Yokis MD3300MRP Скачать руководство пользователя страница 4

DS1054-074B

ASSIGNING AN MTR RECEIVER MODULE TO A CHANNEL

 

On the MD3300MRP load manager, access the PARAMETER configuration 
menu by pressing the key

 

 

. The icons

 

 

/

 

 

and “

kW

” will start 

flashing.

 

Press the arrow key

 

 

or 

 until the icons 

 and 

 flash on the 

display. Press the

 

 

key to enter the CHANNEL configuration menu.

 

The device display shows “Add CH”. Press the 

 

key to assign the 

receiver module to the channel.

 

The display shows “

CH N. .8

” where the parameter “

N

” indicates the 

channel number (from 1 to 8) where the assignment to the receiver module 

is made, the parameter 

8

 indicates the maximum number of channels.

 

It is recommended to perform the assignment starting with the 

channels with the highest priority.

  

Urmet S.p.a. – 10154 TORINO (ITALY) – Via Bologna 188/C - For technical information, go to www.yokis.com or call:

Customer Service: +39 011.23.39.810 - export dept. Phone: +39 011.24.00.250/256

 

Press the arrow keys

 

 

or 

 to select the channel “

N

” on which you want 

to perform the assignment. Press the key 

 

to confirm.

 

While “

InProG

” is flashing for 30 seconds, press briefly with a sharp, properly 

insulated tool into the “Connect” hole on the receiver module.

 

The MD3300MRP device will briefly display the message “

PASS

” if the 

assignment of the channel to the receiver module has been successful.

 

If the device displays the message “

Err. 03

” the assignment has not been 

successful. Repeat the operation and make sure to press into the “Connect” 

hole on the receiver module within the 30 seconds in which the MD3300MRP 

load manager displays the message “

InProG

”.

 

It is necessary to repeat the procedure for each receiver module you wish to 

assign to a channel of the MD3300MRP device.

 

It is possible to assign more than one receiver module to each channel. 

In this case, if the absorption threshold is exceeded, there will be two 

or more loads disconnecting at the same time.

REMOVING AN ASSIGNMENT BETWEEN AN MTR RECEIVER MODULE 

AND A CHANNEL

It is possible to remove an assignment between an MTR receiver module and 

a channel of the MD3300MRP device.

 

On the MD3300MRP device, access the PARAMETER configuration menu by 
pressing the key

 

 

. The icons 

 

 

/

 

 

and “

kW

” will start flashing.

 

Press the arrow key 

 or 

 until the icons 

 and 

 flash. Press the key

 

 

to enter the CHANNEL configuration menu.

 

The device display shows “

Add CH

”. Press the arrow keys 

 or 

 until 

dEL CH

” is displayed, press the key 

 

to remove an assignment.

 

InProG

” is displayed.

 

While “

InProG

” is flashing for 30 seconds, press briefly with a sharp, properly 

insulated tool into the “Connect” hole on the receiver module.

 

The MD3300MRP device will briefly display the message “

PASS

” if the 

assignment removal between the channel and the receiver module has been 

successful.

 

If the device displays the message “

Err. 03

” the assignment removal has 

not been successful. Repeat the operation and make sure to press into the 

“Connect” hole on the receiver module within the 30 seconds in which the 

MD3300MRP load manager displays the message “

InProG

”.

 

It is necessary to repeat the entire procedure for each assignment you wish 

to remove.

TEST FUNCTION

The test function is used to check that the assignment between the receiver 

module and the MD3300MRP load manager (i.e. the relevant channel) is 

working correctly. The test involves a switching on and off sequence (one 

every 10 seconds) of the receiver module.

 

On the MD3300MRP load manager, access the PARAMETER configuration 
menu by pressing the key 

  . The icons 

 / 

 and “

kW

” will start 

flashing.

 

Press the arrow key 

 or 

 until the icons 

 and  

 flash on the display. 

Press the key 

 to enter the CHANNEL configuration menu.

 

The device display shows “

Add CH

”. Press the arrow keys 

 or 

 until 

test

” is displayed, press the key 

  to test a channel.

 

The display shows “

CH N. .8

” where the parameter “

N

” indicates the channel 

number (from 1 to 8) where the test is performed, the parameter 

8

 indicates 

the maximum number of channels.

 

Press the arrow keys 

 or 

 to select the channel “

N

” on which you want 

to perform the test. Press 

 to confirm.

 

Every time the command is transmitted, the icon 

  flashes for a few 

seconds while the alarm LED, located between the keys 

 or 

 , shows 

the transmission status:

 

 

LED on = actuation ON 

  LED off = actuation OFF

 

It is possible to interrupt the test by pressing

 

 .

 

The MD3300MRP device briefly displays the message “

PASS

” at the end of 

the test.

11. OPERATING PARAMETER CONFIGURATION MENU

The following operating parameters can be configured through the parameter 

configuration menu:
-  Setpoint (kW)
-  Ton (seconds)
-  Toff (seconds)

 

When a parameter has been configured, the device automatically 

switches to the next parameter configuration. To exit the parameter 
configuration menu, simply press the

 

 key.

 

When configuring parameters, long presses of the arrow key

 

 

or

 

 

allows changing the values more quickly.

 

SETPOINT (kW)

Represents the activation threshold that is to say the maximum value of 

accepted consumption. Over this value the MD3300MRP device provides 

for the disconnection of the lowest priority load that is connected in that 

moment.

