background image

Chrono-Tester User Manual 

v1.2 

www.the-YCG.com

 

OPERATING INSTRUCTIONS 

 

Pulse Detection: 

1)  Power up the Chrono-Tester and place unit in Track Mode. 
2)  Connect output of chronograph light screens to Start Out & Stop Out inputs on Tester. 
3)  Connect the Start In & Stop In inputs of Tester to output of chronograph. 
4)  When a pulse is detected on either the Start or Stop input channels the corresponding 

blue LED will illuminate on the Tester.   

5)  Since the Tester is connected in series as a pass thru device the Tester can remain 

connected and not affect the operational accuracy of the ballistic chronograph setup. 

6)  Press Reset button to clear the LEDs. 

 

Testing Cables: 

1)  Power up the Chrono-Tester and place unit in Test Mode. 
2)  Connect cable to be tested to the Tester Start In and Start Out inputs. 
3)  Press the Pulse Out button; the Tester will output a test pulse on the Start Out and if the 

Start In receives the pulse, the Blue Start LED will illuminate.   

4)  Press Reset to clear the LED. 
5)  A second cable can be tested simultaneously on the Stop In & Stop Out as well. 

 

 