Safety Instruction

 

   

      

 

 
 

 

Please conserve this manual as operation guidance. If you sell this product to other user, 
please make sure that they also receive this user manual. 

 

 

Always make sure that you are connecting to the proper voltage and that the line 
voltage you are connecting to is not higher than that stated on the decal or rear panel of 
the fixture. 

 

 

If the fixture is intended to indoor use only. To prevent risk of fire or shock, do not 
expose fixture to rain or moisture. Make sure there are no flammable, explosive or 
corrosive materials surrounded in 10meters while operating. 

 

 

The unit must be installed in a location with adequate ventilation, at least 5m away from 
adjacent surfaces. Be sure that no ventilation slots are blocked. 

 

 

Some fixture may carry high heat, do not aim at objective more than 2minutes.

 

 

Safe rope should be used to install machine. Bearing of safe rope should be more than 
3times of the machine weight. Complimentary signal cable transmits signals to 20 unit 
fixtures at most. Signal amplifier is a must to connect more fixtures. And a terminal 
should be added at the end of last fixtures’ DMX sockets, 120 Ohm, 1/4W resistance 
need welding between Pin 2 and Pin3.

 

 

Always disconnect from the power source before servicing or replacing fuse/lamp and 
be sure to replace with same fuse/lamp size and type. Cut off power before moving, 
repairing and cleaning the machine.

 

 

To avoid electric shock, all fixtures must be connected to circuits with a suitable earth 
connection. 

 

 

Always secure fixture using a safety chain and carrying handles. 

 

 

Do not operate at ambient temperatures higher than 104

(40

). 

 

 

The power cable for this fixture is 0.5 m

㎡,

  please mind the safety requirements in 

actual using, if any wrong operation, our company takes no responsibility for any loss. 
Also, make sure the power cord is never crimped or damaged.

 

 

In case of failure or mis-function occurred, stop using immediately. Never try to repair 
the fixture by yourself. Repairs carried out by unskilled people can lead to damage or 
malfunction. Please contact the nearest authorized technical assistance center. Buy the 
same spare parts/components from manufacturer directly. 

 

 

Avoid direct eye exposure to the light source while it is on.

 

 

Do not power on and power off the fixture frequently

 

 

When use DMX controller, please make sure that there is no interference sources(e.g. 
intercom, high frequency radio waves and radiation source)

 

 

Caution! 

There are no user serviceable parts inside the unit. Do not open the housing or attempt any 

repairs yourself. In the unlikely event your unit may require service, please contact your local distribution 

For your safe, please read this user manual carefully before turn on 

the fixture. This machine should be operated by qualified engineer

Содержание YR-COB100W

Страница 1: ...100W White COB LED Model YR COB100W ...

Страница 2: ...npacking 1pc Fixture 1 4pc Signal Convertor Cable 1pc User Manual Thanks for choosing our product Carefully unpack the box and check the contents to ensure that all parts are present and in good conditions If anything damaged in transit notify the shipper immediately and keep the packing material for inspection Again please save the carton and all packing materials If a fixture must be returned to...

Страница 3: ...re to replace with same fuse lamp size and type Cut off power before moving repairing and cleaning the machine To avoid electric shock all fixtures must be connected to circuits with a suitable earth connection Always secure fixture using a safety chain and carrying handles Do not operate at ambient temperatures higher than 104 40 The power cable for this fixture is 0 5 m please mind the safety re...

Страница 4: ...onnection Installation This machine should be mounted through the screw holes of truss Safety rope is a must to fix fixture well Make sure truss and safety rope have strong load capacity to bear more than 3 times of machine weight This machine should be installed by qualified technician ...

Страница 5: ...ton Menu Switch menu function UP Scroll upwards DOWN Scroll downwards ENTER Confirm by pressing ENTER 3 DMX Signal Input 3 PIN XRL port for DMX512 signal input daisy chain 4 DMX signal output 3 PIN XRL Port for DMX512 signal output daisy chain 5 Power Input AC power cable port input ...

Страница 6: ...one machine as master press the menu to choose the function you want Press other machines address to be DMX state Use signal cable to connect machines one by one Then slave machines will run the same as master machine Use controller to control lot of machines if all machines are set the same menu data or different manual data after use signal cable to connect to controller all machines will be con...

Страница 7: ...ures one at a time until normal operation is regained unplug both connectors and connect them directly together Colors cannot be mixed Random color mixing is on Turn off random color mixing Fixture does not reset correctly Electronic or mechanical failure Contact service technician Lamp missing or blown Disconnect fixture and replace lamp No light lamp cuts out intermittently or burns out too quic...

Страница 8: ...ource would be 100 6 dr dr 0 Standard Dimmer Curve dr 1 Dimmer Curve1 dr 2 Dimmer Curve2 dr 3 Dimmer Curve3 dr 3 Dimmer Curve4 DMX protocol DMX512 Channel Chart 3CH CH Function Specification CH1 Dimmer 0 255 White Dimmer from dark to bright CH2 Flash 1 255 flash speed from slow to fast CH3 Macro function 000 020 Standard Dimmer Curve 021 040 Dimmer Curve1 041 060 Dimmer Curve2 061 080 Dimmer Curve...

Страница 9: ... AC110V 240V Frequency 50 60Hz Machine Power 100W LED source 100W White LED Pure white 6000 6500K Warm white 3000 3200K Cold white 7500 8000K LED QTY 1pcs Strobe 0 20 Hz Dimmer 4 kinds of dimmer methods Fan 1pcs temperature detect fan Noise Same as Ambient noise away 1 5m Beam Angle 60 can be changed by barn door Control Mode DMX512 Manual Channel 3 1CH switchable Net weight 1 5kg Size 26 26 11 5c...