 

On the MD3300MRP device, access the PARAMETER configuration menu by 
pressing the

 

 key. The icons 

 / 

 and “kW” will start flashing. Press 

the key

 

 

for Setpoint configuration.

 

On the display, the icons 

 / 

  will be steady on and the Setpoint 

parameter value will start flashing.

 

Press the arrow keys 

 or 

  to set the Setpoint parameter. The 

parameter value can be set in an interval from 

0.8

 kW to 

7

 kW. Press the

 

 

key to confirm and go to the next parameter configuration.

Ton (seconds)

Represents the pre-alarm time, that is to say how long the power must be 

higher than the setpoint before the load is actually disconnected.

 

On the display, the icons 

 / 

 will be steady on and the prealarm time 

value (Ton) will start flashing.

 

Press the arrow keys 

 or 

  to set the prealarm time (Ton). The 

parameter value can be set in an interval from 

10 seconds

 to 

9999 

seconds

.  Press the

 

 

key to confirm and go to the next parameter 

configuration.

Toff (seconds)

Represents the recovery time, that is to say after how long the most priority 

load, disconnected in that moment, is reconnected.

 

 

The load is connected only if the absorbed power is lower than the 

set power threshold.

 

On the display, the icons

 

 / 

 / 

 will be steady on and the alarm 

reset time value (Toff) will start flashing.

 

Press the arrow keys 

 or 

  to set the alarm reset time (Toff). The 

parameter  value can be set in an interval from 

10 seconds

 to 

9999 

seconds

. Press the 

 

key to confirm and exit the configuration menu.

Time

Power

Load disconnection

Setpoint

Ton

Toff

12. ACTIVATION THRESHOLD EXCEEDED

If the absorbed power exceeds the set 
activation threshold (Setpoint), the icon

 

 

the measured value and the red alarm LED will 

start flashing on the device. If the absorbed 

power remains greater than the set activation 

threshold (Setpoint) for a time longer than the 

time set in the prealarm parameter (Ton), the 

MD3300MRP device disconnects the loads 

(one every 5 seconds), starting from that with 

lowest priority (channel 1 = priority 1 = highest 

priority) until the absorbed power falls below 

the activation threshold (Setpoint). Then the 

device provides the loads connection (one 

every 5 seconds) in reverse order, when the 

alarm reset time (Toff) has elapsed.

  

The transmission of commands to radio receivers is shown by the 
lighting of the icon

 

 

on the device display

.

13. ECO OPERATION

By pressing for a long time (3 seconds) the key 

 you can disable the 

control of the control unit MD3300MRP so as to force all loads to remain 

active even if the absorbed power exceeds the set threshold (Setpoint).

 

This condition is indicated by the symbol 

 switch on.

Upon activation, the loads that are disconnected are activated (in sequence 

from the most priority load) every 5 seconds.

To disable the ECO function, press and hold the

 

 

key until the 

 

icon 

turns off.

10. CHANNEL CONFIGURATION MENU (PRIORITY)

Setpoint

Ton

Channel configuration menu

PARAMETER CONFIGURATION MENU

0,8÷7 Kw

10÷9999 s

10÷9999 s

New assignment

Assignment removal

Test

CH N ÷ 8

CH N ÷ 8

Procedure completed

Procedure failed

>2 sec.

>2 sec.

CHANNEL CONFIGURATION MENU

MADE IN FRANCE

2) Assigning the receiver module to the MD3300MRP load manager

 

When the Radio Bus has been created, assign the MTR receiver module 

which pilots the load to the MD3300MRP load manager following the 

procedure described in paragraph “

Radio assignment between an MTR 

receiver module and the MD3300MRP load manager

”.

After performing the RADIO assignment between the receiver modules 

and the MD3300MRP load manager, it is necessary to make the assignment 

between the receiver modules and the device channels, so as to indicate to 

the MD3300MRP load manager which receiver modules are to be piloted 

according to the priorities.

  

The MD3300MRP device is able to manage up to 8 channels, each with 

a different priority: channel 1 = priority 1 = highest priority.

Содержание MD3300MRP

Страница 1: ...onnected If you wish to manage more than 7 modules it is necessary to create a radio bus to allow communication between the MD3300MRP device and the subsequent modules Only one MD3300MRP device can be configured on each system On the MD3300MRP device access the RADIO configuration menu by simultaneously pressing keys and for approx 3 seconds until the display shows bind r1 You can cancel the assig...

Страница 2: ...onnected If you wish to manage more than 7 modules it is necessary to create a radio bus to allow communication between the MD3300MRP device and the subsequent modules Only one MD3300MRP device can be configured on each system On the MD3300MRP device access the RADIO configuration menu by simultaneously pressing keys and for approx 3 seconds until the display shows bind r1 You can cancel the assig...

Страница 3: ...he test 11 OPERATING PARAMETER CONFIGURATION MENU The following operating parameters can be configured through the parameter configuration menu Setpoint kW Ton seconds Toff seconds When a parameter has been configured the device automatically switches to the next parameter configuration To exit the parameter configuration menu simply press the key When configuring parameters long presses of the ar...

Страница 4: ...he test 11 OPERATING PARAMETER CONFIGURATION MENU The following operating parameters can be configured through the parameter configuration menu Setpoint kW Ton seconds Toff seconds When a parameter has been configured the device automatically switches to the next parameter configuration To exit the parameter configuration menu simply press the key When configuring parameters long presses of the ar...

Отзывы: