background image

                                                                                               

M240 V4 Series IP MODEM User Manual

 

 

 

Add:Floor  14,A06  building,  No.370,Chengyi  Street,Jimei  District,  Xiamen,China. 
Web: www.yifanwireless.com     H86 592 6101492     Fax:+86 592 5222813 
 

 

21

 / 

35

 

software can makes IP MODEM into sleep state in idle time. When there is application data to 

transmit, IP MODEM can be triggered online ready for data transmission. There are total five 

methods to make IP MODEM online. 

 

AUTO 

IP MODEM always keeps online 

 

 

SMSD 

Send a special short message to make IP MODEM online. 
Any phone number’s SMS can wake up IP Modem, if the trigger number is empty. Otherwise 

only the trigg

er phone number’s SMS can trigger the IP Modem. 

 

SMS Phone No. 

Trigger phone number. If it is empty, sms received from any phone 

no. can trigger the device 

SMS Password 

The content of SMS to trigger. If it is empty, any content of sms can 

trigger the device 

 

CTRL 

Make IP MODEM online through a phone call to IP MODEM. 

Any phone number call can wake up IP Modem, if the trigger number is empty. Otherwise only 

the trigger phone number call can trigger the IP Modem. 

Note

if the trigger phone was set, the sim card in IP Modem Must have “caller ID display” 

function. 

 

CALL Phone No. 

Trigger phone number 

 

DATA 

Send special serial data to make IP MODEM online 

Содержание M240 V4 Series

Страница 1: ...l is suitable for the following model Xiamen Yifan Communication Technology Co Ltd Add Floor 14th No 370 Chengyi Street Jimei District XiaMen China Zip Code 361000 Tel 86 592 6101492 Fax 86 592 5222813 http www yifanwireless com M240 V4 Series IP MODEM User Manual Version V1 0 0 Product Name M240 V4 Total page36 Modem Product Type M240 G V4 GPRS IP MODEM M240 L V4 CAT4 LTE IP MODEM M240 L1 V4 Cat1...

Страница 2: ...nual 35 Add Floor 14 A06 building No 370 Chengyi Street Jimei District Xiamen China Web www yifanwireless com Hotline 86 592 6101492 Fax 86 592 5222813 2 Files Revised Record Date Version Remark Author 2021 07 30 V1 0 0 Original ZDM ...

Страница 3: ...ut written permission all commercial use of the files from Yifan are forbidden such as copy distribute reproduce the files etc but non commercial purpose downloaded or printed by individual all files shall be not revised and the copyright and other proprietorship notice shall be reserved are welcome Trademark Notice Yifan and Yeacomm are all registered trademarks of Xiamen Yifan Communication Tech...

Страница 4: ...Add Floor 14 A06 building No 370 Chengyi Street Jimei District Xiamen China Web www yifanwireless com Hotline 86 592 6101492 Fax 86 592 5222813 4 Note There may be different components and interfaces in different model please in kind prevail ...

Страница 5: ...neral 10 2 2 Encasement List 10 2 3 Installation and Cable Connection 10 2 4 Power 12 2 5 Indicator Lights Introduction 13 Chapter 3 Configuration 14 3 1 Connection 14 3 2 Configuration Introduction 14 3 3 IP Modem s Parameters Configuration 15 3 3 1 Run the Configure Tools 15 3 3 2 Re Power IP Modem 16 3 3 3 Work Mode 16 3 4 Data Service Center Settings 23 3 5 Serial port 26 3 6 IO function 27 3 ...

Страница 6: ...system It supports RS232 and RS485 port that can conveniently and transparently connect one device to a cellular network allowing you to connect to your existing serial devices with only basic configuration It has low power consumption design provides 2 ADC 3 I O be compatible digital I O channel ADC input pulse counter and pulse wave output function It has been widely used on M2M fields such as i...

Страница 7: ...tional Standard and Convenience Adopt terminal block interface convenient for industrial application Support standard RS232 and RS485 RS422 optional port that can connect to serial devices directly TTL logic level RS232 interface can be customized Support intellectual mode enter communication state automatically when powered Provide management software for remote management Support several work mo...

Страница 8: ...MB SRAM 256KB ADC 12 bit Interface Item Content Serial 1 RS232 and 1 RS485 15KV ESD protection Data bits 5 6 7 8 Stop bits 1 1 5 2 Parity none even odd space mark Baud rate 1200 230400 bps Indicator Power ACT Online Antenna Cellular Standard SMA female interface 50 ohm Lighting protection optional SIM UIM Standard 3V 1 8V user card interface 15KV ESD protection Power Terminal block interface rever...

Страница 9: ...nt Standard DC 12V 0 5A Power Range DC 5 36V Power Consumption Communication power consumption differs from different modules Working Status Power Consumption Communication 20 80mA 12VDC Standby 15 30 mA 12VDC Sleep 1mA 12VDC Physical Characteristics Item Content Housing Iron providing IP30 protection Size 91x58 5x22 mm Antenna and Accessories are not included Weight 205g Others Item Content Opera...

Страница 10: ...y Warning Forbid to install the IP MODEM when powered 2 2 Encasement List Name Quantity Remark IP MODEM host 1 Cellular Antenna 1 Power adapter 1 RS232 data cable 1 Or RS485 cable Manual CD 1 Certification card 1 Maintenance card 1 2 3 Installation and Cable Connection Dimension unit mm Installation of SIM UIM card Firstly power off the IP MODEM and press the button of the SIM UIM card outlet with...

Страница 11: ... female SMA outlet of the IP MODEM tightly Warning The antenna must be screwed tightly or the signal quality of antenna will be influenced User Interface Signal Definition Pin NO Name Function Extensible Function 1 PWR Power input anode N A 2 GND Power Ground N A 3 GND System Ground N A 4 RX RS232 RX N A 5 TX RS232 TX N A 6 A RS485 anode N A 7 B RS485 cathode N A 8 IO1 GPIO Reserved compatible pul...

Страница 12: ... 5 RS485 Cable optional Cable Color Signal definition Red RS485 A Black RS485 B Power adapter and communication cable connection 2 4 Power The power range of the IP MODEM is DC 5 36V We recommend user to use the standard DC 12V 0 5A power adaptor Warning When we use other power we should make sure that the power can supply power above 6W Ripple is less than 300mV and ensure that the instantaneous ...

Страница 13: ...6101492 Fax 86 592 5222813 13 35 2 5 Indicator Lights Introduction The IP MODEM provides three indicator lights Power ACT Online Indicator Status Introduction Power off IP MODEM is powered off on IP MODEM is powered on ACT off No data communication Blink Data is communicating Online off IP MODEM hasn t logged on network on IP MODEM has logged on network ...

Страница 14: ...figure the IP MODEM Configuration software tool All the settings are configured through the shipped software tool It s necessary to have one PC to run this tool Extended AT command All the settings are configured through AT command so any device with serial port can configure it Before configuration with extended AT command you should make IP MODEM enter configure state The steps how to make IP MO...

Страница 15: ...he correct format 12A format error the number of characters is odd 12G format error non hexadecimal character 3 3 1 Run the Configure Tools The Serial area shows the current serial port settings To configure IP MODEM please choose the correct serial port which connects to IP MODEM and the baud rate is 115200 with no parity then open the serial port If the button text is Close it shows the serial p...

Страница 16: ...ll load current settings from IP MODEM and displays on the right configure columns It s now ready to configure Note To enter configure state for 4G device may need more time It is about 40 seconds 3 3 3 Work Mode 3 3 3 1 App protocol The IP Modem can be configured many communication protocols to adapt for different applications Note The tool will show the reference parameters according to the comm...

Страница 17: ...will transfer meaning to 0xfd and 0xfe To know detail transfer meaning method please refer IP MODEM Transfer Meaning Explanation In the PROT work mode If this item is set to Yes all the transmission is transparent DCTCP This protocol is used in electric power field with TCP protocol PhoneNo Phone number DCUDP This protocol is used in electric power field with UDP protocol PhoneNo Phone number TRNS...

Страница 18: ... Phone Number If send phone number to serial port or not Hex To Text If convert HEX data to ASCII data or not Send SMS Hex If send SMS with Hex format or not SMSSER IP MODEM work as a SMS DTU All the data paced with special format send to any phone number The SMS from phone number will send to serial port Show Phone Number If send phone number to serial port or not Hex To Text If convert HEX data ...

Страница 19: ... 8 characters Hex To Text If convert HEX data to ASCII data or not Send SMS Hex This item is only valid when the Work Mode is PROT If this item is set to No IP MODEM will transfer meaning to 0xfd and 0xfe To know detail transfer meaning method please refer IP MODEM Transfer Meaning Explanation In the PROT work mode If this item is set to Yes all the transmission is transparent MQTT IP MODEM will w...

Страница 20: ...e the IP Modem work as a client Login Heartbeat Enable custom login and heart packet Disable no login and heart packet The flowing items can be ignored Data Format Text the flowing items are Text format Hex the flowing items are Hex format Login Packet Login packet Login Reply Login packet respond Heartbeat Packet Heart packet Heartbeat Reply Heartbeat packet respond Custom protocol Server mode It...

Страница 21: ...S can wake up IP Modem if the trigger number is empty Otherwise only the trigger phone number s SMS can trigger the IP Modem SMS Phone No Trigger phone number If it is empty sms received from any phone no can trigger the device SMS Password The content of SMS to trigger If it is empty any content of sms can trigger the device CTRL Make IP MODEM online through a phone call to IP MODEM Any phone num...

Страница 22: ...s empty the IP Modem kept online If it is not empty only the data matching to the offline data can made the IP Modem offline Trigger Port Set the trigger data source from PORT1 or PORT2 Data Format Format of the trigger data Text or HEX I O Sleep and Wake up Made the IP Modem sleep or wake up via I O level If the I O was in high level or suspend the IP Modem was sleep Otherwise It would trigger th...

