Mounting

The rack chassis is designed to fit into any standard 19” equipment rack 

enclosure. If used with the low profile fiber yellobriks 1RU of rack space 

is needed, if a taller yellobrik is to be accommodated then 3RU of space 

will be required. 

Chassis Use

Any yellobrik can be mounted into the chassis and secured firmly in 

place with the mechanical mounting brackets provided. Power is taken 

from the central power bus which plugs into the module. A space is 

reserved on the right hand side to allow front side connection to pass 

into the rear of the equipment rack for cable routing. Bracket use is 

shown below:

External Power Connections

The chassis is equipped with two external power connectors, one for 

primary power and a second for redundant power (if needed). The 

connectors are located on the rear of the chassis. If supplying your own 

power use a Molex MiniFit Series 5557 connector. Power should be 

12VDC and between 5A and 10A should be available to accommodate 

a full compliment of yellobriks. Connector wiring is shown below (view 

is looking INTO the power connector on the chassis, and wiring for the 

primary and redundant connectors is identical).

Insert module into rack. 

Partially screw one of 

the supplied brackets 

into the mounting hole 

(where shown). Position 

the bracket to clamp 

the module into place 

and then tighten.

Module Power

The chassis has a integrated 

central power bus, with a 

connector provided for 

each of the 14 slots.

Power Alarms

The chassis is equipped with external alarm GPO connections on the 

front of the rack, as well as power present LED indication. In the event 

of a supply failure the transition to the redundant backup is seamless, 

and will trigger an external alarm GPO which can be connected to an 

external alarm system.  In the event of a power failure a contact 

closure is provided across the connections shown below: