Yingli Solar PV Modules, Installation and User Manual / page 7
This supplement refers to modules of the following types:
FAMILY
YGE 245 SERIES
YGE-Z SERIES
YGE 295 SERIES
PANDA SERIES
TYPE
YL225P-29b
YL225P-29b
YL270P-35b
YL250C-30b
YL230P-29b
YL230P-29b
YL275P-35b
YL255C-30b
YL235P-29b
YL235P-29b
YL280P-35b
YL260C-30b
YL240P-29b
YL240P-29b
YL285P-35b
YL265C-30b
YL245P-29b
YL245P-29b
YL290P-35b
YL270C-30b
YL295P-35b
M O U N T I N G R E Q U I R E M E N T S
Mounting Method Option A: Bolts or clamps
Modules that Require
Four (4) Connection Points
The Following Modules Require Six (6)
Connection Points for Installations that
Exceed 50 psf (2400 Pa) Loading
YGE 245 SERIES
YGE 295 SERIES
YGE-Z SERIES
YGE 295 SERIES*
PANDA SERIES
* Connections are required at the four outer mounting holes
E L E C T R I C A L C H A R A C T E R I S T I C S
Nameplate ratings are average values. The electrical characteristics are /- 10 percent of the indicated values of Isc, Voc, and Pmax under Standard
Test Conditions (irradiance of 1000 W/m
2
, AM 1.5 spectrum, and a cell temperature of 25ºC). Refer to module datasheets for specific power output
tolerance.
Module
family
Module
type
Power
output
Voltage at
Pmax
Current at
Pmax
Open-circuit
voltage
Short-circuit
current
Max. DC system
voltage
Max. series fuse
rating
P
max
V
mpp
I
mpp
V
oc
I
sc
[W]
[V]
[A]
[V]
[A]
[V]
[A]
YGE 295
SERIES
YL295P-35b
295
36.3
8.12
45.4
8.63
600
15
YL290P-35b
290
35.8
8.10
45.3
8.62
600
15
YL285P-35b
285
35.5
8.02
45.0
8.50
600
15
YL280P-35b
280
35.5
7.89
45.0
8.35
600
15
YL275P-35b
275
35.5
7.75
45.0
8.30
600
15
YL270P-35b
270
35.3
7.65
44.8
8.20
600
15
YGE 245
SERIES
&
YGE-Z
SERIES
YL245P-29b
245
30.2
8.11
37.8
8.63
600
15
YL240P-29b
240
29.5
8.14
37.5
8.65
600
15
YL235P-29b
235
29.5
7.97
37.0
8.54
600
15
YL230P-29b
230
29.5
7.80
37.0
8.40
600
15
YL225P-29b
225
29.5
7.63
36.5
8.28
600
15
PANDA
SERIES
YL270C-30b
270
31.1
8.68
39.0
9.06
600
15 or 20
YL265C-30b
265
31.0
8.55
39.0
8.93
600
15 or 20
YL260C-30b
260
30.8
8.46
38.6
8.91
600
15 or 20
YL255C-30b
255
30.6
8.33
38.3
8.85
600
15 or 20
YL250C-30b
250
30.5
8.20
38.1
8.71
600
15 or 20
Module Supplement
Revision Date March 1, 2012 | Applicable for products in the United States and Canada.
YINGLI SOLAR
Mounting Method Option B: PanelClaw™ Attachment System
PanelClaw™ Approved Modules
YGE 245 SERIES
PANDA SERIES
Installation Method: Zep Solar Mounting Systems
ZSI, ZSII, ZSIII
YGE-Z SERIES*
* Refer to “YGE-Z Series Installation Supplement” for additional information