cable can result in damage or injury.
Also, never use the AC adapter that came with the test fixture for any other device.
• Do not allow any electrically conductive objects to come into contact with the bottom
surface of the test fixture.
• Beware of exposed circuits
Due to the structure of the test fixture, certain components may be exposed. To prevent
injury, remove all jewelry such as rings and wristwatches. Also, make sure not to touch
any exposed connectors or components.
• Never insert your fingers between the metal plates in the center of the test fixture and the
solder-side of the PCB.
CAUTION
• Do not inadvertently twist or pull the USB cable. The wires inside the cable can break,
causing malfunction.
• When shipping or handling, support the test fixture by the center metal plates and avoid
vibration and shock. Take extra care not to drop the test fixture. Also, never carry the test
fixture by the USB cable.
• Due to the structure of the test fixture, certain components may be exposed. Take
precautions against static electricity when handling.
[ INRUSH TEST
]
[ INIT ]
LED2
CN35
[ DEVICE SQ TEST
]
DEVICE REC
EIVER
SENSITIVI
TY TEST
CN14 VBUS
GND
GND
VBUS
CN19
CN20
[ TRIGGER
]
VBUS
CN32
(OFF
)
(50
0 mA
)
SW4
(50
0 mA
)
SW3
BACKDRIV
E
VOL TA
GE TE
ST
[ HOST SQ TEST
]
(10
0mA
)
CN11
CN28
CN30
CN29
CN34
CN25
G
D-
D+
G
GND
CN31
LED1
F1
CN100
G
D-
D+
G
CN4
CN2
AVERAGE
CURRENT
DRAW TESTTP4
TP3
VBUS
VBUS
VBUS
D-
D+
G
CN5
DROOP
TEST
LOAD
TEST
(3)
CN9
(OFF
)
SW1
LOAD
TEST
(1)
CN7
LOAD
TEST
(4)
CN10
(10
0mA
)
SW2
LOAD
TEST
(2)
CN8
G
D-
D+
G
G
D+
D-
G
D-
G
CN16
Metal plate
Hold at the locations
of the arrows.
Operating environment limitations
See below for operating environment limitations.
CAUTION
This product is a Class A (for industrial environments) product. Operation of this product in
a residential area may cause radio interference in which case the user will be required to
correct the interference.
Waste Electrical and Electronic Equipment
Waste Electrical and Electronic Equipment (WEEE), Directive 2002/96/EC
(This directive is only valid in the EU.)
This product complies with the WEEE Directive (2002/96/EC) marking requirement.
This marking indicates that you must not discard this electrical/electronic product in
domestic household waste.
Product Category
With reference to the equipment types in the WEEE directive Annex 1, this product is
classified as a “Monitoring and Control instrumentation” product.
Do not dispose in domestic household waste. When disposing products in the EU,
contact your local Yokogawa Europe B. V. office.
The Following Symbols are Used in this Manual.
Improper handling or use can lead to injury to the user or damage to the instrument.
This symbol appears on the instrument to indicate that the user must refer to the
user’s manual for special instructions. The same symbol appears in the corresponding
place in the user’s manual to identify those instructions. In the manual, the symbol is
used in conjunction with the word “WARNING” or “CAUTION.”
WARNING
Calls attention to actions or conditions that could cause serious or fatal injury to the
user, and precautions that can be taken to prevent such occurrences.
CAUTION
Calls attentions to actions or conditions that could cause light injury to the user or
damage to the instrument or the user’s data, and precautions that can be taken to
prevent such occurrences.
Note
Calls attention to information that is important for proper operation of the instrument.
This user’s manual describes handling of the test fixture used for USB compliance tests. For USB
compliance test procedures, software operating instructions, and other information, please refer to the
following manuals.
Manual Name
Manual No.
USB Compliance Test Software (busXplorer-USB) User’s Manual
IM701985-61E
Universal Serial Bus 2.0 Device Compliance Test Procedure (CD-ROM) IM701985-62E
Universal Serial Bus 2.0 Host Compliance Test Procedure (CD-ROM)
IM701985-63E
Universal Serial Bus 2.0 Hub Compliance Test Procedure (CD-ROM)
IM701985-64E
For inquiries, please see PIM112-01E (attached).
IM 701985-01E
3rd Edition
1. Checking the Product
A name plate with the model name is located on the bottom surface (back side) of the test fixture.
Confirm that the model on the name plate matches that of your order.
MODEL
Model
Suffix Code
Specification
701985
USB Compliance test fixture
Power cord -D
UL/CSA Standard power cord (Part No.:A1068WD)
-F
VDE Standard power cord (Part No.:A1071WD)
-Q
BS Standard power cord (Part No.:A1069WD)
-R
AS Standard power cord (Part No.:A1070WD)
Options
/F30
USB compliance software
/MN1*
Mini B connector type test fixture
* When the /MN1 option is selected, cable CN25 of the DEVICE RECEIVER SENSITIVITY TEST
block and cable CN31 of the DEVICE SQ TEST BLOCK will have mini b type connectors.
NO. (Instrument Number)
Please have this number ready when contacting your Yokogawa representative.
Note
For PC system requirements and other specifications, see “USB Compliance Test Software User’s
Manual” (IM701985-61E).
2. Product Overview
The test fixture is used together with the USB compliance test software to perform tests conforming
to the USB 2.0 compliance test procedures. The fixture consists of separate test blocks for the
following nine tests: DEVICE SQ TEST, HOST SQ TEST, DEVICE RECEIVER SENSITIVITY TEST,
TRIGGER, INRUSH TEST, LOAD TEST, DROOP TEST, BACKDRIVE VOLTAGE TEST, AVERAGE
CURRENT DRAW TEST. The test block used differs depending on the test.
Waveforms can be observed by probing the measurement pins and waveform measurement
connectors on the test fixture.
3. Names of Parts
CAUTION
• Take care when handling USB cables and the current measurement loop attached to the
test fixture. Pulling strongly on cables can cause them to become detached from the test
fixture.
• Do not forcefully press the measurement pins and waveform measurement connectors
on the test fixture.
CN2
CN4
CN11
CN25
CN31
LOAD
TEST(4)
LOAD
TEST(3)
TRIGGER
INRUSH
TEST
LOAD
TEST(2)
LOAD
TEST(1)
HOST SQ
TEST
BACKDRIVE
VOLTAGE TEST
AVERAGE
CURRENT
DRAW TEST
DROOP
TEST
DEVICE SQ TEST
DEVICE
RECEIVER
SENSITIVITY
TEST
SW8
LED2
LED3
SW3
SW4
SW5
CN16
SW2
SW1
POWER
LED3
LED1
F1
[ POWER ]
CN100
G D- D+ G
CN4
CN1
CN2
[ HOST SQ TEST ]
AVERAGE
CURRENT
DRAW TEST
TP4
TP3
VBUS
VBUS
VBUS
D- D+ G
BACKDRIVE
VOLTAGE TEST
CN13
CN20
TP2 TP1
SW5
[DISCHARGE]
[OFF]
[TEST ON]
G
D-
D+
G
CN17
CN19
VBUS
GND
[INRUSH TEST]
GN16
G
D-
D+
G
[TRIGGER]
CN11
CN12
CN14
VBUS
GND
CN26
G
D- D+ G
CN15
1
CN28
CN30
D-
CN29
D+
RL1
1
1
1
CN34
RL2
SW8
[TEST]
DEVICE RECEIVER
SENSITIVITY TEST
CN25
G
D- D+ G
[ I N I T ]
CN32 LED2
CN35
GND
VBUS
[DEVICE SQ TEST]
CN31
Receptacle A
Receptacle B
Cable A
Cable B
Power LED
Current measurement loop
4. Usage Precautions
Safety Precautions
• Do not remove the case
Do not remove the cover from the top of the test fixture or the case on the bottom. Load resistors
inside the cover and adjacent components become dangerously hot.
• In case of abnormalities
If there are any symptoms of trouble such as strange smells or smoke coming from the test
fixture or AC adapter, remove the power cord from the outlet immediately.
If abnormalities occur, please contact your nearest Yokogawa dealer or representative.
• AC adapter and power cord
Nothing should be placed on top of the AC adapter or power cord. The AC adapter and power
cord should also be kept away from heat sources. When removing the power cord plug from the
outlet, always pull by the plug, never pull by the cord. When removing the AC adapter output
cable from the test fixture, hold by the plug and pull straight out. Do not pull by the cord. If the
cord is damaged, contact your dealer for replacement.
General Handling Precautions
• Do not place anything on top of the test fixture
Never place other instruments or objects containing water on top of the test fixture.
Doing so can lead to malfunction.
• Do not apply shock to the test fixture
Never apply physical shocks to the connectors, switches, or other components.
•
Take proper care when carrying
Do not hold by the USB cable. Also, hold the test fixture firmly by the center metal plates, and do
not drop the fixture.
• Extended periods of non-use
Remove the power cord from the outlet.
• Cleaning
When cleaning, remove the power cord from the outlet, then wipe gently with a soft, dry cloth.
Also, never immerse the test fixture in liquid, nor use any detergents or abrasives. Do not use
any volatile solvents such as benzine.
Installation Conditions
Install the fixture so that the following conditions are met.
• Flat horizontal location
• Well ventilated location
• Place the test fixture on a stable, horizontal surface. Also, always orient the fixture with the
component side up.
• Maintain a gap of 10 cm or more on all sides of the test fixture.
VBUS
VBUS
10 cm or more
10 cm or more
10 cm
or
more
10 cm
or
more
Do Not Install the Fixture in the Following Places
• In direct sunlight or near heat sources
• Where an excessive amount of soot, steam, dust, or corrosive gas is present
• Near strong magnetic field sources
• Near high voltages or power lines
• Location where mechanical vibration is high
• In an unstable place
• On an unleveled surface
3rd Edition : December 2008 (YK)
All Rights Reserved, Copyright © 2006, Yokogawa Electric Corporation
IM 701985-01E 3rd Edition 1/2