![yellow jacket 69336 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/yellow-jacket/69336/69336_instruction-and-operation-manual_909885002.webp)
The Y
ELLOW
J
ACKET
®
A
CCU
P
ROBE
™
UV
and A
CCU
P
ROBE
™
II Hand-held Leak Detec-
tors detect all HCFC refrigerants such as R-22
and R-124. The ultra-sensitive long life sensor
with exclusive Heated Electrochemical Sensor
Technology (HES) also detects the more cur-
rent, difficult-to-detect HFC refrigerants such
as R-134a, R-404A, R-407C and R-410A (see
page 6 for a more complete chart of detectable
refrigerants).
The A
CCU
P
ROBE
UV is equipped with the
unique digital SmartAlarm
™
LED display –
the first digital leak size indicator in a
hand-held heated sensor leak detector. This
feature takes the guesswork out of whether or
not to repair a small leak. Unlike the more
traditional LED bar graphs that copy or mimic
the audio alarm signal, the SmartAlarm digital
leak size indicator measures, registers and
displays the leak size independently from both
the audio alarm and the sensitivity level.
The
ACCU
P
ROBE
UV also features a 3 LED
UV light system that works with 395-415nm
wavelength leak tracing dyes. The sleek, ergo-
nomic design of these YELLOW JACKET
leak detectors makes them easy to use in close
areas and extendable into hard-to-reach areas.
Introduction
Features
Advanced digital SmartAlarm™ leak size
indicator (
AccuProbe UV
)
Flashing visual alarm indicator at probe end
(
AccuProbe UV
)
Audio mute button (
AccuProbe UV
)
Operates on 4 AA alkaline batteries
(
AccuProbe UV
can also use AC power)
3 LED UV light system that works with
395-415nm wavelength leak tracing dyes
(
AccuProbe UV
)
Microcontroller technology
Ultra-high sensitivity to detect 0.06 oz
(1.7g)/yr. of R-134a and 0.03 oz (0.9g)/yr.
of R-22
Automatic calibration and reset to ambient
Detects HFC, HCFC and CFC refrigerants
(see page 6)
Long life stable sensor utilizing Heated
Electrochemical Sensor (HES) technology
3 selectable sensitivity level settings
Sleek ergonomic design
Low battery indicator
Temp Range 24° to 125°F (-4° to
+
52°C)
Humidity 0 to 95% RH noncondensing
SAE J2791Certified
CE Marked
True mechanical pump
Specifications
Sensitivity
0.06 oz (1.7g)/yr. of R-134a 0.03 oz (0.9g)/yr. of R-22
Power
4 AA alkaline batteries
Probe Length
17 inches (430mm)
Calibration
Automatic
Sensor Life
>300 hours
Length(body)
10.5 inches (270mm)
Weight
AccuProbe II - 15 ounces (430g); AccuProbe UV - 17 ounces (480g)
Battery Life
4.5 hours continuous
Response Time
Instantaneous
2