Preparation 

Before installation, please read through all safety information provided in this document. If you have any 
questions about operation and safe use of the battery system, please contact technical support. 
 
Before Operation: 

 

Work must be carried out by qualified personnel who have completed the required training and are 
certified to undertake electrical work in their state. 

 

Remove all metal items, such as jewelry, watch, pen etc. from body. 

 

To ensure the safety of construction personnel and equipment, disconnect the battery pack from 
the operating equipment during wiring. 

 

Follow the connection port description and system connection diagram. Pay attention to the 
terminal polarity of the battery module. 

 

Ensure the tools insulation are in proper condition and to use them correctly. 

 

Do NOT plug or unplug the battery when it is in operation. Necessary work should be conducted 
after the power supply is disconnected. 

 

Before  its  formal operation, ensure whether the power terminals are properly connected and 
tightened. When it is necessary to take measurements, be careful to use the instruments and tools 
to avoid short circuit and other accidents. 

 

Do NOT disassemble the battery without the proper authorisation from manufacturer 

 

 

Compatibilities 

Do NOT connect different batches, different types, old and new batteries in one bank.  To connect  the 

batteries into a bank (in series and/or in parallel), the batteries should meet the following conditions: 

 

All batteries must be from the same brand and same model. 

 

Have the same battery capacity (Ah). 

 

Are of similar age, preferably manufactured from the same batch. 

 

 

 

 

 
 

 

 

 

Содержание SL Series

Страница 1: ...as to whether the information contained herein is adequate and sufficient for a user s particular use It is the further responsibility of each user to ensure that all applications of Neuton Power pro...

Страница 2: ...ation 4 Features 4 Installation Guide 5 Preparation 5 Compatibilities 5 Installation Tools 6 Charging Batteries before Use 6 NPL SL Battery Terminal 7 Storage Safety and Limitations 8 Disengaging the...

Страница 3: ...e battery system gives it added protection which is responsible for collecting and analyzing the voltage temperature and current of each cell It provides cell balancing and protection against over vol...

Страница 4: ...at 25 C 4000 4000 Total Weight 15 5Kg 28kg Internal Resistance Fully Charged at 25 C 10m 5m Thermal Management Convection cooling Operating Humidity 60 25 R H Operating Temperature Charging 0 C 50 C D...

Страница 5: ...the battery module Ensure the tools insulation are in proper condition and to use them correctly Do NOT plug or unplug the battery when it is in operation Necessary work should be conducted after the...

Страница 6: ...s in a matrix the following steps are necessary to reduce the voltage difference between batteries and thereby optimising its performance 1 Fully charge your batteries separately 2 Disconnect the batt...

Страница 7: ...erson 175A blue plugs as shown below Note Anderson cables not included with the purchase of the battery Only use the same plug model type together Blue Anderson 175A The Anderson plugs will only inser...

Страница 8: ...isassemble the battery pack when it is live For optimum performance you must charge at 14 6V If you do not you will not be able to reach the full usable capacity of the battery To ensure the best perf...

Страница 9: ...2V Over discharge recovery voltage 11 6V The above settings ensure that the controller triggers its protection before the BMS does thereby prolonging the service life of the battery If solar charging...