background image

ASSEMBLY INSTRUCTIONS

6

G

IV. Changing the Administrative Password:

 1."OPEN" mode changing: First open the door with the administrative password. 
     When the screen displays "OPEN", press the "*" key, and the system will enter 
     the administrative password changing status, displaying "------". You can enter 
     a new 1~8 digit administrative password, then press the "#" key to confirm 
    (system automatically confirms after entering 8 digits). The screen will display 
    "in", indicating that the password has been successfully changed.
2."Change Key" mode changing: Press the "#" key to start, and the LCD screen 
     will display "-----". After pressing the "0" key twice, the screen will display the 
     digits "00". Press the  setup key, and the LCD screen will re-display "------". 
     You can enter a new 1~8 digit administrative password, then press the "#" key 
     to confirm (system automatically confirms after entering 8 digits). The screen 
     will display "in", indicating that the password has been successfully changed.
3.Clear function: During the new password input process, pressing the "*" key 
     once will clear the last entered digit.
4.If no key is pressed within 8 seconds during modification, the modification 
    status will exit (the password will remain the old password) and return to 
    standby mode.

V. Query door access records:

1. To open the door, enter the password firstly. When the electromagnetic lock 
     engages for 5 seconds and the screen displays 'OPEN,' press either the '0' or 
     '8' key to query the previous door access records. Each record is displayed 
     across two screens.
2. Enter the desired date and time by directly pressing the numeric keys in the 
     format 'year-month-day hour:minute' (total of 11 digits). The corresponding 
    

Содержание IMISSB-0005

Страница 1: ...ASSEMBLY INSTRUCTIONS SAFE BOX HNXD V1 IMISSB 0005 IMISSB 0006 IMISSB 0007...

Страница 2: ...Item no Reference Image Qty X1 X6 X1 1 Con rm all parts are present prior to assembly 2 Do not lock the emergency key or emergency battery box into the cabinet A X2 Emergency key Emergency battery box...

Страница 3: ...the adjustable shelf 1 Position the cabinet near the wall and mark the locations of the anchor holes using a marker 2 Use a hammer drill to create holes at the marked positions 3 Move the cabinet to...

Страница 4: ...eset button First Time Safe Setup 1 Unfasten the right side panel and use the emergency key to open the safe The rst time to open the key cover is tight press the right edge position need to use a lit...

Страница 5: ...1 to 8 digit personal password and then press the key to con rm it The system will automatically con rm after entering an 8 digit password 2 If the password is correct OPEN will be displayed the elec...

Страница 6: ...con rms after entering 8 digits The screen will display in which tells you that the password has been successfully changed 3 Then the screen will display the new password for 1 second before returning...

Страница 7: ...nter a new 1 8 digit administrative password then press the key to con rm system automatically con rms after entering 8 digits The screen will display in indicating that the password has been successf...

Страница 8: ...the value 4 The system will validate the input numbers for their validity Invalid values that fall outside the speci ed range will not be con rmed The valid ranges for each parameter are as follows Ye...

Страница 9: ...screen will show LO BATTE low battery to indicate low voltage and remind you to replace the batteries 2 Operating voltage 4 2 7 5V 3 Operating current 320mA 4 Static current 35 A at 6 0V 5 Operating t...

Страница 10: ...Pure Easy...

Отзывы: