3.2 Commissioning
CAUTION!
–
Before commissioning the device must be brought to room tempera-
ture.
–
At condensation the device must be absolutely dry before connected
to power.
–
To avoid overheat during operation the device must not be laid open
to direct sun light.
–
After opening the control cabinet or desk, there are parts with pos-
sible dangerous voltage available.
–
For all signal connections only screened cables are permitted.
–
Signal cables must not be let within the same cable shaft as high
voltage cables.
3.2.1 VIPA Startup-Manager
As soon as the Touch Panel is provided by power supply the Touch Panel starts with the
user area
of the
VIPA Startup Manager
.
On delivery the button [Advanced] is shown on the starting screen. Further buttons and
their properties can be configured in the administrator area with the button [Settings] or
freely programmed by means of an XML editor in the file startup.xml in the direc-
tory
‘StartupMngr
è
flashdisk’
.
The file startup.xml can be found under
‘StartupMngr
è
flashdisk’
. By means of an XML
editor the Startup Manager can be individually adapted.
With clicking on [Advanced] the administrator area is opened. On delivery there are the
following buttons:
n
KuK Tools
n
Backup
n
Restore
n
Panel Info
n
Normal
n
Control Panel
n
Settings
n
Exit
To permanently store changes within the Registry after PowerOFF - PowerON the pro-
gram KuK Tools is to be used. The program can be executed by clicking on the button
[KuK Tools]. To permanently store the registry file click on the button [Store] under "Per-
manent Registry".
With [Backup] the files of the flash disk and the Registry settings can be stored.
The backed up files can be restored by [Restore].
User area
Advanced
Startup.xml
Administrator area
KuK Tools
Backup
Restore
VIPA HMI
Deployment Touch Panel
Commissioning > VIPA Startup-Manager