Part #

 

Description

 

Part #

 

Description

 

95156

 

12A Breaker

 

95575

 

XLT Compressor ONLY

 

95210

 

Strain Relief

 

95215

 

Power Cord

 

95573

 

Momentary Rocker Switch

 

95451

 

Gauge High

 

95217

 

Rubber Feet

 

95452

 

Gauge Low

 

95444

 

Case Front

 

95453

 

Manifold Assembly

 

95445

 

Case Back

 

95515

 

Discharge Port

 

95446

 

Case Half

 

95522

 

Suction Port

 

95447

 

Cord Wrap

 

95563

 

Condenser Assembly

 

95449

 

Grommet

 

93394

 

Cap

 

95574 

 

LED Housing w/Mounting Nut

 

95576

 

PCBA for XLT Compressor

 

Part #

 

Description

 

95248

 

Umbilical Cord Overfill Sensor

 

95188

 

Shorting Cap for Umbilical Cord

 

Содержание RecoverXLT

Страница 1: ...efrigerant Recovery System PN 151204 RevB Operation and Maintenance Manual for 95760 and 95762 For serial numbers 22120038 and higher English Spanish French and German manuals available at https yello...

Страница 2: ...h provides at least four air changes per hour is present or place the unit 18 above the floor during use The RecoverXLT should not be used near open containers of gasoline or any other flammable liqui...

Страница 3: ...read an increase in suction pressure indicating the refrigerant that was trapped in the machine 2 Wait until the Low Pressure Switch again stops the unit at the appropriate vacuum 3 Close the valve o...

Страница 4: ...1 4 DISCHARGE port of the RecoverXLT Note Be sure to connect hose ends with shut off to suction and discharge ports of recovery machine for best performance use 3 8 hoses 6 Purge all hoses of non cond...

Страница 5: ...e pulled into a vacuum as required by EPA standards This process requires the following equipment 1 An extra hose for the push pull recovery 2 A recovery cylinder with about 5 lbs of refrigerant 3 A s...

Страница 6: ...ns there is already liquid in the tank and over filling can be a concern Over filling a recovery cylinder can have disastrous results 3 Refrigerant responds to heat Therefore a significant increase in...

Страница 7: ...Tighten hose connections Compressor seals are worn Rebuild compressor replace piston seal Hoses are not tight Tighten hoses Leak in HVAC R system Find and repair leak in system Unit running sluggish...

Страница 8: ...s 8 Compressor 1 25 HP 2 Cylinder Oil less Reciprocating Air Cooled Power Source 100 240VAC 1ph 50 60Hz Amperage 14 0 amps Motor Type Variable Speed Brushless DC 1200 3000 RPM Size Height 12 50 Width...

Страница 9: ...ocker Switch 95451 Gauge High 95217 Rubber Feet 95452 Gauge Low 95444 Case Front 95453 Manifold Assembly 95445 Case Back 95515 Discharge Port 95446 Case Half 95522 Suction Port 95447 Cord Wrap 95563 C...

Страница 10: ...ed or improperly maintained The following must be done before returning unit 1 Call our technical service personnel at 800 769 8370 to assess if the problem can be resolved over the phone 2 Obtain an...

Отзывы: