background image

 

 

 

It is also important to ensure that the employer has a documented rescue plan and has the ability to 

implement it.   

   

3. COMPATIBILITY 

When used as part of a PPE system against falls from a height, this connector must be connected to a 

compatible connection (example: a correct D-Ring).    It is important to ensure compatibility in order to avoid 

possibility of roll-out or disengagement.   

Only one personal protective system can be attached to this connector.    This connector is designed for use 

by one person only.   

Ensure that proper fall clearance exists in order to prevent striking ground or other objects in the event of a 

fall.   

Note: 

a connector is considered to have a compatible connection when the connectors have been designed 

to work together and that their shape/size do not cause gates to inadvertently open.    All connections must 

fully close and lock.   

 

4. MEANING OF MARKING AND / OR SYMBOLS:   

Manufacturer name or abbreviation name: 

 

YOKE or Y

 

YOKE Item number:   

e.g. N-623

 

Year code of manufacturing year : 2 digits,    e.g. 

14

 

Batch number: 3 Capital letters,    e.g. 

NBB

 

 

Make sure markings on products are legible.    The marking of item number and batch number can be 
cross-referenced to the Test Certificate issued by YOKE.   

 
 
 

5. MAINTENANCE

 

 

Remove cable grab from cable 

 

Clean cable grab with water and mild soap 

 

Wipe off with clean dry cloth, low-pressure compressed air may be used 

 

Store the cable grab in a cool, dry and clean environment - out of direct sunlight.    Do not store in 
areas where chemical vapors are present.    If stored for an extended period, refer to FORMAL 
inspection section. 

Lubricate with light oil such as WD-40. Use a small amount of oil on pivot area. Wipe off excess oil from body 
and surfaces of the cams so that oil is not transferred to the cable 

 

A FORMAL inspection of this unit must be performed at least annually by a competent person (other 
than the user).    The frequency of this type of inspection should be based on the conditions of use.   
Ensure that inspection results are recorded in the log section. 

 