The Yellow Jacket

TM

 52070F Thermal Imager is an accurate, high-qual-

ity handheld thermal imaging camera.  The 52070F has a special mode 
specifically for elevated skin temperature screening called Temperature 
Screening Mode.  When the 52070F thermal imager is operated in the Tem-
perature Screening Mode, the thermal imager meets the recommendations 
established by the U.S Food & Drug Administration (FDA) for elevated skin 
temperature screening.  When operated in Temperature Screening Mode, the 
52070F has a measurement accuracy of ±0.9F (±0.5C) over a temperature 
screening range of 93.2-102.2°F (34-39°C).  The thermal imaging camera 
has been calibrated in the factory using a blackbody temperature reference 
source.   No on-site calibration is required.  

Meets international performance standards for thermographic devices. 
Not FDA-cleared or approved.

KEY FEATURES

• Temperature Screening Mode 
• 80x80 thermal resolution or 6400 temperature measurement points
• 50Hz frame rate.  The camera creates images at the rate of 50 per 
   second so moving subjects appear clearer
• Hot, Cold, Center temperature tracking
• Large, easy-to-read graphical TFT display
• Bluetooth

®

 image sharing to Th  iOS and Android app

• Scene temperature range Lock 
• Buzzer alarm.
• 8 hours operating time with rechargeable battery.
• Compact, rugged design

THE TH  MOBILE APPLICATION (“PROGRAM”) IS OFFERED 

BY SHENZHEN EVERBEST MACHINERY INDUSTRY CO., LTD.  NEITHER 

SOUTHWIRE COMPANY, LLC OR ANY OF ITS AFFILIATES SHALL BE 

RESPONSIBLE FOR OPERATION OR FUNCTIONALITY OF THE PROGRAM.  

YOU ASSUME THE ENTIRE RISK AS TO THE RESULTS AND PERFORMANCE OF 

THIS PROGRAM. ADDITIONALLY, SOUTHWIRE COMPANY DOES NOT WARRANT, 

GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING THE USE OF, OR 

THE RESULT OF THE USE OF, THE PROGRAM IN TERMS OF CORRECTNESS, 

ACCURACY, RELIABILITY, CURRENTNESS, OR OTHERWISE, AND YOU RELY ON 

THE PROGRAM AND RESULTS SOLELY AT YOUR OWN RISK. YOUR USE OF 

THE PROGRAM IS GOVERNED BY THE POLICIES, PROCEDURES AND PRIVACY 

PRACTICES OF SHENZHEN EVERBEST MACHINERY INDUSTRY CO., LTD. 

IMPORTANT INFORMATION CONCERNING ELEVATED  

SKIN TEMPERATURE SCREENING

 Temperature measurement should not be solely or primarily relied upon 

  to diagnose or exclude a diagnosis of COVID-19, or any other disease 

• Elevated body temperature in the context of use should be confirmed 
  with secondary evaluation methods (e.g., an FDA approved non-contact 
  infrared thermometer (NCIT) or a clinical grade contact thermometer)
• Public health officials, through their experience with the device in the 
  particular environment of use, should determine the significance of any 
  fever or elevated temperature based on the skin telethermographic 
  temperature measurement
• The thermal imaging camera should be used to measure only one 
  subject’s temperature at a time
• Visible thermal patterns are only intended for locating the points 
  from which to extract the thermal measurement.

RECOMMENDATIONS FOR USING THE THERMAL IMAGER 

FOR ELEVATED SKIN TEMPERATURE SCREENING

(Consistent with ISO/TR 13154: 2017 guidelines on thermograph usage)
Preparing the Area where you will use the thermal imaging system
• Recommended room temperature should be 64-86 °F (18-30 °C) 
  with a relative humidity of 60 percent.
• Try to control other conditions that could impact the temperature 
 measurement:
• Avoid reflective backgrounds (for example, glass, mirrors, metallic 
  surfaces) to minimize reflected infrared radiation.
• Set up the thermal imaging camera in a room with minimal movement 

Содержание 52070F

Страница 1: ...ellow JacketTM 52070F Thermal Imager Contents Made in China Fabriqu en Chine Product distributed by Produit distribu par Southwire Company LLC One Southwire Drive Carrollton GA 30119 2020 Southwire Co...

Страница 2: ...UTHWIRE COMPANY DOES NOT WARRANT GUARANTEE OR MAKE ANY REPRESENTATIONS REGARDING THE USE OF OR THE RESULT OF THE USE OF THE PROGRAM IN TERMS OF CORRECTNESS ACCURACY RELIABILITY CURRENTNESS OR OTHERWIS...

Страница 3: ...person s surface skin temperature at a time Position the person at a fixed distance of 3 feet 1 meter from the thermal imaging system directly facing the camera Recommended viewing angle is approxima...

Страница 4: ...Interface 13 Tripod mounting hole THE THERMAL IMAGER DISPLAY 1 Current Emissivity Setting 2 Battery Charge Level Indicator 3 Hot Temperature Point Reading 4 Cold Temperature Point Reading 5 Center Cr...

Страница 5: ...sy to use The 52070F has an IR resolution of 80 x 80 or 6400 temperature measurement points Here are the basic steps Covered in more detail later in this Guide 1 Press and hold the Power Button for gr...

Страница 6: ...than 2 seconds to turn the imager ON The start up screen will be shown until the shutter resets the image After the startup period the imager will display a real time IR thermal image along with an IR...

Страница 7: ...re the image 3 To discard the image short press the trigger again The display will return to a live image 4 Press SAVE to save the image to memory 5 If the image is stored successfully on the internal...

Страница 8: ...he Setup Menu buy pressing the Down Arrow button 3 Press the OK button to enter Setup menu There are three available options Bluetooth Brightness and Auto Off 4 Turn Bluetooth ON 5 Run the Thermview a...

Страница 9: ...E TEMPERATURE To help in identifying and diagnosing problems the 52070F thermal imager allows you to lock the temperature range of the current scene that you are viewing TO LOCK THE SCENE TEMPERATURE...

Страница 10: ...surement is as accurate as possible TEMPERATURE UNITS 1 Press OK Button to open the Settings Menu 2 Press OK Button to select this option The color of option value will change to black C 3 Use the RIG...

Страница 11: ...the brightness of the LCD display brightness Press the ESC OK button to exit The avail able brightness range is 10 to 100 in 10 steps Auto Power Off Press OK Button to select this option Use the UP or...

Страница 12: ...nload and run Thermview for iOS Please search in Apple store with keyword Thermview download and run DATE AND TIME Press OK Button to enter the Time Date menu The changes that you make to the date and...

Страница 13: ...pictures SCREEN CAPTURE While in Thermal imaging mode use HOLD Button to enter the HOLD mode as show below Press the OK Button to capture the image on the LCD display After the image has been saved to...

Страница 14: ...ect temperature 0 C MEASUREMENT ANALYSIS Spotmeter Center Spot Automatic Hot Cold Detection Auto hot or cold markers Emissivity Correction 8 pre define level and Variable from 0 01 to 1 0 STORAGE OF I...

Страница 15: ...3 74 1 D S measure 1 IFOV measure is the spot size needed to provide an accurate temperature measure Typically D S measure is 2 to 3 times smaller than D S theoretical which means the temperature mea...

Страница 16: ...02 2 F de 34 a 39 C La c mara de im genes t rmicas viene calibrada de f brica con una fuente de referencia de temperatura de cuerpo negro No es necesario realizar una calibraci n in situ Cumple con lo...

Страница 17: ...pec fico de uso deben determinar la importancia de cualquier caso de fiebre o temperatura elevada seg n la medici n de la temperatura en la piel por termograf a La c mara de im genes t rmicas se debe...

Страница 18: ...por mucho tiempo encender la linterna led Si presiona el bot n por mucho tiempo otra vez apagar la linterna led PREPARACI N DE LA PERSONA A EXAMINAR La persona que opera el sistema de diagn stico por...

Страница 19: ...e flecha hacia arriba 4 Bot n de encendido y para volver 5 Bot n de flecha hacia abajo 6 Tapa de la bater a 7 Fijaci n de la cuerda de seguridad 8 Linterna led 9 Lente para im genes IR 10 Disparador 1...

Страница 20: ...r de nivel de carga de la bater a 3 Lectura de puntos de temperatura de calor 4 Lectura de puntos de temperatura de fr o 5 Punto de mira medio 6 Punto de mira de temperatura de fr o 7 Punto de mira de...

Страница 21: ...equipo hacia la zona o el objeto que le interesa y observe la imagen t rmica La temperatura relativa est representada por colores de caliente a fr o La lectura de la temperatura media de gran tama o...

Страница 22: ...I N DE TEMPERATURA ELEVADA EN LA PIEL Si desea utilizar el term grafo para la detecci n de temperatura elevada en la piel aseg rese de que el modo de detecci n del men Measure Medir est activado El mo...

Страница 23: ...Thermview instalada 1 Presione el bot n OK Aceptar para ingresar al men Settings Ajustes 2 Presione el bot n de la flecha hacia abajo para acceder al men Setup Configuraci n 3 Presione el bot n OK Ac...

Страница 24: ...TOOTH 1 Presione el bot n OK Aceptar para ingresar al men Settings Ajustes 2 Presione el bot n de la flecha hacia abajo para acceder al men Setup Configuraci n 3 Presione el bot n OK Aceptar para ingr...

Страница 25: ...esta opci n El color del valor seleccionado cambiar a C en negro 3 Use el bot n RIGHT MENU DERECHA MEN para alternar entre C F y k use el bot n ESC OK SALIR ACEPTAR para salir del estado de enfoque y...

Страница 26: ...endurece configurar a la emisividad a 0 94 consulte el gr fico que figura a continuaci n para que la medici n sea lo m s precisa posible Substance missivit thermique Substance missivit thermique Aspha...

Страница 27: ...00 en incrementos de 10 Apagado autom tico presione el bot n OK Aceptar para seleccionar esta opci n Use los botones de flecha hacia arriba o abajo para configurar el per odo de tiempo despu s del cua...

Страница 28: ...memoria INFORMACI N Presione el bot n OK Aceptar para ingresar al men Information Informaci n Este men muestra la versi n del hardware y del software del term grafo FECHA Y HORA Presione el bot n OK...

Страница 29: ...seleccionar la imagen previa o la siguiente 2 Presione cualquier otra tecla para salir del modo Image Browser Explorador de im genes 1 Nombre de archivo de la imagen actual 3 2 rea de visualizaci n de...

Страница 30: ...MEDICIONES Fot metro Punto medio Detecci n autom tica de fr o o calor Marcadores autom ticos de fr o o calor Correcci n de emisividad Ocho niveles predefinidos y vari ables de 0 01 a 1 0 ALMACENAMIENT...

Страница 31: ...ra proporcionar una medici n precisa de la temperatura Por lo general la medici n de D S es de 2 a 3 veces menor que el D S te ri co Esto significa que la zona de medici n de la temperatura del objeti...

Отзывы: