2-10
IM 701730-01E
• Width Trigger <For the setup procedure, see section 6.11>
A trigger is activated by determining whether the time width over which the specified
condition is met or not met is shorter or longer than the determination time width set in
advance. The condition is set on the AND logic of the status (High, Low, or Don’t
Care) of each channel or the AND logic of the window condition (IN, OUT, or Don’t
Care) of each channel.
H
L
L
H
H
H
H
L
L
L
H
CH1
CH2
CH1
CH2
L
H
H
L
L
500 ns
300 ns
400 ns
A
B
C
D
450 ns
When the condition is set to CH1 = H, CH2 = L, CH3* = X, CH4* = X, Condition =
True, and Time = 350 ns
Determination Type
Results
Pulse <T
Trigger is activated at point B.
Pulse > T
Trigger is activated at points A and C.
T1 < PLS < T2
When set to Time1 = 350 and Time2 = 450 ns, the trigger activates at
point C.
Time Out
When set to Time1 = 450, the trigger activates at point D.
* CH3 and CH4 not available on the DL1720E.
• OR Trigger <For the setup procedure, see section 6.12>
A trigger is activated when any of the edge or window conditions specified on
channels 1 through 4 are met. For example, a trigger can be activated on the rising
edge of CH1 or CH2.
Condition CH1 = , CH2 =
Triggers
CH1
Triggers
Triggers
CH2
• Window Trigger <For the setup procedure, see section 6.13>
A certain voltage range (window) is set and a trigger is activated when the trigger
source level enters this voltage range (IN) or exits from this voltage range (OUT). This
trigger is used in combination with the OR or Width trigger. The window trigger setting
is located in the OR or Width trigger menu.
Width
Trigger is activated
OUT
Trigger is activated
IN
Window
Window
Trigger is activated
Center
Width
Center
2.3 Triggers