7. Usage and Maintenance
Recommendations

All repairs and interventions for refrigerant gas filling or discharging should be done in
Auto air conditioner authorized garages and by experienced personnel.

1500  km  after  the  installation  of  the  air  conditioner,  make  a  general  inspection,
especially check whether the compressor and the fasteners on it are tightened.

Twice a year, check the tension of the compressor follower belt; If it is old, replace it
with a new one.

Perform routine maintenance of the system to improve the operation of the air conditioner.

Keep the windows and doors of the vehicle closed while the air conditioner is operating.

Before  opening  the  cover  of  the  air  conditioner  for  maintenance  and  cleaning
operations, disconnect the vehicle's battery.

Protect  electrical  components  while  cleaning  the  system.  At  the  beginning  of  each
season, inspect all components of the system, including electrical components. 

Avoid using the air conditioner for a long time, run the unit for half an hour at least
once  a  month,  even  during  winter.  This  lubricates  some  components  and  prevents
them from drying out during extended periods of inactivity.

Check the condenser coil regularly and, if necessary, clean it using compressed air
without damaging the aluminum fins..

When  working  close  to  heat  exchangers,  be  careful  not  to  injure  yourself  with  the
pointed ends of the fins.

Inspect  the  operation  of  the  condenser  electric  fans.  When  the  air  conditioner  is
started, one of its engines starts. The second fan is activated when the temperature
rises, thanks to the control switch.

Do not forget that cleaning the condenser and inspecting the correct blowing are very
important operations. Insects, feathers or other foreign objects can accumulate on the
fins, reducing the effectiveness of the heat exchanger. A very dirty and unventilated
condenser reduces the performance of the air conditioning system and shortens the
life of the compressor, causing the compressor or its electromagnetic connection to
fail. If the air conditioner is used in a very dusty environment, perform more frequent
maintenance.

It uses R134a refrigerant in the air conditioning system.

We  recommend  replacing  the  dryer  in  case  any  major  repairs  are  required.  This  is
absolutely  essential  if  the  system  is  left  on  for  a  long  time  or  if  there  is  internal
moisture.

It is necessary to regularly clean the dust filters in the exterior air intake chamber and
the air intake chamber in the driver's compartment.

EN

Содержание YK 120 S Additional

Страница 1: ...YK 120 S Additional YILKAR Installation Instruction EN SSH MT 01 08 EN The right to make changes is reserved Printed in Turkey Y lkar Airconditioned 2023...

Страница 2: ...2 2023 H K bra ahin lk yay n First Publication REVISION NO PUBLISH DATE REVISING PERSON REASON FOR REVISION SSH MT 01 08 EN The right to make changes is reserved Printed in Turkey Y lkar Airconditione...

Страница 3: ...it Unit 1 Warranty and Liability 1 1 2 Security and Legal Regulations 2 Definition and Technical Information 3 Overview 3 2 General Description 4 1 General Assembly Diagram 4 4 Hoses and Fitting 4 4 1...

Страница 4: ...ning the Air Conditioner 6 Spare Parts 7 Usage and Maintenance Recommendations 6 1 Evaporator Spare Parts 6 2 Other Spare Parts SSH MT 01 08 EN The right to make changes is reserved Printed in Turkey...

Страница 5: ...ned and includes information on safe use of the device Please read this installation instruction carefully in order to fully install Y lkar air conditioner It is recommended to be stored in a safe and...

Страница 6: ...irst from the date of installation of the product In case the product fails during the warranty period the time spent in repair is added to the warranty period This period starts with the delivery of...

Страница 7: ...ame is true for the resistor on the fan if it will run on the unit and it has not cooled down completely Replace faulty parts immediately and have any detected faults corrected It is mandatory to use...

Страница 8: ...YK 120 S Additional 2 2 How does it work Vehicle roof air conditioners are heat machines that provide passenger thermal comfort by taking the heat inside the vehicle Vehicle roof air conditioners wor...

Страница 9: ...for 3 Blower Motors Dimensions Length x Width x Height 1300 x 420 x 226 mm Weight Without Mounting Kit 23 kg Maximum Total Electricity Intake 54 A 12 VDC 27 A 24 VDC 2 3 YK 120 S Additional Technical...

Страница 10: ...K 120 S 2007 1 PCS 501 21 YK120 01 12V 501 21 YK120 21 24V 2 U DOUBLE RAIL EAR 70 CM COMPLETE 1 SET 502 51 UC005 01 3 AIR SUCTION GRILL COMPLETE 4 BLACK 1 PCS 501 24 HEIPL 11 4 HOSE STEEL WIRE SPIRAL...

Страница 11: ...the help of current and voltage values in the air conditioning system In this way it ensures the regular operation of the air conditioner There are 12V and 24V options for the air conditioning system...

Страница 12: ...other by hoses in the air conditioner system 8 SLAVE MASTER 5 16 5 8 UNIVERSAL 315 01 MNL04 10 MERCEDES 315 01 MNL04 11 VW CRAFTER 315 01 MNL04 12 UNIVERSAL 315 01 MNL01 08 High Pressure Line Low Pre...

Страница 13: ...9 Assembly Step 1 First of all cut the U connection profiles to the dimensions suitable for the roof of your vehicle Assembly Step 2 Assemble the U profiles by interlocking the rail ear parts Assembly...

Страница 14: ...tep 4 The position of the U connection profiles to be used for the evaporator should be marked on the roof in the vehicle as shown below and mounted to the roof with a drill tipped trapezoidal M5x25 s...

Страница 15: ...tional Unit Installation Assembly Step 5 Assemble the evaporator unit to the U profiles previously mounted on the vehicle with drill tipped trapezoidal hexagon head M5x25 screws 1300 420 226 Air Flow...

Страница 16: ...ADDITIONAL UNIT VIEW 12 DRIVE DIRECTION EN...

Страница 17: ...trogen gas in it 12 WATER HOSE 5 16 HOSE AND FITTING CONNECTION 5 8 HOSE AND FITTING CONNECTION 12 WATER HOSE Stage 4 4 Hoses and Fitting For the water discharge hose connection the clamps must be tig...

Страница 18: ...radius of these hoses and the unions used with these hoses are given in the table below Fitting sets used in Y lkar air conditioning system are shown in the table below 4 4 1 2 Fitting Sets Table 2 Ai...

Страница 19: ...5 4 4 1 3 Clamp and Plastic Adapters 1 First of all cut the hoses straight one 2 Lubricate the inner part of the hose where the union will pass 3 Put the unions on the hoses properly 2 3 4 Tighten the...

Страница 20: ...ors Keep away from the moving elements and hot parts of the vehicle make the assembly by isolating it from all sharp edges and corners where the line will pass Bend the hoses to the minimum bending ra...

Страница 21: ...e in accordance with the unit and then mount the unit by inserting these nails onto the surface The unit location should be ergonomically chosen as a flat surface in an area accessible to the driver M...

Страница 22: ...e side of the fuse Place the other M8 cable end on the terminal of the vehicle s battery Pass the M6 wire end of the 16 mm B wire to one side of the fuse Place the other M8 cable end to the pole of th...

Страница 23: ...WER MOTOR D RT YOLLU M R EM M R KONDANSER MOTOR KONDANSER MOTOR DI SICAKLIK SENS R SICAKLIK SENS R KOMPRES R ARJ D NAMOSU KOFRA 80A ARA ASES ARA ASES ARA ASES 14 13 12 10 11 20 9 15 D 5 4 7 8 6 3 3 3...

Страница 24: ...tch Common End Pink 0 75 mm 9 D ACC 1 NU Cable 0 50mm 10 Power Control 2 NU Cable 0 50mm 11 A C 3 NU Cable 0 50mm 12 FAN 1 4 NU Cable 0 50mm 13 FAN 2 5 NU Cable 0 50mm 14 FAN 3 6 NU Cable 0 50mm 15 Co...

Страница 25: ...th the help of temperature probes in the unit 3 6 2 1 5 4 7 Set temparature Heating on Flap Closed Outside temparature Cooling on Fan speed Inside temparature 7 6 5 2 3 4 1 Flap Open 18 32 SET 21 Incr...

Страница 26: ...the heating button When the heating sign appears on the screen your air conditioner operates in heating mode optional Press the fan stage button to start the ventilation mode If there is no snowflake...

Страница 27: ...ture Sensor Open Circuit Cause of Occurrence The cable may have been cut or the socket may have come off The sensor may be faulty or broken Device Response When an error occurs the system shuts down a...

Страница 28: ...The system is vacuumed by the vacuum pump connected by the compressor This process ensures that the air and moisture remaining in the system are discharged from the system with the vacuum pump before...

Страница 29: ...PCS 501 24 HEIPL 11 5 VALVE EXP SANHUA RFKH SERIES X1 PCS 104 04 4SN00 01 6 SENSOR LOW PRESSURE YL 0 5 1 5 BAR X1 PCS 105 07 MDYL2 02 7 ORIFIS SANHUA NO 5 X1 PCS 104 05 1SN01 50 8 INION 5 8X18 U OR x...

Страница 30: ...26 18 32 SET 21 DIGITAL AIR CONDITIONER CONTROL PANEL x1 PCS 105 01 KU010 01 TERMINAL BOX x1 PCS 503 92 KFSET 01 6 2 Other Spare Parts EN...

Страница 31: ...parts should always be used during repairs Parts not approved by YILKAR may adversely affect the safety and proper operation of the unit In such cases the unit is out of WARRANTY For a fast and accura...

Страница 32: ...f inactivity Check the condenser coil regularly and if necessary clean it using compressed air without damaging the aluminum fins When working close to heat exchangers be careful not to injure yoursel...

Страница 33: ......

Страница 34: ...Vehicle Heating Cooling and Ventilation Systems Phone 90 224 215 53 28 pbx Fax 90 224 215 99 24 Address K kbal kl Mah 580 Sok No 6 Osmangazi BURSA TURKEY www yilkarklima com...

Отзывы: