NeoGate TA FXS Gateway Quick Installation Guide
http://www.yeastar.com 8/12
3. NeoGate TA Series Installation
To avoid unexpected accident, personal injury or device damage, please read the following instructions
before installing the Gateway.
3.1 Placement Instructions
Ambient Temperature: to avoid overheating, please do not run NeoGate TA Series in the place where
the ambient temperature is above 122°F (50°C).
Ventilation: please make sure that the device has good ventilation around.
Anti-jamming: there may be some sources of interference that might affect the normal running of the
Gateway. It’s highly recommended that the device
Should be placed away from high-power radio, radar transmitters and high frequency, and
high-current devices.
Is using independent power junction box and effective anti-grid interference measures have been
taken.
Mechanical load: Please make sure that the device is placed steadily to avoid any accident that might
cause damage. If placed on the desktop, please ensure it is horizontally placed.
3.2 Installation Instructions
After placing the Gateway in a suitable place, please connect the power adapter and all other cables to
complete the installation.
3.2.1 Connection of Ethernet Ports
NeoGate TA Series provides one 10/100M adaptive RJ45 Ethernet LAN port.
LAN Port Connection
Connect one end of a network cable to the LAN port of the Gateway, and the other end to any port of
company’s LAN switch/router.
If the LAN port is connected to PC directly (not via a switch), please use cross-over cable.
3.2.2 Connection of FXS Ports
NeoGate TA FXS Gateways are available with 5 models, supporting up to 32 FXS ports.
RJ11 Phone Port
Connect one end of a RJ11 phone cable to the port. Connect the other end to your analog telephone.
RJ21 Connection:
applicable to NeoGate TA1600/2400/3200.
Connect one end of a RJ21 cable to the connector. Connect the other ends to your analog telephones.