background image

 

 

 
 

AUTOMOTIVE REFRIGERANT ANALYZER 

 

OPERATION MANUAL 

Analyzer Part Number: 68941 

 
 

 

 

Содержание 68941

Страница 1: ...AUTOMOTIVE REFRIGERANT ANALYZER OPERATION MANUAL Analyzer Part Number 68941...

Страница 2: ......

Страница 3: ...6 Back Panel Connections 9 1 3 7 Hard Shell Storage Carrying Case 10 2 YELLOW JACKET 68941 OPERATION 11 2 1 FIRST USE 11 2 1 1 Battery Charging 11 2 2 TURNING ON THE UNIT 11 2 3 CALIBRATION 11 2 4 TE...

Страница 4: ...utions may result in fire explosion injury or death Sample Filter Warning Replace the sample filter of the instrument AS SOON AS RED SPOTS OR DISCOLORATION BEGIN TO APPEAR ON THE OUTSIDE DIAMETER OF T...

Страница 5: ...d heat sources and without sparking components Ensure adequate ventilation in the recycling machine design to prevent the accumulation of refrigerants DO NOT breathe refrigerant and lubricant vapor or...

Страница 6: ...loomington MN 55438 Tel 952 767 7208 EMAIL custserv yellowjacket com Visit us at www yellowjacket com 1 INTRODUCTION AND OVERVIEW 1 1 General Contamination of refrigerants either in storage cylinders...

Страница 7: ...e it can be removed by most refrigerant recycling equipment Since air is not considered to be a contaminant it is possible to read 100 R134a plus 5 air The instrument interfaces with the user with an...

Страница 8: ...strument and disassembly will void the warranty 1 3 2 R134a Sample Hose The 2 meter R134a Sample Hose is constructed of polyurethane ether with a plastic fitting on the analyzer end and a brass flow r...

Страница 9: ...t 1 3 3 R134a Tank Adapter Fitting The R134a Tank Adapter Fitting will provide the user with an adapter to allow connection of the R134a sample hose to a R134a cylinder ACME port 1 3 4 AC Power Adapte...

Страница 10: ...Red and Green LED s at the top of the Control Panel are used for visual Pass Fail indications 1 3 6 Back Panel Connections The connections located on the back panel are illustrated below CAUTION The...

Страница 11: ...se The hard shell storage carrying case is custom fit to the YELLOW JACKET 68941 It provides rugged protection for the instrument as well as convenient storage for all components The enclosure is gene...

Страница 12: ...ropriate sample hose to the identifier now 2 3 Calibration Each time the YELLOW JACKET 68941 begins a new test cycle it must first self calibrate The calibration takes 30 seconds and brings fresh air...

Страница 13: ...rigerant tested is 99 9 100 0 pure R134A the Green LED will illuminate Should the refrigerant be less than 99 9 pure the Red LED will illuminate In either case pressing the left button will turn the u...

Страница 14: ...intouts may be made following the same procedure Figure 9 and Figure 10 show sample printouts for various test results 68940 Refrigerant Analyzer TESTED R134A R134A 100 0 R12 0 0 R22 0 0 HC 0 0 UNK 0...

Страница 15: ...er When inspecting the sample filter look completely around the entire outside diameter of the white filter element located inside of the clear plastic housing Look for red spots or the beginnings of...

Страница 16: ...ery voltage falls below an acceptable level The instrument should then be connected to AC power using the included power supply to recharge the battery 3 5 Error Messages In the unlikely event that an...

Страница 17: ...per sample ACCURACY Better than 2 for detected compounds when the R134A value exceeds 90 R40 Detection begins between 2 3 POWER 12 VDC 2 Amps Maximum OPERATIONAL TEMPERATURE 50 122o F 10 50 o C UNKNO...