ELEVATING OUTDOOR UNIT
Strongly suggest to install the outdoor unit
above the ground either on a raised
platform or brackets as shown below.
Heat pump units must
be elevated above
ground level due to condensate that must
be drained out of the drain pan of the
condensing unit. If the condensate cannot
drain properly, it
may
accumulate and
result in an ice buildup that can cause
damage to the condensing unit.
We suggest using YMGI mounting
brackets and condensate drainage fitting
accessories
Electrical Installation
Requirement and Notice on Electrical Installation
1. The electrical installation for the air conditioner should observe the following requirements:
2. The electrical installation must be conducted by professionals in compliance with local laws and regulations and
the instructions in this manual. Never extend the power cord. The electric circuit must be equipped with a circuit
breaker and air switch both with sufficient capacity.
3.
The unit’s operating power must be within the nominal range stated in the instruction manual. Use a specialized
power circuit for the air conditioner. Do not draw power from another power circuit.
4. The air conditioner circuit should be at least 1.5m away from any inflammable surface.
5. The external power cord, the temperature controller wire and outdoor unit must be effectively fixed.
6.
The external power cord, the temperature controller wire and outdoor unit can’t directly contact any hot objects.
For example: they must not contact chimney pipes, warm gas pipes or other hot objects.
7. The external power cord, and the temperature controller wire and outdoor unit must not be squeezed. Never pull,
stretch or bend the wires.
8. The external power cord, the temperature controller wire and outdoor unit must not collide with any metal beam
or edge on the ceiling, or touch any metal burrs or sharp metal edge around.
9. Connect wires correspondingly by referring to the circuit diagram labeled on the unit or electric box. Screws must
be tightened up. Slipped screws must be replaced by specialized flat-head screws.
10. Please use the power cables that are delivered along with the air conditioner. Do not change the power cables
arbitrarily. Do not change the length and terminals of the power cables. If you want to change the power cables,
please contact YMGI
’s local service center.
11. Wiring terminals should be connected firmly to the terminal board. Loose connection is forbidden.
12. After the electrical installation is finished, please use wire clamps to secure the power cord, the temperature controller wire
and outdoor unit. Make sure the wires are not clamped too tight.
13. The wire gauge of power cord should be large enough. Damaged power cord or other wires must be replaced by specialized
wires. Wiring work must be done according to national wiring rules and regulations.
14. This outdoor unit has a heating four-way valve.