Viewing the Test Results
Upon completion of the test, the YELLOW JACKET 37865 will display a
screen like that shown in
Figure 10
or
Figure 11
.
Selecting “OFF”
to power down the device, “PRINT” to print the results or “OK” to
return to the Select Refrigerant Screen shown in
Figure 3.
If the refrigerant tested is 98.0% pure or better, the refrigerant
is deemed suitable for standard recovery and reuse. Should the
refrigerant be less than 98.0% pure, the refrigerant is not suitable
for standard recovery and should not be reused. In either case,
disconnect the hose f
rom the vehicle and press either “OK” to return
to the calibration mode or “OFF” to turn the instrument off.
3
M
AINTENANCE
&
T
ROUBLESHOOTING
3.1
Changing the Sample Hoses
If the instrument displays an error or discoloration appears in the
sample hose near the service coupler, the sample hose should be
replaced.
R134: 1.7
R1234: 98.3
R22: 0.0
HC: 0.0
UNK: 0.0
AIR: 1.5
OFF PRINT OK
R134: 98.0
R12: 0.0
R22: 0.0
HC: 2.0
UNK: 0.0
AIR: 1.0
OFF PRINT OK
Figure 10
Figure 11