YMGI WMMS-09EU-V2B Скачать руководство пользователя страница 8

INST

ALLER'S 

INSTRUCTION

INST

ALLER'S 

INSTRUCTION

P13 OF 36

P14 OF 36

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

Wrapping tape

Side Panel

Refrigerant pipes
and wires

Lineset cover

PART NAMES AND THEIR FUNCTIONS

LED lights

1) POWER:
    On/Off system running/stop. Flashs when 
    system falls in protection state.

2) COOL:
    On/Off the operation of cool ON/OFF.

3) HEAT:
    On/Off the operation of heat ON/OFF.

Remote Control

INSTALLATION INSTRUCTION

RECOMMENDED TOOLS FOR INSTALLATION

1) Mounting Indoor & Outdoor 
    Units and Running 
    Piping/Wiring

Ruler (Not Shown)
Stud-Finder
Dry-Wall Saw
Electric Drill
3" Hole Saw
Drill Extension
Hammer Drill and Bit (Not Shown)
Measuring Tape
Level
Flash Light
Screw Driver (Phillps and Flat)
Hammer
Knife
Scissors
Goggled Glass
Mask
Gloves
Ladder

2) Refrigeration Related Work

3) Electrical Related Installation

Flat Surface Wrentch (Two)
Flare-Nut Tool Set (Not Shown)
Hex Head Key Set
Torch for AC Application (Not Shown)
Heat Absorbtion Flux
Nitrogen (Not Shown)
Soap Bubble (Not Shown)
Vacuum Pump
Helium Leakage Check (Not Shown)
Manifold

Wire Cutter
Wire Stripper
Sharp Plier
Cable Ties
Black Tape for Electrical Use
lectrical Meter

Clamp Meter (Not Shown)
Manifold
Infra Thermometer (Not Shown)

4) Trial Running Units and 
Inspection

INLTS                          

STRT                             

COUP                      

COUP-H                    

OFST

  ELBF9                    

ELBF4                               

SOFT                      

TEE ENDF              

RDER

Not to damage line sets.

LINESET COVERS

Содержание WMMS-09EU-V2B

Страница 1: ...ight of YMGI Group This product is designed and manufactured free from defects in material and workmanship for the normal use and maintenance Installation operation maintenance and service shall follo...

Страница 2: ...service technician have any questions they can contact YMGI technical support division directly at Dear Customer s end User s unit Purchaser s installer s Contractor s Thanks for choosing YMGI product...

Страница 3: ...e humidity ranges installation operation maintenance service warranty parts and so on 4 Properly select correct most suitable YMGI product models of units and accessories for your HVAC applications jo...

Страница 4: ...he installation 5 Supply electrical power V Ph Hz measured at wiring terminal block of Indoor unit outdoor unit 7 Wire gauge length and terminal colors between circuit breaker disconnect switch to out...

Страница 5: ...horized contractor in YMGI list that is close to you otherwise 4 Authorized Distributor in YMGI Distributor list otherwise 5 Contractor Distributor you prefer who is close to you CONTACT FOR GENERAL T...

Страница 6: ...670 550 10 55 1 5 Centrifugal 2 4 9 x 5 3 MP35CB 2 2 NA Blue or the Like Yes 1 4 3 8 0 67 NA Yes Standard Washable 21 8 x 8 68 2 Yes Yes Yes Yes 32 9 x 27 4 x 9 38 36 8 x 31 7 x 11 7 59 5 78 2 112 23...

Страница 7: ...P3 are connected to the unit at the same time the default device will be AP2 WIRING DIAGRAMS WMMS 09EU V2B 59 2 WMMS 12EU V2B 59 2 WMMS 18EU V2B 59 2 WMMS 24EU V2B 59 2 BRIEF UNIT INFO UNIT DIMENSIONS...

Страница 8: ...iping Wiring Ruler Not Shown Stud Finder Dry Wall Saw Electric Drill 3 Hole Saw Drill Extension Hammer Drill and Bit Not Shown Measuring Tape Level Flash Light Screw Driver Phillps and Flat Hammer Kni...

Страница 9: ...ck It will not be easy to fix the leaking after the indoor unit is hung and connected Better to find and fix the leaking points before hanging and connecting it Connect the inter connecting pipes to t...

Страница 10: ...c ACCESSORIES CHECK FOR ALL ACCESSORY PARTS PRIOR TO THE INSTALLATION Name Picture Outdoor drain elbow Outdoor drain stem Paper pattern for installaition Remote controller Battery No 1 1 2 1 3 1 4 1 5...

Страница 11: ...remote default is Fahrenheit If you would like to switch between the remote displaying Fahrenheit and Celsius the MODE and the button simultaneously while the unit is turned off TIMER ON BUTTON This b...

Страница 12: ...r temperature will take place of remote local temperature as the unit s target temperature U TOUCH is what YOU WANT U TOUCH feature brings to you a true comfort level wherever and whenever you want RE...

Страница 13: ...d Comfort Products for A Sustainable and Efficient Green World YMGI Engineered Comfort Products for A Sustainable and Efficient Green World PRECAUTIONS Do not locate a heater or any other heat source...

Страница 14: ...n Defrosting Heating oil return Compressor overload protection unit stop System Unit malfunction IPM modular protection unit stop PFC protection unit stop Compressor malfunction Water spill protection...

Страница 15: ...nk 4 times Blink 5 times Blink 11times Blink 5 times Display the malfunction of indoor ambient temperature sensor when using this temperature sensor Green light blink once Yes Yes Yes Yes Yes No No No...

Страница 16: ...t what you pay for 13 Sign a contract with them The contract should list all the detailed work they will conduct and the standards they will follow Some contractors are willing to include a 1 year ins...

Страница 17: ...exceptions Most have resulted in equipment failure due to lack of knowledge and experience A few of the problems result from DIY s lack of knowledge in the following areas Sizing and selecting correc...

Страница 18: ...ifferent from what are typical in traditional split type air conditioning and heat pump systems and similar systems made by other manufacturers These are not defects Take some time to learn the functi...

Страница 19: ...ever questions you have or problems you have seen as a unit history No Date USER NOTES AND INSTALLATION SERVICE MAINTENANCE NOTES Notes Asked for Your Technician for Help Did You Ask YMGI Tech for Hel...

Отзывы: