Network Settings
DHCP
You can configure the base station to obtain network settings in one of the following
ways:
5
Easy Registration:
Normal Registration:
Handset Registration
You can register up to 8 handsets to one W60B base station. Each handset can be
registered to 4 different base stations.
When the handset LCD screen prompts “Press base paging 2s then press Reg.”, long
press on the base station till the registration LED flashes. There are two methods
to register a new handset:
1.Press the
OK
soft key on the handset, and then select
Register Handset
.
2.Select the desired base station and then press the
OK
soft key. The handset begins
searching the base station.
3.Press the
OK
soft key after searching a base station successfully.
4.Enter the base station PIN (default: 0000), and then press the
Done
soft key to
complete registration.
1.Press the
Reg
soft key on the handset to register quickly.
To register to multiple base stations, press the
OK
to enter the main menu, and select
Settings
->
Registration
->
Register Handset
, then repeat steps 2-4.
Note:
If the handset is registered to the base station successfully, the handset LCD
screen prompts “Handset Subscribed” and “Base NO.”( last 4 characters indicate
the base station’s MAC address).
If the handset LCD screen prompts “Searching for Base”, check if your base
station is powered on or not.
By default, the base station attempts to contact a DHCP server in your network to
obtain the valid network settings, e.g., IP address, subnet mask, gateway address and
DNS address.