output control

 

  

Press

"▲",

modify 

single digit as 
following :

→ →

 

Please refer to Table 3 for details of 

、 、 、

⑹ 

    

 

output 

control with 

mono-stable 

time 

 

Press  the  "

"  key  to 

select the digits need to 
be  modified  until  it 
flashes, then press the "

"key  to  modify  the 

value

 

Unit is second, the range of delay can select from 0-99.9s. 
Note: this function is only available if the control output is 

  or 

. For 

  or 

, this function is not available. 

 

 

Step 3

  ⑺

 

Exiting the 

function 

parameter 

setting mod

After the preset value is set and verified according to the Step 1 and Step 2, the press the “preset/parameter” 

3s 

again,  the  counter  will  automatically  exit  the  parameter  setting  mode  and  enter  the  counting  mode,  and  the  preset 
indicator will be off. If the parameter is not modified, the counter will remain in existing conditions. If the parameter 
is modified, the counter will reset to zero and the modified parameters are saved and restart with new parameters.   

 

TALBE 3: Output Action 

                                                                           

 

Output 

Increase  

Decrease  

Action after reaches preset value 

 

RST 
SET 
 

OUTPUT

 

RST 
SET 
   

OUTPUT

 

When RST is set to low level(L), it will be reset, all digital display 
reset to 0

contact opens

RST is set to high level(H), meter starts 

counting .When the meter counting value reaches preset value

the 

contact output is emitted and counting keeps operating until RST is 
in reset status

 

 

RST 
SET  
 

OUTPUT

 

RST 
SET 
   

OUTPUT

 

When RST is set to low level(L), it will be reset, all digital display 
reset to 0

contact opens

RST is set to high level(H), meter starts 

counting .When the meter counting value reaches preset value

the 

contact  output  is  emitted  and  counting  stops  until  RST  is  in  reset 
status

 

 

RST 
SET 
 

OUTPUT

 

RST 
SET 
 

OUTPUT

 

When RST is set to low level(L), it will be reset, all digital display 
reset to 0

contact opens

RST is set to high level(H), meter starts 

counting .When the meter counting value reaches preset value

the 

contact output is emitted and the contact output releases when the 
mono-stable delay is ended.

 

 

RST 
SET 
 

OUTPUT

 

RST 
SET 
 

OUTPUT

 

When RST is set to low level(L), it will be reset, all digital display 
reset to 0

contact opens

RST is set to high level(H), meter starts 

counting .When the meter counting value reaches preset value

the 

contact output is emitted, counting stops and the contact output 
releases when the mono-stable delay is ended. 

NOTE:    

mono-stable time delay output

(0

~

99.9seconds set)        

MAINTAIN ITS OWN STATUS WITH OUTPUT 

 

Additional Information   

1. Please wiring according to terminals wiring diagram on the meter 
case strictly and ensure the actual power supply is consistent with 
the rating value.   
2. The connection of sensor and counter must be robust. The signal 
lines shall not be placed parallel with the power lines of electric 
supply and control lines. 
3 please select the sensor reasonably according to requirement and 
wiring correctly. 
(1) For NPN kind sensor (negative pulse input) or contact counting 
signal, the wiring method is shown as Figure 1. 

 

(2) For PNP kind sensor (positive pulse input), the wiring method 

is shown as following 

(0V)

 

 

 

 

 

Contact

Input

+12V

CP1

COM

Control

Circu it

NPN  SENSOR

 

+12V

 

 

CP2

 

COM

 

 

 

Contact

Input

Control

Circu it

PNP  SENSOR

 

 

 

 

4. COM terminal is not only public GND

but also output power 

supply 0V terminal. 
5. For contact sensors, please select low speed (0 – 25Hz) frequency 
6. After power is connected, by selecting the required counting 
frequency, the counter will enter the normal counting mode. 

 