17
VOLTAGE
110/
√
_
3V
110V
115V
120V
220/
√
_
3V
200V
220V
240V
Operating
voltage range
52 to 75V
90 to 130V
104 to 150V
180 to 260V
CURRENT
1A
5A
1A
5A
1A
5A
1A
5A
Single phase 2-wire
LEAD
24 to
LEAD
80var
LAG
LAG
LEAD
120 to
LEAD
400var
LAG
LAG
LEAD
36 to
LEAD
164var
LAG
LAG
LEAD
180 to
LEAD
820var
LAG
LAG
—
—
LEAD
72 to
LEAD
328var
LAG
LAG
LEAD
360 to
LEAD
1640var
LAG
LAG
3-phase 3-wire
—
—
LEAD
62 to
LEAD
285var
LAG
LAG
LEAD
312 to
LEAD
1400var
LAG
LAG
—
—
LEAD
125 to
LEAD
570var
LAG
LAG
LEAD
625 to
LEAD
2850var
LAG
LAG
3-phase 4-wire
LEAD
62 to
LEAD
285var
LAG
LAG
LEAD
312 to
LEAD
1400var
LAG
LAG
LEAD
109 to
LEAD
495var
LAG
LAG
LEAD
545 to
LEAD
2475var
LAG
LAG
LEAD
125 to
LEAD
570var
LAG
LAG
LEAD
625 to
LEAD
2850var
LAG
LAG
LEAD
218 to
LEAD
990var
LAG
LAG
LEAD
1090 to
LEAD
4950var
LAG
LAG
Standard Rating
Available Calibration Varmeters
VARMETERS
[Available Calibration Vars]
Zero-center meter
Available Calibration Varmeters are 33 to 150%. Standard Vars beyond the limits are not available.
Single phase 2-wire : Standard Vars = Voltage Rating
×
Current Rating
3-phase 3-wire : Standard Vars = root3
×
Line Voltage Rating
×
Current Rating
3-phase 4-wire : Standard Vars = 3
×
Phase Voltage Rating
×
Current Rating
Single deflecting meter and Unbalanced scale meter (on the "b"side)
VOLTAGE
110/
√
_
3V
110V
115V
120V
220/
√
_
3V
200V
220V
240V
Operating
voltage range
52 to 75V
90 to 130V
104 to 150V
180 to 260V
CURRENT
1A
5A
1A
5A
1A
5A
1A
5A
Single phase 2-wire
LEAD
48 to
LEAD
80var
LAG
LAG
LEAD
240 to
LEAD
400var
LAG
LAG
LEAD
72 to
LEAD
164var
LAG
LAG
LEAD
360 to
LEAD
820var
LAG
LAG
—
—
LEAD
144 to
LEAD
328var
LAG
LAG
LEAD
720 to
LEAD
1640var
LAG
LAG
3-phase 3-wire
—
—
LEAD
125 to
LEAD
285var
LAG
LAG
LEAD
625 to
LEAD
1400var
LAG
LAG
—
—
LEAD
250 to
LEAD
570var
LAG
LAG
LEAD
1250 to
LEAD
2850var
LAG
LAG
3-phase 4-wire
LEAD
125 to
LEAD
285var
LAG
LAG
LEAD
625 to
LEAD
1400var
LAG
LAG
LEAD
218 to
LEAD
495var
LAG
LAG
LEAD
1090 to
LEAD
2475var
LAG
LAG
LEAD
250 to
LEAD
570var
LAG
LAG
LEAD
1250 to
LEAD
2850var
LAG
LAG
LEAD
430 to
LEAD
990var
LAG
LAG
LEAD
2150 to
LEAD
4950var
LAG
LAG
Standard Rating
Available Calibration Varmeters
Available Calibration Varmeters are 65 to 150%. Standard Vars beyond the limits are not available.
Single phase 2-wire:Standard Vars = Voltage Rating
×
Current Rating
3-phase 3-wire:Standard Vars = root3
×
Line Voltage Rating
×
Current Rating
3-phase 4-wire:Standard Vars = 3
×
Phase Voltage Rating
×
Current Rating
When using VT and CT, Caribration Varmeters will be as follows ;
Caribration Vars =
MAX.Full scale value
(VT ratio)
×
(CT ratio)
EX.1
EX.2
Connection
3-phase
3-wire
Single phase
2-wire
Full scale
value
LEAD 10 to 0 to
LAG 10 kvar
LEAD 3 to 0 to
LAG 3 kvar
VT ratio
660/110V
660/110V
CT ratio
20/5A
20/5A
Calibration Varmeters
FS =
10kvar
=
416.7var Available
660/110
×
20/5
FS =
3kvar
=
125var
660/110
×
20/5
LEAD
LAG
LEAD
LAG
LEAD
LAG
LEAD
LAG
Special order with
TOKUCHU sheet