Страница 23: ...a Data Trigger Off Offline data Trigger Port Set the trigger data source from PORT1 or PORT2 Data Format Format of the trigger data Text or HEX 3 3 3 3 Debug Level Debug information is used to debug software when there is software problem Debug Level Close no debug information output Level 1 simple prompt information output Level 2 detail debug information output Debug Port Port 1 debug info send ...

Страница 24: ...he multi DSC can receive the same application data Reconnect Int s reconnect time interval in second Connect Retry Times reconnect times Back To Main Server This item is only valid when you set Data Center Number as 1 In this mode IP MODEM will switch to backup center when main center have problems If this item is set to 1 IP MODEM will check whether the main center work fine timely When it detect...

Страница 25: ...r lost connection IP MODEM will try to reconnect after the configured reconnect interval Reconnect Int s reconnect time interval in second Connect Retry Times reconnect times 3 4 3 ICMP Link Check ICMP link check send to server a icmp packet and wait reply to check the link status If the reply is lost it means that the link may be broken ICMP Check Enable or Disable Dest Address The destination ad...

Страница 26: ...ata center RS232 baud the baud rate of the PORT 1200 1200 bps 2400 2400 bps 4800 4800 bps 9600 9600 bps 14400 14400 bps 19200 19200 bps 38400 38400 bps 56000 56000 bps 57600 57600 bps 115200 115200 bps Property Databit Parity Stopbit 8N1 8 Databit No parity 1 Stopbit 8E1 8 Databit Even parity 1 Stopbit 8O1 8 Databit Odd parity 1 Stopbit Bind Center1 the data from the port send to center 1 Center2 ...

Страница 27: ...l input port Output work as digital output port Indication will output low level when IP Modem connect data center output high level when disconnect from data center Port support COM GPRS SMS Protocol Modbus you can query or control IO status through modbus tcp command Custom you can custom command to query IO status Report Type Query Time IO Trigger Command Random string Data Format Text or Hex H...

Страница 28: ...icity support 4 20MA current input Voltage support 0 5V can customize to support 10V 15V Report Type Query Time IO Trigger Top Limit Sensor measurement range upper limit Low Limit Sensor measurement range lower limit ADC2 Same as above 3 7 Dial 3 7 1 PPP Dial DialNo Network Dial number GPRS WCDMA LTE 99 1 99 98 1 CDMA EVDO 777 APN Network APN GPRS WCDMA LTE cmnet uninet CDMA EVDO empty Username pa...

Страница 29: ...MA CDMA GSM 3 7 2 PPP Redial Re dial Interval s The interval between ppp dial in second Dial Retry Times max times of ppp dial failure 3 7 3 DNS Parameters When the DSC Internet access uses domain name It s necessary to set DNS server resolving the DSC domain name When the Data Center Number is 1 Main and Backup Center DNS Server is used to resolve the Main center and Backup center correspondingly...

Страница 30: ...em value in milliseconds MTU TCP Max packet length 3 8 2 Action for data send fail When data send to server fail there are not response from server IP modem will take a failed action after setting delay Re send int The time interval if re send fail Re Times The max times of sending data failure Fail Action You can decide what action to take if sending data fail including Dia again reconnect reboot...

Страница 31: ...traffic flow and so on The Device Manage Center also query and configure the device parameters Device Manage Enable or Disable Dev ID For Manage Device ID for manage center 8 character Protocol TCP or UDP Service Address manage center server address Port manage center server port 3 9 2 Manage by SMS Configure the IP Modem by SMS SMS Configure Enable or Disable Configure Password The password for S...

Страница 32: ...d inserted or install ok Signal Inquery the signal strength of simcard network Time Setting Synchronize local time Log Read log information of IP Modem Factory Factory the IP Modem s parameters Ver Info Query the version of IP Modem Reset Reset modem to factory IMEI Inquery IMEI of IP Modem Factory Factory the IP Modem s parameters Ver Info Query the version of IP Modem Reset Reset modem to factor...

Страница 33: ...pplication Case 4 1 Modem connect to data center In this application the client can communicate with the server side by gprs network IP modem configuration Configure server IP and port Fill in the APN from your simcard provider Repower modem wait it connected to server Then you can send data to test the communication between modem with data sever here use Netassit software to simulate data server ...

Страница 34: ...e Step one Enable SMS Manage function in modem set SMS sender s phone number the password is the one set in the modem it can be digit or letter Step two Send SMS according to the following format The message starts with the symbol and ends with and is without AT Example AT command for the main center is AT IPAD 120 42 46 98 and the corresponding SMS configuration should be IPAD 120 42 46 98 Add re...

Страница 35: ...User Manual Add Floor 14 A06 building No 370 Chengyi Street Jimei District Xiamen China Web www yifanwireless com Hotline 86 592 6101492 Fax 86 592 5222813 35 35 If set succesfully you will receive a return SMS with Config OK ...

Отзывы: