SAFETY INSTRUCTIONS

•   If  the  carbon  brushes  need  to 

be replaced, have this done by a 

qualified repair person (always 

replace the two carbon brushes at 

the same time).

ASSEMBLY

Starting to use the lawnmower

Power connection

Do not switch on the unit until it has 

been completely assembled. Before 

switching on the tool, always check the 

connection cable for signs of damage; 

only an undamaged connection cable 

may be used. Damaged connection 

cables are highly dangerous!

The electrical data of the electrical 

supply must be the same as that 

indicated in the rating plate of this 

tool. Please do not use the tool if the 

electrical data is different.

•   Insert  the  main  plug  of  the 

unit connection cable into the 

combined switch/plug

•   Secure  with  the  cable  grip.  The 

loop of the mains cable must be 

long enough for the cable grip to 

slide from one side to the other.

Switching ON and OFF

•   Switching on: press the button on 

the combined switch/plug. Hold 

down the ON button and pull the 

switch bar towards the handle and 

hold in position

• Switching off: release the switch bar

WARNING:

 When the motor has been 

switched off, the cutter continues to 

run for several seconds. Therefore, 

do not touch the underside of the 

mower until the cutter has come to a 

standstill.

Preparation

•   While  mowing,  always  wear 

suitable footwear and long 

trousers.

•   Do not operate the appliance when 

barefoot or wearing open sandals.

•   Thoroughly inspect the area where 

the appliance is to be used and 

remove all stones, sticks, wires, 

bones, and other foreign objects.

•   Before use, always inspect visually 

to see if the blades, blade bolts, 

and cutter assembly are not worn 

or damaged. Replace worn or 

damaged blades and bolts in sets 

to preserve balance.

•   On  multi-bladed  appliances,  take 

care as rotating one blade can 

cause other blades to rotate.

•   The appliance should by supplied 

via a residual current device (RCD) 

with a tripping current of not more 

than 30 mA

•   Be  careful  during  adjustment  of 

Содержание YT5139

Страница 1: ...TEL 0573 83225888 503 Http www yattool com CH138 8458 513900X019 071 A5 148 5x210mm 70g 10 A4 QQ 99739279 2021 11 20 Adobe Acrobat 7 Pro...

Страница 2: ...aducereainstruc iunilororiginaleMa in Electric DeTunsIarba3Ro I OriginalInstructionsElectricLawnmower YT5139 1000W Electric De Tuns Iarba 1000W Electric Lawnmower RO EN Manualasamblare utilizare ntre...

Страница 3: ......

Страница 4: ...3 A x1 B x1 C x1 D x1 E x2 F x2 G x2 H x2 I x1 30 PH 3 RO EN Ansamblu Assembly...

Страница 5: ...pecta i Observe Conectat Connected Neconectat Not connected Scoatere de sub tensiune Power off Punere sub tensiune Power up Cur are Cleaning Mentenan Maintenance Corect Correct Incorect Incorrect manu...

Страница 6: ...5 E x2 G x2 I 1 2 5 RO EN Ansamblu Assembly...

Страница 7: ...6 F 3 4 6 RO EN Ansamblu Assembly...

Страница 8: ...7 H x2 PH 1 2 Click Click B C 5 6 7 RO EN Ansamblu Assembly...

Страница 9: ...8 2 3 1 Click Click D 1 2 3 7 8 8 RO EN Ansamblu Assembly...

Страница 10: ...9 3 2 1 20mm 40mm 60mm A 1 B 1 A 2 B 2 A 3 B 3 A B 1 2 3 1 2 3 1 2 9 RO EN utilizare Use...

Страница 11: ...10 3 1 2 2 1 3 4 10 RO EN utilizare Use...

Страница 12: ...11 1 2 3 1 2 5 6 11 RO EN utilizare Use...

Страница 13: ...12 1 2 7 8 12 RO EN utilizare Use...

Страница 14: ...13 1 3 2 1 2 13 RO EN ntre inere Maintenance...

Страница 15: ...14 3 4 14 RO EN ntre inere Maintenance...

Страница 16: ...15 5 6 15 RO EN ntre inere Maintenance BYT5139 8231 513901 25 30N m...

Страница 17: ...16 1 2 16 RO P strare pe perioada iernii EN Winter storage...

Страница 18: ...rsoaneleprezenteladistan ntimp ce utiliza i ma ina Feri i v de lamele ascu ite Lamele continu s se roteasc dup oprirea motorului Deconecta i techeruldelare ea nainte de efectuarea ntre inerii sau n ca...

Страница 19: ...timp ce se afl n apropiere alte persoane mai ales copii sau animalede companie Operatorul sau utilizatorul este responsabil pentru accidentele sau pericolele prezentate pentru alte persoane sau propr...

Страница 20: ...riculoase Datele aliment rii electrice trebuie s coincid cuceleindicatepepl cu ade valori nominale a acestui aparat Nu utiliza i aparatul dac datele electrice sunt diferite Introduce i techerul cablul...

Страница 21: ...solutnecesar i ridica i numai partea care este la distan de operator Asigura i v ntotdeauna c ambele m ini sunt npozi ie de operare nainte de a repune aparatul pe sol trebuie utilizat aparatul i ndep...

Страница 22: ...ns gazonul cilindrice ave i grij in timpul regl rii aparatului pentru a impiedica prinderea degetelor intre lamele mobile i piesele fixe ale aparatului In cazul ma inilor de tuns gazonul rotative asig...

Страница 23: ...Cablul prelungitor techerul i priza trebuie s fie de tip impermeabile la ap i destinate utiliz rii la exterior L sa i intotdeauna ma ina s se r ceasc inainte de depozitare Cand vre i s depozita i apa...

Страница 24: ...23 RO DESCRIEREA PRODUSULUI 1 6 5 2 3 4 1 Bar de ac ionare 2 Buton ntrerup tor 3 Buton 4 Colector de iarb 5 Capac motor 6 Ro i...

Страница 25: ...aceasta func ioneaz n gol pe l ng timpul de declan are Model YT5139 Tensiune nominal 220 240V 50 Hz Putere nominal consumat 1000W Vitez nominal f r sarcin 3400 min L ime de t iere 320mm Nivel garanta...

Страница 26: ...r din cauza prezen ei substan elor periculoase Problem Solu ie Motorul nu func ioneaz Verifica i cablul electric i ntrerup torul de circuit siguran a ncepe i s tunde i iarb scurt pe o suprafa care a f...

Страница 27: ...26 RO VEDERE N SPA IU I LISTA PIESELOR COMPONENTE...

Страница 28: ...urubfiletantflan 18 Arc 32 11 urubstator 1 9 Cabluconexiune 19 Puntefa 32 12 aib elastic 1 10 Comutator 20 Panoudeghidare aierbii 32 13 Garnitur plat 1 11 Comutatordeclan are 21 Carcas 32 14 Piuli he...

Страница 29: ...andardele EN 60335 1 2012 A11 2014 A13 2017 A1 2019 A14 2019 A2 2019 EN 60335 2 77 2010 EN 62233 2008 EN IEC 55014 1 2021 EN IEC 55014 2 2021 EN IEC 61000 3 2 2019 A1 EN 61000 3 3 2013 A1 IEC 62321 3...

Страница 30: ...objects and or debris when using the machine keep bystanders away Beware of sharp blades Blades continue to rotate after the motor is maintenance or if cord is damaged cutting means Wear ear protectio...

Страница 31: ...r accidents or hazards occurring to other people or their property This tool must be only for cutting grass in your garden Do not use it in public parks stadiums or forests Anyusecontrarytothisinstruc...

Страница 32: ...g ON and OFF Switching on press the button on the combined switch plug Hold down the ON button and pull the switch bar towards the handle and hold in position Switching off release the switch bar WARN...

Страница 33: ...liance starts to vibrate abnormally check immediately Maintenance and storage Keep all nuts bolts and screws tight to be sure the appliance is in safe working condition the machine to prevent the fing...

Страница 34: ...s be aware that even though the power source is switched off the blades can still be moved Only use approved cables Extensions cables should be only used if they comply with H05VV F H05RN F types or I...

Страница 35: ...34 EN KNOW YOUR PRODUCT 1 6 5 2 3 4 1 Switch bar 2 Switch button 3 Knob 4 Grass collection box 5 Motor cover 6 Wheels...

Страница 36: ...estimation of exposureintheactualconditionsofuse takingintoaccountallpartsoftheoperatingcyclesuchasthetimes Model YT5139 Rated voltage 220 240V 50 Hz Rated input power 1000W Rated no load speed 3400 m...

Страница 37: ...angerous for the environment and human health due to the presence of harmful substances Problem Solution Motor does not run Check mains connection cable and circuit breaker fuse Start on short grass o...

Страница 38: ...37 EN EXPLODED VIEW WITH PARTS LIST...

Страница 39: ...18 Spring 32 11 Statorscrew 1 9 Connectingwire 19 Frontaxle 32 12 Springwasher 1 10 Switch 20 Grassguideboard 32 13 Flatgasket 1 11 Switchtrigger 21 Housing 32 14 Hexagonnut 1 12 Brakeleverspring 22 P...

Страница 40: ...orms with the norms Name and address of the person Richie PERMAL Supplier Quality Leader Authorized representative of Julien Ledin ADEO Quality Leader T V Rheinland LGA Products GmbH Serial No Please...

Страница 41: ...ADEO Services 135 Rue Sadi Carnot CS 00001 59790 RONCHIN France 17 04201 141031 1 Made in P R C 2019 N de s rie Serial No 203384 01 111016 01 000000...