background image

YASKAWA ELECTRIC AMERICA, INC.

Chicago-Corporate Headquarters

   2942 MacArthur Blvd. Northbrook, IL 60062-2028, U.S.A.

Phone: (847) 291-2340   Fax: (847) 291-4203   Internet: http//www.yaskawa.com

Chicago-Technical Center

   3160 MacArthur Blvd. Northbrook, IL 60062-1917, U.S.A.

Phone: (847) 291-0411   Fax: (847) 291-1018

MOTOMAN INC.

805 Liberty Lane West Carrollton, OH 45449, U.S.A.

Phone: (513) 847-6200   Fax: (513) 847-6277

YASKAWA ELETRICO DO BRASIL COMERCIO LTDA.

Avenida Brigadeiro Faria Lima, 1664-5° Andar, CJS 504/511 CEP 01452-001 - Sao Paulo-SP, Brasil

Phone: (011) 815-7723   Fax: (011) 210-9781

YASKAWA ELECTRIC EUROPE GmbH

Am Kronberger Hang 2, 65824 Schwalbach, Germany
Phone: (49) 6196-569-300   Fax: (49) 6196-888-301

Motoman Robotics AB

Box 130 S-38500. Torsas, Sweden

Phone: 0486-10575   Fax: 0486-11410

Motoman Robotec GmbH

Kammerfeldstra

?

e 1, 85391 Allershausen, Germany

Phone: 08166-900   Fax: 08166-9039

YASKAWA ELECTRIC UK LTD.

3 Drum Mains Park Orchardton Woods Cumbernauld, Scotland, G68 9LD, U.K.

Phone: (1236) 735000   Fax: (1236) 458182

YASKAWA ELECTRIC KOREA CORPORATION

Paik Nam Bldg. 901 188-3, 1-Ga Euljiro, Joong-Gu, Seoul, Korea

Phone: (02) 776-7844   Fax: (02) 753-2639

YASKAWA ELECTRIC (SINGAPORE) PTE. LTD.

Head Office:

 CPF Bldg. 79 Robinson Road #13-05, Singapore 0106, SINGAPORE

Phone: 221-7530   Telex: (87) 24890 YASKAWA RS   Fax: 224-5854

Service Center:

 221 Henderson Road, #07-20 Henderson Building Singapore 0315, SINGAPORE

Phone: 276-7407   Fax: 276-7406

YATEC ENGINEERING CORPORATION

Shen Hsiang Tang Sung Chiang Building 10F 146 Sung Chiang Road, Taipei, Taiwan

Phone: (02) 563-0010   Fax: (02) 567-4677

SHANGHAI OFFICE

   Room No. 8B Wan Zhong Building 1303 Yan An Road (West), Shanghai 200050, CHINA

Phone: (86) 212-1015   Fax: (86) 212-1015

TAIPEI OFFICE

   Shen Hsiang Tang Sung Chiang Building 10F 146 Sung Chiang Road, Taipei, Taiwan

Phone: (02) 563-0010   Fax: (02) 567-4677

TOKYO OFFICE

   8th Floor, New Pier Takeshiba South Tower, 1-16-1, Kaigan, Minato-ku, Tokyo, 105, Japan

Phone: (03) 5402-4542   Fax: (03) 5402-4588   Internet: http//www.yaskawa.co.jp

Yaskawa Electric America, Inc., November, 1996

YEA-TOA-C736-40.23 Printed In U.S.A.

Содержание VS-616PC5 Series

Страница 1: ...VS 616PC5 P5 Option Instruction Manual Isolated 4 20mA Output Monitor Card CM B2 P ...

Страница 2: ...minate the possibility of static charge if present affecting the card Failure to observe this precaution may result in equipment damage NOTICE Printed November 1996 The information contained within this document is the proprietary property of Yaskawa Electric America Inc and may not be copied reproduced or transmitted to other parties without the expressed written authorization of Yaskawa Electric...

Страница 3: ... option card please specify the inverter model and code number Description NAME CODE NUMBER FUNCTIONS Isolated Monitor Card CM B2 P 73600 DO12X Converts analog monitor signals 0 to 10V to isolated signals 0 to 10V 4 to 20mA or 0 to 20mA CM B2 P 73600 DO120 Grounding lead wire connected to terminal E G of inverter control board E Terminal block TB1 for isolated signal output Analog monitor signals ...

Страница 4: ...cated on each side of the cover and lift the cover upward from the rear of the cover Refer to the VS 616PC5 P5 User s Manual YEA TOA S616 12 if necessary 5 Check that the indicator CHARGE LED is OFF indication that power is OFF 6 Place the Isolated Monitor Card onto the four 4 stand off posts in the control board aligning the Isolated Monitor Card s connector with the control board s 2CN connector...

Страница 5: ... 2 Installation of Isolated Monitor Card CM B2 P Connector terminal FRONT VIEW CM B2 P SIDE VIEW Stand Off Posts 4 CM B2 P TB1 TB2 1 HDR1 GND 73600 D0120 CODE NO TP1 Refer to Fig 3 1 1 1 12 S1 S2 AM AC S3 Fig 3 Output Signal Configuration 3 6 9 2 5 8 1 4 7 JUMPER for HDR1 HDR1 3 6 9 2 5 8 1 4 7 HDR 1 Configures Output Signal at TB1 Note The three jumpers on the HRD1 are used to configure the outpu...

Страница 6: ...gnals Connect the wire as shown in Fig 5 to prevent noise interference Failure to observe these precautions may result in equipment malfunctions L1 R L2 S L3 T IM U T1 V T2 W T3 VS 616 PC5 P5 E G AC AM 2 1 2CN 2CN E Isolated Monitor Card CM B2 P Fig 4 Interconnection Diagram 250 P Current Output TB1 TP1 TB2 12 CAUTION Shielded Sheath Armor Fig 5 Shielded Wire B C A A NEVER connect the wire s shiel...

Страница 7: ...re as listed in the following table Stripping TB1 and TB2 Wires for Connection The following figure shows the correct length of insulation to be stripped in order to connect the wire to terminal blocks TB1 and TB2 Cable Selection 1 Cable that is too heavy exerts pressure on the option card and may cause failure 2 Cable too thin may cause a poor connection or may prematurely break External Function...

Страница 8: ... Woods Cumbernauld Scotland G68 9LD U K Phone 1236 735000 Fax 1236 458182 YASKAWA ELECTRIC KOREA CORPORATION Paik Nam Bldg 901 188 3 1 Ga Euljiro Joong Gu Seoul Korea Phone 02 776 7844 Fax 02 753 2639 YASKAWA ELECTRIC SINGAPORE PTE LTD Head Office CPF Bldg 79 Robinson Road 13 05 Singapore 0106 SINGAPORE Phone 221 7530 Telex 87 24890 YASKAWA RS Fax 224 5854 Service Center 221 Henderson Road 07 20 H...

Отзывы: