• Only use a certified charger/cord with an output of 5 V (dc) ±5%, 1 A ±5%
• Keep the device out of extremely high or low temperature locations
• Do not expose the battery to liquid
• Do not use the device if you notice any damage to the battery
• Do not disassemble or modify the battery
• Handle and dispose of the battery per local regulations
• If the recharging operation fails to complete, even when the specified recharging
time has elapsed, immediately stop further recharging
• Do not leave the battery unattended while charging
• Unplug the charger when the battery is fully charged
• Improper use or disposal of lithium ion batteries can cause a fire
• This instrument is not intended for use in flammable environments
CAUTIONS
AUTOMOTIVE CHEMICAL FALSE TRIGGERING
Brand or Chemical Name
Response
Clear in 20 Seconds
Windshield washer solvent
Y
Y
Ford spot and stain remover
Y
Y
Ford rust penetrant and inhibitor
Y
Y
Ford gasket and trim adhesive
Y
Y
Permatex natural blue cleaner & degreaser
Y
Y
Ford brake parts cleaner
Y
Y
Ford clear silicone rubber
Y
Y
Motorcraft G-05 antifreeze / coolant
N
N/A
Gunk liquid wrench
Y
Y
Ford pumice / lotion hand cleaner
N
N/A
Ford motorcraft DOT3 brake fluid
N
N/A
Ford spray carburetor tune-up cleaner
Y
Y
Ford silicone lubricant
N
N/A
Dexron ATF
N
N/A
Mineral engine oil (Valvoline 5W30)
N
N/A
4
Due to similarities between the composition of refrigerants and some common automotive
chemicals, the detector may alarm when in the presence these chemicals, which can make it
more difficult to pinpoint a refrigerant leak. Do not use cleaning agents or solvents on or near
refrigerant lines and wipe away dirt or potential false-triggering chemicals using a dry shop
towel or shop air. Make sure the chemicals listed are not in close proximity to the suspected leak
location to avoid false-triggers during leak detection.