Follow these sub-steps to connect the READY pendant communication, power, and safety wiring.
You will route the READY pendant flying leads to the destinations in this table.
Pendant Flying Leads
Destination Terminal
Function
Brown
FSU Breakout - 21
Three-Position Enabling Switch Circuit 1
Yellow
FSU Breakout - 22
Three-Position Enabling Switch Circuit 1
Green
FSU Breakout - 23
Three-Position Enabling Switch Circuit 2
Grey
FSU Breakout - 24
Three-Position Enabling Switch Circuit 2
Pink
Power Supply (+24V)
+24V DC
Green/Brown
FSU Breakout - 5
Emergency Stop Circuit 1
White/Green
FSU Breakout - 6
Emergency Stop Circuit 1
Grey/Pink
FSU Breakout - 7
Emergency Stop Circuit 2
Red/Blue
FSU Breakout - 8
Emergency Stop Circuit 2
Black
Power Supply (0V)
0V DC
Violet
FSU Breakout - 25
Key Switch Circuit 1
White/Pink
FSU Breakout - 26
Key Switch Circuit 1
White
FSU Breakout - 27
Key Switch Circuit 2
Blue
FSU Breakout - 28
Key Switch Circuit 2
White/Blue
N/A
Not Connected
Connect the READY pendant's Ethernet cable to the IPC. You may connect the pendant through an
Ethernet switch to increase the number of Ethernet ports.
a
Connect the pendant's power leads to a 24V DC, 2.5A source. Connect the Pink wire to +24V and the
Black wire to 0V.
b
Connect the remaining safety I/O leads to your control panel or safety cabinet. Make your own cable/
wiring for the 12 safety signals long enough to reach their destinations in the table. Include ferrules at the
end of your wiring to insert in the terminal blocks.