The cost of not having your unit professionally installed can be more expensive than the additional cost of hiring a 
certified contractor. Protect your investment and warranty eligibility by doing it right the first time. 
 
 

 

Safety Precautions 

  

 

1. 

Follow  these  instructions  to  complete  the  necessary  installation  process.  Carefully  read  this  manual  before 
installation and unit startup or servicing.   

2. 

Wire size of power cord should be properly sized to meet the required electrical loads. Should the power cord get 
damaged, the power cord should be replaced with a manufacturer approved cable.   

3. 

After connecting the power cord, attach the electric box cover and secure properly.   

4. 

Always meet the nitrogen charge requirements when welding pipes.   

5. 

Never short-circuit or cancel the pressure switch as this will result in damage to the unit.   

6. 

Connect the wired controller before energizing, otherwise the wired controller cannot be used.   

7. 

Before using the unit, verify the piping and wiring are correct. This will avoid water leakage, refrigerant leakage, 
electric shock, or fire etc.   

8. 

Do not insert fingers or objects into the air outlet or inlet grille.   

9. 

Open a door or window for ventilation for allowing fresh air to enter the room to avoid depleting the oxygen while 
gas/oil supplied heating equipment is used during the installation.   

10. 

Never start up or shut off the unit by means of directly plugging into or unplugging the power cord from the power 
outlet.   

11. 

Turn off the unit after it runs at least five minutes, otherwise it will influence the oil return of the compressor.   

12. 

Do not allow children to operate this unit.   

13. 

Do not operate this unit with wet hands.   

14. 

Turn off the unit or disconnect the power supply before cleaning the unit. This will avoid possible electric shock 
or personnel injury.   

15. 

Never spray or splash water towards the unit. This can cause a malfunction in the unit or can result in electric 
shock.   

16. 

Do not expose the unit to moist or corrosive environments.   

17. 

While operating in cooling mode, do not set the indoor units room temperature too low. keeping the temperature 
difference between indoor and outdoor unit within 41

℉ 

(5

℃)

.   

18. 

YMGI Group recommends that only properly trained and authorized personnel be allowed to repair or service the 
unit. Improper repairs or servicing can result in electric shock or fire hazards. Please contact YMGI Group if you 
need help locating a qualified repair or service technician.    

19. 

Before  installation,  check  the  power  supply  to  ensure  it  is  sufficient  to  meet  and  is  in  accordance  with  the 
requirements specified on the nameplate of the unit. Ensure the power overload is functioning correctly and make 
sure it is properly maintained.   

20. 

Installation  must  be  performed  only  by  an  authorized  installer  or  HVAC  professional  in  accordance  with  the 
requirements set by the NEC and CEC. Do not attempt to install the unit yourself. Improper handling may result 
in water leakage, electric shock, fire, and voiding of the warranty.    

21. 

Be sure to use only approved accessories and parts to prevent water leakage, electric shock and fire. 

22. 

Make  sure  the  unit  is  grounded  properly  prior  to  connecting  to  power  source,  to  avoid  electric  shock.  Do  not 
connect the ground wire to a gas pipe, water pipe, lightning rod or telephone line.   

23. 

Energize the unit for 8 hours before operation. Turn off or disconnect the power within 24 hours to prevent short-
cycling (to protect the compressor).   

24. 

If refrigerant leakage happens in a confined space during installation, ventilate immediately. Poisonous gases 
can occur if the refrigerant gas is exposed to fire.   

25. 

Volatile liquids, such as paint thinners or solvents if exposed to the unit

’s surface will cause damage to the surface 

finish. Only use a soft cloth along with a mild non-abrasive detergent to clean the outer casing of the unit.   

26. 

If the unit does not operate normally or if you notice any type of burning odor, power off the unit and turn off the 
main power supply, then immediately contact your YMGI authorized repair service center or HVAC professional.   

 

 

Содержание WMMS-09C-V2B(78)1

Страница 1: ...s provided by YMGI Failure to follow and adhere to all codes and documentation can cause damage to equipment property even personal injury Installer Currently licensed certified HVAC technicians only...

Страница 2: ...ion to Mini Split Wall Mount Systems 14 Unit Diagram 15 Specification Sheet 16 Installation Diagram and Unit Clearance 18 Installation Location Selections 19 Recommended Tools for Installation 20 Inst...

Страница 3: ...ndling reclaiming recovering and recycling of certain refrigerants the equipment and tools necessary to perform these service procedures In addition some states or municipalities may have additional r...

Страница 4: ...or HVAC professional as soon as possible and provide the following information Data on the unit model number serial number and owner s name A detailed description of the unit s problem before and aft...

Страница 5: ...manufacturer may not require certified and licensed personnel to install Reading and following YMGI Group recommendations and requirements contained in the following pages and other documents is the f...

Страница 6: ...before pulling the piping through any structures at time of installation 2 Not installing an oil P trap in the copper suction line where the indoor unit is located 18 feet or more below the outdoor un...

Страница 7: ...r identifying marks on each pair of copper lines and wiring cable sets to keep from cross piping or cross wiring in multiple zone installations or where pipes for different single zone systems are clo...

Страница 8: ...0 days as of original shipping date from YMGI Group whichever comes first This is a standard limited liability warranty and DOES NOT cover the following Any damage or repairs to properties or persons...

Страница 9: ...rged accordingly 3 YMGI will ground ship out the parts ASAP Expedited shipping is available at the customer s expense 4 Replacement parts that have an approved warranty registration are to be warrante...

Страница 10: ...YMGI Engineered Comfort Products for A Sustainable and Efficient Green World 10...

Страница 11: ...liar with Local contractors have a faster response time and it will be easier for you to determine if they are reputable 4 Use only a reputable licensed certified HVAC installation professional to pre...

Страница 12: ...unit or can result in electric shock 16 Do not expose the unit to moist or corrosive environments 17 While operating in cooling mode do not set the indoor units room temperature too low keeping the te...

Страница 13: ...isconnect the power supply and switch off all circuits prior to inspecting or servicing the unit Inspecting and servicing the unit while the power supply is connected and the circuits are switched on...

Страница 14: ...bracket kit is used some outdoor units can be stacked 2 or 3 units high upon unit size and applications Air is discharged horizontally quietly and smoothly These units are a perfect fit in locations...

Страница 15: ...YMGI Engineered Comfort Products for A Sustainable and Efficient Green World 15 SAMPLE ILLUSTRATION OF INSTALLED SYSTEM...

Страница 16: ...48 45 40 36 48 45 40 36 50 45 40 38 50 45 40 38 Outdoor Sound pressure dB A 53 53 55 58 60 60 Airflow Indoor Unit S H M L CFM 412 380 351 276 412 380 351 276 635 577 482 383 635 577 482 383 1107 845...

Страница 17: ...2 x 3 4 Tube pitch a x row pitch b in 53 64 x 23 32 53 64 x 23 32 53 64 x 23 32 53 64 x 23 32 53 64 x 23 32 53 64 x 23 32 Fin spacing in 1 16 1 16 1 16 1 16 1 16 1 16 Liquid Pipe Diameter in 1 4 1 4 1...

Страница 18: ...YMGI Engineered Comfort Products for A Sustainable and Efficient Green World 18 INSTALLATION DIAGRAM...

Страница 19: ...e gas could leak Keep required distance away from walls Keep outdoor unit away from exhaust vents or chimneys Avoid installing unit near street or roadside where there is a risk of mud or water damage...

Страница 20: ...Two at One Time Flare Nut Tool Set Not Shown Hex Head Allen Wrench Sets Metric and Imperial Brazing Rods and Brazing Torch Outfit for AC Application Not Shown Brazing Flux Nitrogen Cylinder for Posit...

Страница 21: ...ce Note The center of the mounting bracket may not be the center of the Indoor unit Attach the mounting plate to the wall with a minimum of five screws evenly spaced to properly support the weight of...

Страница 22: ...ies Models Bracket Width 629mm 24 8 in For 24000 Btu h Series Models Bracket Width 820mm 32 3 in Unit Model Size A Size B Size C mm in mm in mm in 9k 12k of 21 SEER Series 70 2 35 1 3 8 70 2 18k 24k o...

Страница 23: ...ing through the hole from the outside Decide whether to remove the unloading piece in accordance with the piping direction as shown below After connecting the piping install the drain hose then the po...

Страница 24: ...indoor unit When the piping is directed to the right the piping power cord and drain pipe should be insulated and fixed to the back of the unit with a piping fastener Piping Connection a Connect indoo...

Страница 25: ...he manufacturer for installation of wall brackets and rubber pads Verify the wall brackets or rubber pad can safely support eh Outdoor Unit s weight Verify that the wall hangers or rubber pad is level...

Страница 26: ...s to avoid kinks Apply a small amount of refrigerant oil to the flare connection of the refrigerant pipe Properly align piping and tighten the flare nut using a standard wrench and a torque wrench as...

Страница 27: ...id and gas copper lines with at least 3 8 inch thick insulation tubes Band tape and secure the refrigerant lines Support copper lines at a proper distance apart to keep the tubes from sagging CUTTING...

Страница 28: ...this case wrap a wet rag around the pipe to protect the valves or other components from being overheated When using flux rub the tube surface using steel wool to remove any oxidation then clean and d...

Страница 29: ...oor to Indoor Unit Min Wire Size Outdoor Indoor Units Fuse is Factory Installed 09K 1 4 Liq 3 8 Gas 15 50 30 15 N 1 2 3 G 18AWG At Indoor Control Board 12K 1 4 Liq 1 2 Gas 15 50 30 15 N 1 2 3 G 18AWG...

Страница 30: ...e fitted Always use a dedicated power circuit specifically for the air conditioner For wiring requirements refer to the circuit diagram found inside the unit access door Confirm cable gauge as specifi...

Страница 31: ...YMGI Engineered Comfort Products for A Sustainable and Efficient Green World 31 Wiring Diagrams 115V Systems 208 230V Systems Diagrams are for reference only Actual terminal may appear different...

Страница 32: ...re not to discharge the refrigerant into the air directly How to Vacuum Air Tubes 1 Unscrew and remove caps from 2 way and 3 way valves 2 Unscrew and remove cap from service valve 3 Connect vacuum pum...

Страница 33: ...en any exposed piping to outside walls where ever possible 5 Seal and weatherproof the hole in the wall where the interconnecting wires and refrigerant pipes pass through Indoor Unit 1 Do all Remote c...

Страница 34: ...mote control instead of the machine to keep your current location at the temperature you are comfortable at 10 CLOCK Used to set the current time 11 TIMER ON Used to set the timed start function 12 TI...

Страница 35: ...ner will not operate if curtains doors or other items block the signal from the remote controller to the Indoor Unit If the signal cannot be transmitted properly either move the item s blocking the si...

Страница 36: ...ng sequence Heating mode is NOT available for cooling only air conditioners Fan Mode Each time the FAN button is pressed the fan speed is changed it the following sequence In FAN ONLY mode AUTO is not...

Страница 37: ...are at the preferred angle The automatic swing will stop and hold the set position Horizontal Airflow Control Using the remote controller to set various angles or adjusting the louvers to direct air...

Страница 38: ...on Mode Target Temperature 73 F 23 C or below FAN 72 F 22 C 73 F 79 F 23 C 26 C or below DRY Room temperature decrease 2 F after operating for 3 minutes Over 79 F 26 C COOLING 79 F 26 C SMART button i...

Страница 39: ...he and button 2 seconds to increase or decrease the time setting by 10 minutes Press the and button and hold to increase or decrease the time setting by 1 hour When your desired time is displayed on t...

Страница 40: ...the Super icon will display on the remote controller LCD screen SUPER Mode can be set when the air conditioner is turned on and running In SUPER Mode you can set the temperature airflow direction and...

Страница 41: ...et forth for an uncontrolled environment This equipment should be installed and operated with minimum distance of 50 cm 8 in between the radiator and your body Radiation Exposure Statement This equipm...

Страница 42: ...Communication cable has failed Connection between the filter board and the outdoor control board is incorrect or loose Connection between the filter board and the terminal is incorrect or loose Indoo...

Страница 43: ...of the indoor unit or outdoor unit is blocked or abnormal IPM module protection X X IPM board failure Outdoor unit fan is broken Outdoor unit motor failure Outdoor unit fan is blocked Condenser requir...

Страница 44: ...r prohibition of frequency rising protection against overload of outdoor coiled pipe 10 x x Frequency decreasing or prohibition of frequency increasing for power saving when it is being used simultane...

Страница 45: ...talled properly 6 X AC voltage out of range protection Supplied voltage is higher or lower than normal Indoor unit supply voltage is higher or lower than normal 7 X Communication failure between Indoo...

Страница 46: ...oose Indoor coil temperature sensor failure Indoor control board failure Refrigerant system is abnormal 17 PFC protection PFC failure Outdoor drive board failure 18 DC compressor start failure Outdoor...

Страница 47: ...sor is loose Indoor coil temperature sensor failure Indoor control board failure 36 X Communication failure between Indoor unit and Outdoor unit Communication cable is loose Communication cable has fa...

Страница 48: ...ion Supplied voltage is higher or lower than normal Internal supplied voltage of the unit is higher or lower than normal 7 X Communication failure between Indoor unit and Outdoor unit Communication ca...

Страница 49: ...oard failure 18 X DC compressor start failure Outdoor drive board failure Compressor failure 19 X Compressor drive issue Outdoor drive board failure Compressor failure Outdoor control board failure 20...

Страница 50: ...or control board failure 38 X Indoor EEPROM failure EEPROM chip is loose Indoor control board failure 39 Indoor fan motor running abnormally Indoor fan motor is blocked Fan motor cord connection is lo...

Страница 51: ...8487 8 21 594 0 95527085 43 2 801 3 227439565 7 20 611 0 99179340 44 2 706 3 266717909 6 19 678 1 02913875 45 2 615 3 305249514 5 18 794 1 06721353 46 2 528 3 342947037 4 17 954 1 10609872 47 2 444 3...

Страница 52: ...19 6 778 2 14682606 70 1 177 4 062450215 20 6 516 2 19524793 71 1 142 4 085229093 21 6 267 2 24333597 72 1 109 4 106941536 22 6 028 2 29151689 73 1 076 4 12888601 23 5 8 2 33944954 74 1 045 4 14971521...

Страница 53: ...SC1 Made of steel Coated with weatherproof polyester powder Model Size Inch Capacity A B LBs Btu h BRKT 0918 SC1 17 7 15 4 320 09K 18K BRKT 1860 SC 21 7 18 3 360 18K 60K BRKT XXXX ST1 Made of stainle...

Страница 54: ...asive cleanser CLEAN THE FRONT PANEL MAKE SURE TO TAKE IT OFF BEFORE CLEANING Take off the front panel Along the direction of arrows lift the front panel up meanwhile hold both slots of the front pane...

Страница 55: ...rd at a slight angle and pull downward carefully Cleaning To clean the dust adhering to the filters you can either use a vacuum cleaner or wash them with warm water and a neutral detergent the water s...

Страница 56: ...ower V Ph Hz 2 If the unit is still securely fastened 3 If the batteries of remote control are good 4 If the filter is loaded and clean 5 If the intake and discharge vents are clear from any obstructi...

Страница 57: ...nd Efficient Green World 57 USER NOTES AND INSTALLATION SERVICE MAINTENANCE NOTES INSTALLATION NOTES Put down any questions you have or problems you have seen as a unit history No Date Noes Asked Your...

Страница 58: ...and Efficient Green World 58 USER NOTES Put down any questions you have or problems you have seen as a unit history No Date Service Company Name Technician Name Phone HCAC License Job Not Performed b...

Страница 59: ...I Engineered Comfort Products for A Sustainable and Efficient Green World 59 SERVICE MAINTENANCE NOTES No Date Contents of Service Maintenance Technician s Company Name Technician Name Phone HCAC Lice...

Страница 60: ...u h 58 2 Single Zone 16 22 SEER 09 36K Btu h 58 4 78 1 Single Zone 18 23 SEER 09 36K Btu h Symphony CHOIR DC Inverter 59 2 DC Inverter Multiple Zone 16 SEER 2x09K to 5x12K Btu h 59 2S DC Inverter Mult...

Отзывы: