background image

12

WARRANTY INFORMATION

Ritchie Engineering guarantees YELLOW 

JACKET

®

 products to be free of defective 

material and workmanship which could 

affect the life of the product when used 

for the purpose for which it was designed.  

This warranty does not cover items that 

have been altered, abused (including 

failure to use the correct type of vacuum 

pump oil) or returned solely in need of field 

service maintenance.

If found defective, we will either replace 

or repair at our option products within 

warranty period. Returns must be prepaid.
Warranty does not cover use of lithium 

bromide, ammonia or leak stop type 

products.
See www.yellowjacket.com to register 

your product or contact Customer Service 

for full warranty details.

How to Obtain Service

Most returned pumps are merely in need of 

normal field service maintenance, such as 

changing oil or making minor adjustments.  

In many instances, the troubleshooting 

information in this manual can save you 

the time and effort of returning your 

pump.  When the information contained in 

this manual, however, does not solve the 

problem, please call for service.

Contact the Ritchie Engineering Customer 

Service Department:

Phone:  (952) 943-1333 or
    

(800) 769-8370

Fax: 

(952) 943-1605 or

    

(800) 322-8684

E-mail: [email protected]

You will receive personal help to determine 

if the problem can be solved without 

sending your pump to the factory and 

taking it out of service.

Ritchie Engineering Company, Inc.
YELLOW JACKET

®

 Products Division

10950 Hampshire Avenue South
Bloomington, MN 55438-2623 USA
E-mail: [email protected]
Website: www.yellowjacket.com
Phone:  (800) 769-8370
    

(952) 943-1333 INT’L

Fax: 

(800) 322-8684

    

(952) 943-1605 INT’L

©

2020 Ritchie Engineering Company, Inc.                    Printed in the USA                                                   PN #143060_RevB

Warranty is void if the set vacuum pump voltage does not match the power supply.

Содержание SuperEvac PLUS II

Страница 1: ...SuperEvac PLUS II Vacuum Pump Operation and Maintenance Manual Models 9371x 9374x 9376x 9378x 9379x PN 143060_RevB...

Страница 2: ...arrange inspection of the pump and packaging The CARRIER ALONE is responsible for handling and settling your claim Ritchie Engineering will cooperate in assessing damage if the pump is returned to the...

Страница 3: ...motor can run on voltage as low as 85 volts with no issue and draws fewer amps than AC motors Large Impact Resistant Toughened Nylon Feet Reduces vibration and increases durability and longevity Help...

Страница 4: ...d stage similar to two single stage pumps connected together If air a non condensable remains in the system it collects on the high side reduc ing system efficiency This causes a rise in head pressure...

Страница 5: ...uum just prior to shut off 7 Disconnect pump and put cap on intake to keep out contaminants 8 If an extension cord is needed refer to the below chart for proper sizing 6 Use the 4 in 1 Vacuum Charge V...

Страница 6: ...3 Replace cover and screw down by hand Do not use drill as cover could crack CAUTION Always remove cord before changing voltage Incorrect voltage setting can result in destruction of controller elect...

Страница 7: ...mosphere and switch on pump run up to speed before connecting to system Four Most Common Comments on Pump Return Paperwork Your SuperEvac PLUS II pump features a heavy duty high torque motor for cold...

Страница 8: ...dropped Micron gauge malfunction Poor motor performance Dirty oil Air leaks System leaks Fitting sealant compound Call factory Verify with second gauge Repair or replace Flush 1 to 3 times Repair or...

Страница 9: ...coupling Replace motor Tighten bolts Adjust replace coupling Pump Cartridge Dirt low improper oil Air leaks 1 Caps connections 2 Gaskets O rings 3 Fittings 4 System leak Flush and replace oil Tighten...

Страница 10: ...92741 92741 3 Oil fill cap and seal 93390 93390 93390 93390 4 Oil fill fitting 93391 93391 93391 93391 5 Pair of sight glass screws 92933 92933 92933 92933 6 Sight glass bezel 92934 92934 92934 92934...

Страница 11: ...93366 93366 22 Complete parts for blank off 93367 93367 93367 93367 Motor 23 SuperEvac Universal Motor 93713 93713 93713 93713 24 Locking IEC to NEMA 5 15 92755 92755 92755 92755 25 Locking IEC to UK...

Страница 12: ...intenance such as changing oil or making minor adjustments In many instances the troubleshooting information in this manual can save you the time and effort of returning your pump When the information...

Отзывы: