background image

 
 
 
 
 

Please read this manual thoroughly for the instruction of correct usage before using this product and keep this 
manual as a reference. 

 

   

l

 

Before cleaning the controller, please ensure that the power is switch off.   

l

 

Please remove stains on the display panel by using a soft cloth only.   

l

 

No scrubbing or touching the display panel with any hard object, the display panel can be easily scratched. 

l

 

Do not press any button on the display panel using pointy objects such as ballpoint pen or screw driver, it 
can easily scratch the panel or damage buttons on the panel. 
 

 
 

Please  confirm  the  product  you  received  is  in  full  agreement  with  the  model  that  you  selected  according  to  the 
following codes: 
 
 

Panel Dimensions

mm

     

D:96

×

96      F:96

×

48 

E:72

×

72      G:48

×

48 

 T

ype of Display 

6: Double rows display 

Type of control action

 

0: On-off action Relay        3: Time proportion action     

4: On-off PID action with auto-tuning             

7: Single phase zero-across pulse PID action with auto-tuning 

On

-off position Alarm     

0: No alarm    1: High alarm         

 

 

Type of Input

 

1: Thermocouple signal 

2: Thermo-resistance signal (RTD input) 

Type of Output         

 

No: Relay contact (Maximum 3A)       

V: Logic output for SSR 

A: Relay contact (Maximum 16A) 

B: Relay contact (Maximum 16A) 

Type of ca

libration 

Lower limit of the span

 

Upper limit of the span

 

 

 

 

2.1 Caution when installing 

Please install the controller under the following conditions: 

l

 

Temperature: 0 to 50 degrees C. 

l

 

Humidity: 45% to 85% RH. 

l

 

Atmospheric pressure: 86 to 106kPa 
 

Please avoid the following conditions during installation: 

l

 

Rapid temperature changes, leading to dew condensation. 

l

 

Corrosive gases (especially sulfide gas, ammonia, etc.) or flammable gases. 

l

 

Direct vibration or shock 

l

 

Contact with water, oil, chemicals, steam , smoke, or hot water 

l

 

High concentrations of atmospheric dust, salt or iron particles 

l

 

Large inductive interference, resulting in static electricity, magnetic fields or noise. 

l

 

Direct sunlight. 

l

 

Radiant heat sources, etc 

2.2 Mounting Process   

   

1

Cut out rectangle holes on the panel for installing the controller according to the required hole size.                                           

When installing more than one controller, the minimum horizontal and vertical distance between two holes should be 25mm 
and 30mm respectively.                             

2

Insert the controller into the hole on the panel.                                                               

3

Insert mounting bracket in the slot for mounting the controller.                                                                                 

4

Push the mounting bracket tightly to connect the instrument and the panel firmly 

 

2.3 Dimension 

in millimeters

   

                                                                   

 

                        H          h 

Model 

H

×

h

×

b

×

h

×

b

 

 

ND 

96

×

96 

92

×

92

×

70 

(92+1)

×

(92+1) 

          B                                    L 

NE 

72

×

72 

68

×

68

×

70 

(68+1)

×

(68+1) 

          b                                              b' 

NF 

96

×

48 

92

×

44

×

70 

(92+1)

×

(44+1) 

                                           

 

NG 

48

×

48 

44

×

44

×

100 

(44+1)

×

(44+1) 

                                            h' 

 

 

 

 

 
 
 

3

1

 

Wiring cautions 

1

 

For thermocouple input, use the specified compensation wire. 

2

 

For RTD input, use leads with low resistance and having no resistance differences among the 3 leads. 

3

 

Conduct input signal wiring away from instrument power, electric equipment power and load lines to   

avoid noise induction. 
 

3

2

 

Terminals' configuration 

1

Terminals for Model:                                                       

2

Terminals for Model (with SSR): 

 

    

ND/F/E-6011, 6311, 6411, 6012, 6312, 6412

          

ND/F/E-6401V, 6401V, 6302V, 6402V

 

 

 

 

 

 

 

 

 

 

 

                                                                          

 